Biological elimination of a high concentration of hydrogen sulfide from landfill biogas

被引:0
作者
Rania Ibrahim
Abdessamad El Hassni
Shahram Navaee-Ardeh
Hubert Cabana
机构
[1] Université de Sherbrooke,Université de Sherbrooke Water Research Group, Department of Civil and Building Engineering
[2] Benha University,Benha Faculty of Engineering
来源
Environmental Science and Pollution Research | 2022年 / 29卷
关键词
Biofiltration; H; S removal; Biotrickling filter; Gas stream; Purification system; Pilot-scale;
D O I
暂无
中图分类号
学科分类号
摘要
Hydrogen sulfide (H2S) is one of the main contaminants found in biogas, which is one of the end products of the anaerobic biodegradation of proteins and other sulfur-containing compounds in solid waste. The presence of H2S is one of the factors limiting the valorization of biogas. To valorize biogas, H2S must be removed. This study evaluated the performance of a pilot-scale biotrickling filter system on H2S removal from landfill biogas. The biotrickling filter system, which was packed with stainless-steel pall rings and inoculated with an H2S-oxidizing consortium, was designed to process 1 SCFM of biogas, which corresponds to an empty bed residence time (EBRT) of 3.9 min and was used to determine the removal efficiency of a high concentration of hydrogen sulfide from landfill biogas. The biofiltration system consisted of two biotrickling filters connected in series. Results indicate that the biofiltration system reduced H2S concentration by 94 to 98% without reducing the methane concentration in the outlet biogas. The inlet concentration of hydrogen sulfide, supplied to the two-phase bioreactor, was in the range of 900 to 1500 ppmv, and the air flow rate was 0.1 CFM. The EBRTs of the two biotrickling filters were 3.9 and 0.9 min, respectively. Approximately 50 ± 15.7 ppmv of H2S gas was detected in the outlet gas. The maximum elimination capacity of the biotrickling filter system was found to be 24 g H2S·m−3·h−1, and the removal efficiency was 94 ± 4.4%. During the biological process, the performance of the biotrickling filter was not affected when the pH of the recirculated liquid decreased to 2–3. The overall performance of the biotrickling filter system was described using a modified Michaelis–Menten equation, and the Ks and Vm values for the biosystem were 34.7 ppmv and 20 g H2S·m−3·h−1, respectively.
引用
收藏
页码:431 / 443
页数:12
相关论文
共 144 条
  • [51] Kennes C(undefined) as major biogas constituents undefined undefined undefined-undefined
  • [52] Jirka AM(undefined)undefined undefined undefined undefined-undefined
  • [53] Carter MJ(undefined)undefined undefined undefined undefined-undefined
  • [54] Kennes C(undefined)undefined undefined undefined undefined-undefined
  • [55] Rene ER(undefined)undefined undefined undefined undefined-undefined
  • [56] Veiga MC(undefined)undefined undefined undefined undefined-undefined
  • [57] Ma YL(undefined)undefined undefined undefined undefined-undefined
  • [58] Yang BL(undefined)undefined undefined undefined undefined-undefined
  • [59] Zhao JL(undefined)undefined undefined undefined undefined-undefined
  • [60] Montebello AM(undefined)undefined undefined undefined undefined-undefined