Daily Based Quality Assurance of Volumetric Modulated Arc Therapy for the Full Session of Treatment

被引:0
|
作者
Mohammad Mahfujur Rahman
Chan Hyeong Kim
Seonghoon Kim
机构
[1] Hanyang University,Department of Nuclear Engineering
[2] Hanyang University Medical Center,Department of Radiation Oncology
来源
Journal of the Korean Physical Society | 2018年 / 73卷
关键词
RapidArc; MLC; Quality assurance; Portal dosimetry; Dynalog files;
D O I
暂无
中图分类号
学科分类号
摘要
Volumetric modulated arc therapy (VMAT) with highly complex advanced delivering technique, is widely practiced in radiation therapy and requires a quality assurance for treatment plan at least once a treatment session. In this study we collected six VMAT patients with different treatment sites. The VMAT plans and their quality assurance (QA) plans were performed on a daily basis before treatment for their full period of treatment. We tried to evaluate the accuracy of their delivering through analyses of first mechanical error of multileaf collimator (MLC) movement and second dosimetric error of beam delivery. We used a MATLAB program and portal dosimetry to estimate a maximum root mean square (RMS) error from dynalog files for mechanical analysis and a gamma index from portal dosimetry for dosimetric analysis, respectively. We introduced newly in this study a representative VMAT QA to be used to perform a routine VMAT QA. The daily variation of maximum error RMSs for all treatment sites were all below maximum 0.3503 ± 0.0002 mm for treatment plans and QA plans and they all showed the gamma pass rate of more than 98%. Mean of inter difference between treatment and QA plans stayed below 0.04 mm, showing that QA deliveries agree well with treatment deliveries. The Linac used kept a good performance within the tolerances in American Association of Physicists in Medicine (AAPM) TG142 guideline for the period of research. We suggest that the representative VMAT QA can be a good surrogate for real VMAT plan and “whole time” plan QA for a patient selected randomly at least once a year be performed to confirm the long-term stability of Linac performance.
引用
收藏
页码:990 / 1000
页数:10
相关论文
共 50 条
  • [1] Daily Based Quality Assurance of Volumetric Modulated Arc Therapy for the Full Session of Treatment
    Rahman, Mohammad Mahfujur
    Kim, Chan Hyeong
    Kim, Seonghoon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (07) : 990 - 1000
  • [2] The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy
    Mans, Anton
    Schuring, Danny
    Arends, Mark P.
    Vugts, Cornelia A. J. M.
    Wolthaus, Jochem W. H.
    Lotz, Heidi T.
    Admiraal, Marjan
    Louwe, Rob J. W.
    Ollers, Michel C.
    van de Kamer, Jeroen B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (19) : 7221 - 7235
  • [3] A Systematic Approach to Patient-Specific Quality Assurance for Volumetric Modulated Arc Therapy
    SONG Yu-lin
    Ceferino Obcemea
    Boris Mueller
    Borys Mychalczak
    Chinese Journal of Biomedical Engineering, 2015, 24 (02) : 58 - 65
  • [4] A novel method for routine quality assurance of volumetric-modulated arc therapy
    Wang, Qingxin
    Dai, Jianrong
    Zhang, Ke
    MEDICAL PHYSICS, 2013, 40 (10)
  • [5] Identical Quality Assurance for Volumetric Modulated Arc Therapy in Elekta and Varian Machines
    Wang, Jiazhou
    Hu, Weigang
    Peng, Jiayuan
    Lu, Saiquan
    Zhao, Jun
    Xiao, Ying
    Zhang, Zhen
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (04) : 483 - 490
  • [6] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Amoabeng, Kwame Anokye
    Marthinsen, Anne Beate Langeland
    Hasford, Francis
    Tagoe, Samuel Nii Adu
    Anaafi, Evelyn
    HEALTH AND TECHNOLOGY, 2022, 12 (04) : 779 - 786
  • [7] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Kwame Anokye Amoabeng
    Anne Beate Langeland Marthinsen
    Francis Hasford
    Samuel Nii Adu Tagoe
    Evelyn Anaafi
    Health and Technology, 2022, 12 : 779 - 786
  • [8] Quality assurance of volumetric modulated arc therapy: Evaluation and comparison of different dosimetric systems
    Masi, L.
    Casamassima, F.
    Doro, R.
    Francescon, P.
    MEDICAL PHYSICS, 2011, 38 (02) : 612 - 621
  • [9] Impact of iso-dose levels on pre-treatment quality assurance in volumetric modulated arc therapy
    Sumanta Manna
    Sanjib Gayen
    Sonal Varshney
    Radiological Physics and Technology, 2025, 18 (2) : 505 - 513
  • [10] VOLUMETRIC-MODULATED ARC THERAPY: EFFECTIVE AND EFFICIENT END-TO-END PATIENT-SPECIFIC QUALITY ASSURANCE
    O'Daniel, Jennifer
    Das, Shiva
    Wu, Q. Jackie
    Yin, Fang-Fang
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1567 - 1574