Evaluation of thermo-mechanical and thermal behavior of full-scale energy foundations

被引:0
作者
Kyle D. Murphy
John S. McCartney
Karen S. Henry
机构
[1] University of Colorado Boulder,Department of Civil, Environmental, and Architectural Engineering
[2] 428,Department of Civil Engineering
[3] United States Air Force Academy,undefined
来源
Acta Geotechnica | 2015年 / 10卷
关键词
Deep foundations; Geothermal heat exchange; Thermal response test; Thermo-mechanical behavior;
D O I
暂无
中图分类号
学科分类号
摘要
Eight full-scale energy foundations were constructed for a new building at the US Air Force Academy. The foundations are being used to demonstrate this technology to the United States Department of Defense and have several experimental features in order to study their thermal–mechanical behavior. Three of the foundations are instrumented with strain gages and thermistors, and their thermo-mechanical response during a heating and cooling test was evaluated. For a temperature increase of 18 °C, the maximum thermal axial stress ranged from 4.0 to 5.1 MPa, which is approximately 25 % of the compressive strength of concrete (estimated at 21 MPa), and the maximum upward displacement ranged from 1.4 to 1.7 mm, which should not cause angular distortions sufficient enough to cause structural or aesthetic damage of the building. The end restraint provided by the building was observed to change depending on the location of the foundation. The heat flux per meter was measured by evaluating the temperatures and flow rates of a heat exchanger fluid entering and exiting the foundations. The heat flux values were consistent with those in the literature, and the foundation with the three continuous heat exchanger loops was found to have the greatest heat flux per meter. The transient thermal conductivity of the subsurface measured using the temperatures of the subsurface surrounding the foundation ranged from 2.0 to 2.3 W/mK, which is consistent with results from thermal response tests on energy foundations reported in the literature.
引用
收藏
页码:179 / 195
页数:16
相关论文
共 31 条
[1]  
Adam D(2009)Energy from earth-coupled structures, foundations, tunnels and sewers Géotechnique 59 229-236
[2]  
Markiewicz R(2012)Thermo-mechanical behaviour of energy piles Géotechnique 62 503-519
[3]  
Amatya BL(2009)Energy pile test at Lambeth College, London: Geotechnical and thermodynamic aspects of pile response to heat cycles Géotechnique 59 237-248
[4]  
Soga K(2006)Energy foundations and other thermo-active ground structures Géotechnique 56 81-122
[5]  
Bourne-Webb PJ(2008)Numerical and experimental assessment of thermal performance of vertical energy piles: an application Appl Energy 85 901-910
[6]  
Amis T(2007)Field performance of an energy pile system for space heating Energy Build 39 517-524
[7]  
Laloui L(2006)Experimental and numerical investigations of the behaviour of a heat exchanger pile Int J Numer Anal Methods Geomechan 30 763-781
[8]  
Bourne-Webb PJ(2012)Pile heat exchangers: thermal behaviour and interactions Proc ICE Geotechn Eng 166 178-196
[9]  
Amatya B(2012)Strain distributions in full-scale energy foundations DFI J 6 28-36
[10]  
Soga K(undefined)undefined undefined undefined undefined-undefined