Probabilistic comparison and assessment of proficiency testing schemes and laboratories in the somatic cell count of raw milk

被引:0
作者
Thomas F. H. Berger
Werner Luginbühl
机构
[1] Institute for Food Sciences (IFS),Agroscope
[2] ChemStat,undefined
来源
Accreditation and Quality Assurance | 2016年 / 21卷
关键词
Reference system; Somatic cell count; Proficiency testing; Statistical approach; Quality index;
D O I
暂无
中图分类号
学科分类号
摘要
The somatic cell count (SCC) of milk is one of the main indicators of the udder health status of lactating mammals and is a hygiene criterion of raw milk used to manufacture dairy products. An increase in SCC is regarded as one of the primary indicators of inflammation of the mammary gland. Therefore, SCC is relevant in food legislation as well as in the payment of ex-farm raw milk and it has a major impact on farm management and breeding programs. Its determination is one of the most frequently performed analytical tests worldwide. Routine measurements of SCC are almost exclusively done using automated fluoro-opto-electronic counting. However, certified reference materials for SCC are lacking, and the microscopic reference method is not reliable because of serious inherent weaknesses. A reference system approach may help to largely overcome these deficiencies and help to assure equivalence in SCC worldwide. The approach is characterised as a positioning system fed by different types of information from various sources. A statistical approach for comparing proficiency tests (PTs) by assessing them using a quality index PQ and assessing participating laboratories using a quality index PL, both deriving from probabilities, is proposed. The basic assumption is that PT schemes are conducted according to recognised guidelines in order to compute performance characteristics, such as z-scores, repeatability and reproducibility standard deviations. Standard deviations are compared with the method validation data from the ISO method. Input quantities close to or smaller than the reference data of the method validation or the assigned value of the PT result in values for PQ and PL close to the maximum value. Evaluation examples of well-known PTs show the practicability of the proposed approach.
引用
收藏
页码:175 / 183
页数:8
相关论文
共 12 条
  • [1] Pyörälä S(2003)Indicators of inflammation in the diagnosis of mastitis Vet Res 34 565-578
  • [2] Pendrill LR(2005)Meeting future needs for metrological traceability—a physicist’s view Accred Qual Assur 10 133-139
  • [3] Orlandini S(2011)Reference system for somatic cell counting in milk Accred Qual Assur 16 415-420
  • [4] van den Bijgaart H(2006)The international harmonized protocol for the proficiency testing of analytical chemistry laboratories Pure Appl Chem 78 145-196
  • [5] Thompson M(1989)Robust statistics: How not to reject outliers. Part 1. Basic concepts Analyst 114 1693-1697
  • [6] Ellison SLR(2009)Regular participation in proficiency testing provides long term improvements in laboratory performance: an assessment of data over time Accred Qual Assur 14 449-454
  • [7] Wood R(1998)The frequency of rounds in a proficiency test: Does it affect the performance of participants? Analyst 123 2809-2812
  • [8] Gaunt W(2001)Information system and qualifying criteria for proficiency testing schemes Accred Qual Assur 6 199-202
  • [9] Whetton M(undefined)undefined undefined undefined undefined-undefined
  • [10] Thompson M(undefined)undefined undefined undefined undefined-undefined