Low radiation dose protocol in cardiac CT with 100 kVp: usefulness of display preset optimization

被引:0
作者
Takeshi Nakaura
Masafumi Kidoh
Naritsugu Sakaino
Shota Nakamura
Toshimitsu Nozaki
Akari Izumi
Kazunori Harada
Yasuyuki Yamashita
机构
[1] Amakusa Medical Center,Diagnostic Radiology
[2] Amakusa Medical Center,Department of Cardiovascular Internal Medicine
[3] Amakusa Medical Center,Department of Surgery
[4] Kumamoto University,Department of Diagnostic Radiology, Graduate School of Medical
来源
The International Journal of Cardiovascular Imaging | 2013年 / 29卷
关键词
MDCT; Low kilo voltage; Image quality; Radiation dose;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the radiation dose and image quality of 100 kVp cardiac CT, and the effects of display setting optimization. We randomly assigned 100 patients undergoing cardiac CT to one of following two protocols. Fifty patients underwent our conventional protocol with 120 kVp, and the other 50 patients underwent our low radiation dose protocol with 100 kVp. We compared effective dose (ED); CT number, image noise, and contrast noise ratio (CNR) of ascending aorta at 120 and 100 kVp protocol. We also performed quantitative analysis and qualitative analysis for bitmap image of 120, 100 kVp, and display preset optimization for 100 kVp images. The estimated ED was 48 % lower with the 100 kVp protocol than the 120 kVp protocol (2.8 vs. 5.5 mSv, p < 0.01). There is no significant difference in the CNR between 100 and 120 kVp protocol (18.5 ± 3.6 vs. 18.6 ± 3.8, p = 0.84). Display preset optimization significantly improved image quality of 100 kVp cardiac CT, and there is no significant difference in qualitative analysis and quantitative analysis between 100 kVp scan with optimized display preset and 120 kVp scan (p > 0.05). The 100 kVp scanning with optimized display preset offers almost same image quality at cardiac CT of thin adults under 48 % decreased radiation dose.
引用
收藏
页码:1381 / 1389
页数:8
相关论文
共 50 条
[41]   Optimization of Scan and Reconstruction Parameters for Renal Artery CT Angiography with Iterative Reconstruction at Low kVp Compared with Filtered Back Projection at 120 kVp Acquisition [J].
Lei, Pinggui ;
Jiao, Jun ;
Wang, Xiaolin ;
Duan, Qinghong ;
Zou, Xun ;
Feng, Hui ;
Mao, Jujiang ;
Wang, Pingxian .
IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (02)
[42]   A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose [J].
Pauwels, R. ;
Silkosessak, O. ;
Jacobs, R. ;
Bogaerts, R. ;
Bosmans, H. ;
Panmekiate, S. .
DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (05)
[43]   Reducing radiation in CT urography for hematuria: Effect of using 100 kilovoltage protocol [J].
Lee, Sungwon ;
Jung, Seung Eun ;
Rha, Sung Eun ;
Byun, Jae Young .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (08) :E830-E834
[44]   Pediatric chest computed tomography at 100 kVp with tin filtration: comparison of image quality with 70-kVp imaging at comparable radiation dose [J].
Sophie Vivier ;
Valérie Deken ;
Younes Arous ;
Jean-Baptiste Faivre ;
Alain Duhamel ;
Antoine Deschildre ;
Thomas Flohr ;
Jacques Remy ;
Martine Remy-Jardin .
Pediatric Radiology, 2020, 50 :188-198
[45]   Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose [J].
Leschka, Sebastian ;
Stolzmann, Paul ;
Schmid, Florian T. ;
Scheffel, Hans ;
Stinn, Bjoern ;
Marincek, Borut ;
Alkadhi, Hatem ;
Wildermuth, Simon .
EUROPEAN RADIOLOGY, 2008, 18 (09) :1809-1817
[46]   Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose [J].
Sebastian Leschka ;
Paul Stolzmann ;
Florian T. Schmid ;
Hans Scheffel ;
Bjoern Stinn ;
Borut Marincek ;
Hatem Alkadhi ;
Simon Wildermuth .
European Radiology, 2008, 18 :1809-1817
[47]   Radiation dose and image conspicuity comparison between conventional 120 kVp and 150 kVp with spectral beam shaping for temporal bone CT [J].
Kim, Chang Rae ;
Jeon, Ji Young .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 102 :68-73
[48]   Low-dose radiation with 80-kVp computed tomography to diagnose pulmonary embolism: a feasibility study [J].
Nyman, Ulf ;
Bjorkdahl, Peter ;
Olsson, Marie-Louise ;
Gunnarsson, Mikael ;
Goldman, Bitte .
ACTA RADIOLOGICA, 2012, 53 (09) :1004-1013
[49]   Low-radiation dose scan protocol for preoperative imaging for dental implant surgery using deep learning-based reconstruction in multidetector CT [J].
Yuki Sakai ;
Erina Kitamoto ;
Kazutoshi Okamura ;
Shinya Takarabe ;
Takashi Shirasaka ;
Ryoji Mikayama ;
Masatoshi Kondo ;
Masato Tatsumi ;
Tsukasa Kojima ;
Toyoyuki Kato ;
Kazunori Yoshiura .
Oral Radiology, 2022, 38 :517-526
[50]   Low-radiation dose scan protocol for preoperative imaging for dental implant surgery using deep learning-based reconstruction in multidetector CT [J].
Sakai, Yuki ;
Kitamoto, Erina ;
Okamura, Kazutoshi ;
Takarabe, Shinya ;
Shirasaka, Takashi ;
Mikayama, Ryoji ;
Kondo, Masatoshi ;
Tatsumi, Masato ;
Kojima, Tsukasa ;
Kato, Toyoyuki ;
Yoshiura, Kazunori .
ORAL RADIOLOGY, 2022, 38 (04) :517-526