Analysis of the ear pulse oximeter waveform

被引:37
作者
Awad A.A. [1 ]
Stout R.G. [1 ]
Ghobashy M.A.M. [1 ]
Rezkanna H.A. [2 ]
Silverman D.G. [1 ]
Shelley K.H. [1 ]
机构
[1] Department of Anesthesia, Yale University School of Medicine, New Haven, CT 06516-8051
[2] Department of Anesthesia, Benha Faculty of Medicine, Zagazig University, Zagazig
关键词
Cardiac output; Ear pulse oximeter; Peripheral waveforms;
D O I
10.1007/s10877-006-9018-z
中图分类号
学科分类号
摘要
Objective: For years researchers have been attempting to understand the relationship between central hemodynamics and the resulting peripheral waveforms. This study is designed to further understanding of the relationship between ear pulse oximeter waveforms, finger pulse oximeter waveforms and cardiac output (CO). It is hoped that with appropriate analysis of the peripheral waveforms, clues can be gained to help to optimize cardiac performance. Methods. Part 1: Studying the effect of cold immersion test on plethysmographic waveforms. Part 2: Studying the correlation between ear and finger plethysmographic waveforms and (CO) during CABG surgery. The ear and finger plethysmographic waveforms were analyzed to determine amplitude, width, area, upstroke and downslope. The CO was measured using continuous PA catheter. Using multi-linear regr ession, ear plethysmographic waveforms, together with heart rate (HR), were used to determine the CO Agreement between the two methods of CO determination was assessed. Results. Part 1: On contralateral hand immersion, all finger plethysmographic waveforms were reduced, there was no significant change seen in ear plethysmographic waveforms, except an increase in ear plethysmographic width. Part 2: Phase1: Significant correlation detected between the ear plethysmographic width and other ear and finger plethysmographic waveforms. Phase 2: The ear plethysmographic width had a significant correlation with the HR and CO. The correlation of the other ear plethysmographic waveforms with CO and HR are summarized (Table 5). Multi-linear regression analysis was done and the best fit equation was found to be: CO = 8.084 - 14.248 × Ear width + 0.03 × HR + 92.322 × Ear down slope+0.027 × Ear Area Using Bland & Altman, the bias was (0.05 L) but the precision (2.46) is large to be clinically accepted. Conclusion. The ear is relatively immune to vasoconstrictive challenges which make ear plethysmographic waveforms a suitable monitor for central hemodynamic changes. The ear plethysmographic width has a good correlation with CO. © Springer Science+Business Media, Inc. 2006.
引用
收藏
页码:175 / 184
页数:9
相关论文
共 31 条
  • [1] Vincent J.L., The pulmonary artery catheter: Twenty years of use, Clin Intensive Care, 4, pp. 244-248, (1990)
  • [2] Connors Jr. A.F., Speroff T., Dawson N.V., Et al., The effectiveness of right heart catheterization in the initial care of critically ill patients: SUPPORT Investigators, JAMA, 276, pp. 889-897, (1996)
  • [3] Dalen J.E., Bone R.C., Is it time to pull the pulmonary artery catheter?, JAMA, 276, pp. 916-918, (1996)
  • [4] Kelleher J.F., Pulse oximetry, J Clin Monit, 5, pp. 37-62, (1989)
  • [5] Nijboer J.A., Dorlas J.C., Mahieu H.F., Photoelectric plethysmography-some fundamental aspects of the reflection and transmission method, Clin Phys Physiol Meas, 2, pp. 205-215, (1989)
  • [6] Challoner A.V.J., Photoelectric plethysmography for estimating cutaneous blood flow, Noninvasive Physiologic Measurements, pp. 125-151, (1979)
  • [7] Clayton D.G., Webbe R.K., Ralston A.C., Et al., A comparison of performance of twenty pulse oximeters under conditions of poor perfusion, Anaesthesia, 46, pp. 3-10, (1991)
  • [8] Bhargava M., Pothula S., Improvement of pulse oximetry signal by Emla cream, Anesth Analg, 86, (1998)
  • [9] Barker S.J., Motion resistant' pulse oximetry: A comparison of new and old models, Anesth Analg, 95, pp. 967-972, (2002)
  • [10] Redford D., Lichtenthal P., Barker SA clinical comparison of pulse oximeter sensor sites in the pediatric surgical patient: Ear, nose, lip and forehead, Anesthesiology, 101, (2004)