Assessment of the cardiac output at rest and during exercise stress using real-time cardiovascular magnetic resonance imaging in HFpEF-patients

被引:0
|
作者
Alexander Schulz
Hannah Mittelmeier
Lukas Wagenhofer
Sören J. Backhaus
Torben Lange
Ruben Evertz
Shelby Kutty
Johannes T. Kowallick
Gerd Hasenfuß
Andreas Schuster
机构
[1] University Medical Center Göttingen,Department of Cardiology and Pneumology
[2] Georg-August University,Institute of Biomedical Imaging
[3] German Center for Cardiovascular Research (DZHK),Department of Cardiology
[4] Partner Site Göttingen,Taussig Heart Center
[5] University of Technology Graz,Institute for Diagnostic and Interventional Radiology
[6] Campus Kerckhoff of the Justus-Liebig-University Giessen,School of Biomedical Engineering and Imaging Sciences
[7] Kerckhoff-Clinic,undefined
[8] Johns Hopkins Hospital and School of Medicine,undefined
[9] University Medical Center Göttingen University Medical Center Göttingen,undefined
[10] Georg-August University,undefined
[11] King’s College London,undefined
来源
The International Journal of Cardiovascular Imaging | 2024年 / 40卷
关键词
Exercise stress CMR; HFpEF; Real-time imaging; Cardiac output;
D O I
暂无
中图分类号
学科分类号
摘要
This methodological study aimed to validate the cardiac output (CO) measured by exercise-stress real-time phase-contrast cardiovascular magnetic resonance imaging (CMR) in patients with heart failure and preserved ejection fraction (HFpEF). 68 patients with dyspnea on exertion (NYHA ≥ II) and echocardiographic signs of diastolic dysfunction underwent rest and exercise stress right heart catheterization (RHC) and CMR within 24 h. Patients were diagnosed as overt HFpEF (pulmonary capillary wedge pressure (PCWP) ≥ 15mmHg at rest), masked HFpEF (PCWP ≥ 25mmHg during exercise stress but < 15mmHg at rest) and non-cardiac dyspnea. CO was calculated using RHC as the reference standard, and in CMR by the volumetric stroke volume, conventional phase-contrast and rest and stress real-time phase-contrast imaging. At rest, the CMR based CO showed good agreement with RHC with an ICC of 0.772 for conventional phase-contrast, and 0.872 for real-time phase-contrast measurements. During exercise stress, the agreement of real-time CMR and RHC was good with an ICC of 0.805. Real-time measurements underestimated the CO at rest (Bias:0.71 L/min) and during exercise stress (Bias:1.4 L/min). Patients with overt HFpEF had a significantly lower cardiac index compared to patients with masked HFpEF and with non-cardiac dyspnea during exercise stress, but not at rest. Real-time phase-contrast CO can be assessed with good agreement with the invasive reference standard at rest and during exercise stress. While moderate underestimation of the CO needs to be considered with non-invasive testing, the CO using real-time CMR provides useful clinical information and could help to avoid unnecessary invasive procedures in HFpEF patients.
引用
收藏
页码:853 / 862
页数:9
相关论文
共 25 条
  • [21] First experience with real-time magnetic resonance imaging-based investigation of respiratory influence on cardiac function in pediatric congenital heart disease patients with chronic right ventricular volume overload
    Roewer, Lena Maria
    Radke, Karl Ludger
    Hussmann, Janina
    Malik, Halima
    Eichinger, Monika
    Voit, Dirk
    Wielpuetz, Mark Oliver
    Frahm, Jens
    Klee, Dirk
    Pillekamp, Frank
    PEDIATRIC RADIOLOGY, 2023, 53 (13) : 2608 - 2621
  • [22] First experience with real-time magnetic resonance imaging-based investigation of respiratory influence on cardiac function in pediatric congenital heart disease patients with chronic right ventricular volume overload
    Lena Maria Röwer
    Karl Ludger Radke
    Janina Hußmann
    Halima Malik
    Monika Eichinger
    Dirk Voit
    Mark Oliver Wielpütz
    Jens Frahm
    Dirk Klee
    Frank Pillekamp
    Pediatric Radiology, 2023, 53 : 2608 - 2621
  • [23] Qualitative and quantitative analysis of regional left ventricular wall dynamics using real-time magnetic resonance imaging: Comparison with conventional breath-hold gradient echo acquisition in volunteers and patients
    Plein, S
    Smith, WHT
    Ridgway, JP
    Kassner, A
    Beacock, DJ
    Bloomer, TN
    Sivananthan, MU
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (01) : 23 - 30
  • [24] Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3T
    Zhu, Xiaomei
    Schwab, Felix
    Marcus, Roy
    Hetterich, Holger
    Theisen, Daniel
    Kramer, Harald
    Notohamiprodjo, Mike
    Schlett, Christopher L.
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Bamberg, Fabian
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (05) : 849 - 855
  • [25] Free breathing 2D multi-slice real-time gradient-echo cardiovascular magnetic resonance imaging: impact on left ventricular function measurements compared with standard multi-breath hold 2D steady-state free precession imaging
    Sievers, Burkhard
    Schrader, Sebastian
    Hunold, Peter
    Barkhausen, Joerg
    Erbel, Raimund
    ACTA CARDIOLOGICA, 2011, 66 (04) : 489 - 497