Cobalt hexacyanoferrate-modified electrode for amperometric assay of hydrazine

被引:0
|
作者
Ravi Shankaran D. [1 ]
Sriman Narayanan S. [1 ]
机构
[1] Department of Analytical Chemistry, University of Madras
关键词
Oxidation; Physical Chemistry; Graphite; Cobalt; Detection Limit;
D O I
10.1023/A:1020241011841
中图分类号
学科分类号
摘要
A graphite electrode modified with cobalt hexacyanoferrate by mechanical immobilization was used for amperometric determination of hydrazine. The modified electrode exhibits good catalytic activity for the oxidation of hydrazine at a reduced overpotential with remarkable sensitivity. The modified electrode showed a linear response for hydrazine in the concentration range of 2.0 × 10-5 to 2.8 × 10-4 M. The detection limit was 9.8 × 10-6 M (S/N = 3). The proposed modified electrode was simple, sensitive, rapid, stable and promising.
引用
收藏
页码:987 / 991
页数:4
相关论文
共 50 条
  • [1] Cobalt hexacyanoferrate-modified electrode for amperometric assay of hydrazine
    Shankaran, DR
    Narayanan, SS
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2002, 38 (09) : 987 - 991
  • [2] Electrode modified with cobalt hexacyanoferrate for amperometric determination of hydrazine
    Shankaran, D.R.
    Narayanan, S.S.
    Elektrokhimiya, 2002, 38 (09): : 1098 - 1103
  • [3] Hydrazine oxidation catalyzed by ruthenium hexacyanoferrate-modified glassy carbon electrode
    Costa, Wendell M.
    Marques, Aldalea L. B.
    Marques, Edmar P.
    Bezerra, Cicero W. B.
    Sousa, Eliane R.
    Cardoso, William S.
    Song, Chaojie
    Zhang, Jiujun
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (02) : 375 - 382
  • [4] Hydrazine oxidation catalyzed by ruthenium hexacyanoferrate-modified glassy carbon electrode
    Wendell M. Costa
    Aldaléa L. B. Marques
    Edmar P. Marques
    Cicero W. B. Bezerra
    Eliane R. Sousa
    William S. Cardoso
    Chaojie Song
    Jiujun Zhang
    Journal of Applied Electrochemistry, 2010, 40 : 375 - 382
  • [5] Electrocatalytic oxidation of hydrazine at cobalt hexacyanoferrate-modified glassy carbon, Pt and Au electrodes
    Golabi, SMI
    Noor-Mohammadi, F
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 1998, 2 (01) : 30 - 37
  • [6] Amperometric sensor for thiosulphate based on cobalt hexacyanoferrate modified electrode
    Shankaran, DR
    Narayanan, SS
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 86 (2-3) : 180 - 184
  • [7] Amperometric determination of thiosulfate at a surface-renewable nickel(II) hexacyanoferrate-modified carbon ceramic electrode
    Wang, P
    Yuan, Y
    Jing, XY
    Zhu, GY
    TALANTA, 2001, 53 (04) : 863 - 869
  • [8] Amperometric Sensor for Hydrazine Determination Based on Mechanically Immobilized Nickel Hexacyanoferrate Modified Electrode
    D. R. Shankaran
    S. S. Narayanan
    Russian Journal of Electrochemistry, 2001, 37 : 1149 - 1153
  • [9] Amperometric sensor for hydrazine determination based on mechanically immobilized nickel hexacyanoferrate modified electrode
    Shankaran, DR
    Narayanan, SS
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2001, 37 (11) : 1149 - 1153
  • [10] Amperometric determination of hydrazine at manganese hexacyanoferrate modified graphite-wax composite electrode
    Jayasri, D.
    Sriman Narayanan, S.
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 144 (1-2) : 348 - 354