Efficiency of using the upper reservoir of the Zagorsk pumped-storage station

被引:0
|
作者
Magruk V.I. [1 ]
Rodionov V.G. [1 ]
Ordinyan N.A. [1 ]
Osin E.A. [1 ]
Nadtochii V.M. [1 ]
机构
关键词
Efficiency; Hydroelectric power plant; Loss; Pumped storage; Reservoir; Water level;
D O I
10.1007/BF02764546
中图分类号
学科分类号
摘要
Operating efficiency depends, among other things, on the useful storage and non-productive water losses from the upper reservoir. This article details analysis of these two factors for the Zagorsk pumped storage hydroelectric power station. The analysis is based on data provided by a sub-system of the plant's automatic control system. The upper reservoir of this plant is characterised by standing waves with a complex frequency spectrum with undamped character. The excess level of the crest of the upper embankment should consider these standing waves. Standard systems for measuring the upper pool level should provide for averaging the measurements. Installation of pre-turbine gates at new pumped storage plants are recommended for the elimination of non-productive water losses.
引用
收藏
页码:599 / 602
页数:3
相关论文
共 50 条
  • [31] ZOOPLANKTON COMMUNITIES OF A NEW PUMPED-STORAGE RESERVOIR
    POTTER, DU
    MEYER, JL
    WATER RESOURCES BULLETIN, 1982, 18 (04): : 635 - 642
  • [32] A NEW APPROACH FOR COMPUTING PERMEABILITY OF FAULT ZONES CASE STUDY: THE UPPER RESERVOIR OF AZAD PUMPED-STORAGE POWER STATION IN IRAN
    Anvari, A. A.
    Katibeh, H.
    Sharifzade, M.
    ARCHIVES OF MINING SCIENCES, 2010, 55 (03) : 605 - 621
  • [33] Safety of structures on a rock-free bed at the Zagorsk pumped-storage power plant
    Britvin S.O.
    Ivashchenko I.N.
    Blinov I.F.
    Magruk V.I.
    Chernenko V.N.
    Hydrotechnical Construction, 2001, 35 (9) : 453 - 457
  • [34] Rehabilitation of the dam sealing on the upper reservoir of the Hohenwarte II pumped-storage power plant
    Saenger, Franz
    Gerbothe, Dagobert
    Mueller, Marco
    WASSERWIRTSCHAFT, 2018, 108 (06) : 98 - 103
  • [35] Bacterial Diversity in the Asphalt Concrete Lining of the Upper Water Reservoir of a Pumped-Storage Scheme
    Spano, Miroslav
    Riha, Jaromir
    Spanova, Alena
    Sedo, Ondrej
    Rittich, Bohuslav
    WATER, 2020, 12 (11) : 1 - 15
  • [36] Rehabilitation of the dam sealing on the upper reservoir of the Hohenwarte II pumped-storage power plant
    Saenger, Franz
    Gerbothe, Dagobert
    Mueller, Marco
    WASSERWIRTSCHAFT, 2018, 108 : 95 - 100
  • [37] Pumped-storage Power Station Zarnowiec Poland.
    Szmurlo, Tadeusz
    Fugiel, Wladyslaw
    Przeglad Elektrotechniczny, 1984, 60 (06): : 201 - 209
  • [39] Grid effect on Stability of Pumped-Storage Hydro Station
    Mansoor, Sa'ad
    2014 PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON MODELLING, IDENTIFICATION & CONTROL (ICMIC), 2014, : 33 - 37
  • [40] Pumpspeicherwerk Limberg IILimberg II pumped-storage station
    E. Wagner
    P. Stering
    E. Binder
    K. Wimmer
    Österreichische Wasser- und Abfallwirtschaft, 2007, 59 (5-6) : 69 - 75