Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries

被引:0
作者
K. Bales
S. Dewji
E. Sanchez
机构
[1] Center for Radiation Protection Knowledge,Oak Ridge National Laboratory
[2] University of Tennessee,Department of Nuclear Engineering
[3] Knoxville,Department of Nuclear Science and Engineering
[4] Massachusetts Institute of Technology,undefined
来源
Radiation and Environmental Biophysics | 2018年 / 57卷
关键词
Anthropomorphic phantoms; Monte Carlo simulation; MCNP; Dose reconstruction;
D O I
暂无
中图分类号
学科分类号
摘要
Neutron dose coefficients for standard irradiation geometries have been reported in International Commission on Radiological Protection (ICRP) Publication 116 for the ICRP Publication 110 adult reference phantoms. In the present work, organ and effective dose coefficients have been calculated for a receptor in both upright and articulated (bent) postures representing more realistic working postures exposed to a mono-energetic neutron radiation field. This work builds upon prior work by Dewji and co-workers comparing upright and bent postures for exposure to mono-energetic photon fields. Simulations were conducted using the Oak Ridge National Laboratory’s articulated stylized adult phantom, “Phantom wIth Moving Arms and Legs” (PIMAL) software package, and the Monte Carlo N-Particle (MCNP) version 6.1.1 radiation transport code. Organ doses were compared for the upright and bent (45° and 90°) phantom postures for neutron energies ranging from 1 × 10− 9 to 20 MeV for the ICRP Publication 116 external exposure geometries—antero-posterior (AP), postero-anterior (PA), and left and right lateral (LLAT, RLAT). Using both male and female phantoms, effective dose coefficients were computed using ICRP Publication 103 methodology. The resulting coefficients for articulated phantoms were compared to those of the upright phantom. Computed organ and effective dose coefficients are discussed as a function of neutron energy, phantom posture, and source irradiation geometry. For example, it is shown here that for the AP and PA irradiation geometries, the differences in the organ coefficients between the upright and bent posture become more pronounced with increasing bending angle. In the AP geometry, the brain dose coefficients are expectedly higher in the bent postures than in the upright posture, while all other organs have lower dose coefficients, with the thyroid showing the greatest difference. Overall, the effective dose estimated for the upright phantom is more conservative than that for the articulated phantom, which may have ramifications in the estimation or reconstruction of radiation doses.
引用
收藏
页码:375 / 393
页数:18
相关论文
共 42 条
[1]  
Akkurt H(2009)Assessment of organ doses for a glovebox worker using realistic postures with PIMAL and VOXMAT Trans Am Nucl Soc 101 671-673
[2]  
Bekar K(2016)Conversion coefficients for proton beams using standing and sitting male hybrid computational phantom calculated in idealized irradiation geometries Radiat Prot Dosim 175 75-86
[3]  
Eckerman KF(2016)Radiation protection of the eye lens in medical workers—basis and impact of the ICRP recommendations Brit J Radiol 89 20151034-374
[4]  
Alves M(2016)Comparison of monoenergetic photon organ dose rate coefficients for stylized and voxel phantoms submerged in air Radiat Prot Dosim 172 367-1857
[5]  
Santos W(2015)Estimated dose rates to members of the public from external exposure to patients with 131I thyroid treatment Med Phys 42 1851-291
[6]  
Lee C(2017)Comparison of organ doses for PIMAL stylized phantoms in upright and bent positions for standard irradiation geometries Radiat Environ Biophys 56 277-45
[7]  
Bolch W(2014)Effective dose conversion coefficients for health care provider exposed to pediatric and adult victims in radiological dispersal device incident J Radiol Prot 35 37-343
[8]  
Hunt J(2017)Comparison of monoenergetic photon organ dose rate coefficients for the female stylized and voxel phantoms submerged in air Radiat Prot Dosim 175 336-5286
[9]  
Júnior AC(2014)Development of posture-specific computational phantoms using motion capture technology and application to radiation dose-reconstruction for the 1999 Tokai-Mura nuclear criticality accident Phys Med Biol 59 5277-R302
[10]  
Barnard SG(2014)An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history Phys Med Biol 59 R233-undefined