Daily Based Quality Assurance of Volumetric Modulated Arc Therapy for the Full Session of Treatment

被引:0
作者
Mohammad Mahfujur Rahman
Chan Hyeong Kim
Seonghoon Kim
机构
[1] Hanyang University,Department of Nuclear Engineering
[2] Hanyang University Medical Center,Department of Radiation Oncology
来源
Journal of the Korean Physical Society | 2018年 / 73卷
关键词
RapidArc; MLC; Quality assurance; Portal dosimetry; Dynalog files;
D O I
暂无
中图分类号
学科分类号
摘要
Volumetric modulated arc therapy (VMAT) with highly complex advanced delivering technique, is widely practiced in radiation therapy and requires a quality assurance for treatment plan at least once a treatment session. In this study we collected six VMAT patients with different treatment sites. The VMAT plans and their quality assurance (QA) plans were performed on a daily basis before treatment for their full period of treatment. We tried to evaluate the accuracy of their delivering through analyses of first mechanical error of multileaf collimator (MLC) movement and second dosimetric error of beam delivery. We used a MATLAB program and portal dosimetry to estimate a maximum root mean square (RMS) error from dynalog files for mechanical analysis and a gamma index from portal dosimetry for dosimetric analysis, respectively. We introduced newly in this study a representative VMAT QA to be used to perform a routine VMAT QA. The daily variation of maximum error RMSs for all treatment sites were all below maximum 0.3503 ± 0.0002 mm for treatment plans and QA plans and they all showed the gamma pass rate of more than 98%. Mean of inter difference between treatment and QA plans stayed below 0.04 mm, showing that QA deliveries agree well with treatment deliveries. The Linac used kept a good performance within the tolerances in American Association of Physicists in Medicine (AAPM) TG142 guideline for the period of research. We suggest that the representative VMAT QA can be a good surrogate for real VMAT plan and “whole time” plan QA for a patient selected randomly at least once a year be performed to confirm the long-term stability of Linac performance.
引用
收藏
页码:990 / 1000
页数:10
相关论文
共 50 条
  • [31] Statistical process control and process capability analysis for non-normal volumetric modulated arc therapy patient-specific quality assurance processes
    Xiao, Qing
    Bai, Sen
    Li, Guangjun
    Yang, Kaixuan
    Bai, Long
    Li, Zhibin
    Chen, Li
    Xian, Lixun
    Hu, Zhenyao
    Zhong, Renming
    MEDICAL PHYSICS, 2020, 47 (10) : 4694 - 4702
  • [32] Improvement of treatment plan quality with modified fixed field volumetric modulated arc therapy in cervical cancer
    Jindakan, Sirawat
    Tharavichitkul, Ekkasit
    Watcharawipha, Anirut
    Nobnop, Wannapha
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (10):
  • [33] Systematic method for a deep learning-based prediction model for gamma evaluation in patient-specific quality assurance of volumetric modulated arc therapy
    Tomori, Seiji
    Kadoya, Noriyuki
    Kajikawa, Tomohiro
    Kimura, Yuto
    Narazaki, Kakutarou
    Ochi, Takahiro
    Jingu, Keiichi
    MEDICAL PHYSICS, 2021, 48 (03) : 1003 - 1018
  • [34] Minimum requirements for commissioning and long-term quality assurance of Elekta multi-leaf collimator for volumetric modulated arc therapy
    Tatsumi D.
    Nakada R.
    Yomoda A.
    Ishii K.
    Tsutsumi S.
    Inoue M.
    Ichida T.
    Hosono M.N.
    Miki Y.
    Radiological Physics and Technology, 2013, 6 (1) : 98 - 106
  • [35] The Development of a Novel Radiation Treatment Modality-Volumetric Modulated Arc Therapy
    Song, Yulin
    Zhang, Pengpeng
    Wang, Ping
    Obcemea, Ceferino
    Mueller, Boris
    Burman, Chandra
    Mychalczak, Borys
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3401 - 3404
  • [36] Quality of treatment plans and accuracy of in vivo portal dosimetry in hybrid intensity-modulated radiation therapy and volumetric modulated arc therapy for prostate cancer
    Bedford, James L.
    Smyth, Gregory
    Hanson, Ian M.
    Tree, Alison C.
    Dearnaley, David P.
    Hansen, Vibeke N.
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (02) : 320 - 326
  • [37] On the role of the optimization algorithm of RapidArc® volumetric modulated arc therapy on plan quality and efficiency
    Vanetti, Eugenio
    Nicolini, Giorgia
    Nord, Janne
    Peltola, Jarkko
    Clivio, Alessandro
    Fogliata, Antonella
    Cozzi, Luca
    MEDICAL PHYSICS, 2011, 38 (11) : 5844 - 5856
  • [38] Single Arc Volumetric Modulated Arc Therapy of head and neck cancer
    Bertelsen, Anders
    Hansen, Christian R.
    Johansen, Jorgen
    Brink, Carsten
    RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 142 - 148
  • [39] Couch modelling for volumetric modulated arc therapy (VMAT)
    Chyou, Te-yu
    Lorenz, Friedlieb
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (02) : 471 - 480
  • [40] Performance evaluation of gated volumetric modulated arc therapy
    Swamy, S. Thirumalai
    Radha, C. Anu
    Arun, G.
    Kathirvel, M.
    Subramanian, V.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (02): : 81 - 90