Analysis of Bias in the Apparent Correlation Coefficient Between Image Pairs Corrupted by Severe Noise

被引:0
|
作者
Fredrik Bergholm
Jeremy Adler
Ingela Parmryd
机构
[1] KTH,Department of Numerical Analysis and Computer Science
[2] Stockholm University,The Wenner
关键词
Correction correlation coefficient; Severely degraded images;
D O I
暂无
中图分类号
学科分类号
摘要
The correlation coefficient r is a measure of similarity used to compare regions of interest in image pairs. In fluorescence microscopy there is a basic tradeoff between the degree of image noise and the frequency with which images can be acquired and therefore the ability to follow dynamic events. The correlation coefficient r is commonly used in fluorescence microscopy for colocalization measurements, when the relative distributions of two fluorophores are of interest. Unfortunately, r is known to be biased understating the true correlation when noise is present. A better measure of correlation is needed. This article analyses the expected value of r and comes up with a procedure for evaluating the bias of r, expected value formulas. A Taylor series of so-called invariant factors is analyzed in detail. These formulas indicate ways to correct r and thereby obtain a corrected value free from the influence of noise that is on average accurate (unbiased). One possible correction is the attenuated corrected correlation coefficient R, introduced heuristically by Spearman (in Am. J. Psychol. 15:72–101, 1904). An ideal correction formula in terms of expected values is derived. For large samples R tends towards the ideal correction formula and the true noise-free correlation. Correlation measurements using simulation based on the types of noise found in fluorescence microscopy images illustrate both the power of the method and the variance of R. We conclude that the correction formula is valid and is particularly useful for making correct analyses from very noisy datasets.
引用
收藏
页码:204 / 219
页数:15
相关论文
共 50 条
  • [31] Common Pediatric Cerebellar Tumors: Correlation between Cell Densities and Apparent Diffusion Coefficient Metrics
    Koral, Korguen
    Mathis, Derek
    Gimi, Barjor
    Gargan, Lynn
    Weprin, Bradley
    Bowers, Daniel C.
    Margraf, Linda
    RADIOLOGY, 2013, 268 (02) : 532 - 537
  • [32] Asymmetrical distribution of noise correlation between digital image and digital camera
    Cui X.-R.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (11): : 2467 - 2472
  • [33] Correlation of the apparent diffusion coefficient and the standardized uptake value in neoplastic lesions: a meta-analysis
    Shen, Guohua
    Ma, Huan
    Liu, Bin
    Ren, Pengwei
    Kuang, Anren
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (12) : 1076 - 1084
  • [34] Texture Analysis of Apparent Diffusion Coefficient Maps in Cervical Carcinoma: Correlation with Histopathologic Findings and Prognosis
    Yamada, Ichiro
    Oshima, Noriko
    Miyasaka, Naoyuki
    Wakana, Kimio
    Wakabayashi, Akira
    Sakamoto, Junichiro
    Saida, Yukihisa
    Tateishi, Ukihide
    Kobayashi, Daisuke
    RADIOLOGY-IMAGING CANCER, 2020, 2 (03):
  • [35] Correlation Between Apparent Diffusion Coefficient and the Ki-67 Proliferation Index in Grading Pediatric Glioma
    Yao, Rong
    Cheng, Ailan
    Zhang, Zhengwei
    Jin, Biao
    Yu, Hong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (02) : 322 - 328
  • [36] Correlation between minimum apparent diffusion coefficient values and the histological grade of breast invasive ductal carcinoma
    Zhao, Suhong
    Guo, Weihua
    Tan, Ru
    Chen, Peipei
    Li, Zhaohua
    Sun, Fengguo
    Shao, Guangrui
    ONCOLOGY LETTERS, 2018, 15 (05) : 8134 - 8140
  • [37] Correlation between 3T apparent diffusion coefficient values and grading of invasive breast carcinoma
    Su, M. -Y. L.
    BREAST DISEASES, 2015, 26 (02): : 137 - 139
  • [38] Correlation between Estimated Glomerular Filtration Rate (eGFR) and Apparent Diffusion Coefficient (ADC) Values of the Kidneys
    Toya, Reiko
    Naganawa, Shinji
    Kawai, Hisashi
    Ikeda, Mitsuru
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2010, 9 (02) : 59 - 64
  • [39] Correlation between 3T apparent diffusion coefficient values and grading of invasive breast carcinoma
    Cipolla, Valentina
    Santucci, Domiziana
    Guerrieri, Daniele
    Drudi, Francesco Maria
    Meggiorini, Maria Letizia
    de Felice, Carlo
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (12) : 2144 - 2150
  • [40] SPATIAL CORRELATION BETWEEN APPARENT DIFFUSION COEFFICIENT AND 18 F-FDOPA PET IN DIFFUSE GLIOMAS
    Ellingson, Benjamin
    Pope, Whitney
    Leu, Kevin
    Chen, Wei
    Czernin, Johannes
    Phelps, Michael
    Lai, Albert
    Nghiemphu, Phioanh
    Liau, Linda
    Cloughesy, Timothy
    NEURO-ONCOLOGY, 2013, 15 : 195 - 195