Low radiation dose protocol in cardiac CT with 100 kVp: usefulness of display preset optimization

被引:0
|
作者
Takeshi Nakaura
Masafumi Kidoh
Naritsugu Sakaino
Shota Nakamura
Toshimitsu Nozaki
Akari Izumi
Kazunori Harada
Yasuyuki Yamashita
机构
[1] Amakusa Medical Center,Diagnostic Radiology
[2] Amakusa Medical Center,Department of Cardiovascular Internal Medicine
[3] Amakusa Medical Center,Department of Surgery
[4] Kumamoto University,Department of Diagnostic Radiology, Graduate School of Medical
来源
The International Journal of Cardiovascular Imaging | 2013年 / 29卷
关键词
MDCT; Low kilo voltage; Image quality; Radiation dose;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the radiation dose and image quality of 100 kVp cardiac CT, and the effects of display setting optimization. We randomly assigned 100 patients undergoing cardiac CT to one of following two protocols. Fifty patients underwent our conventional protocol with 120 kVp, and the other 50 patients underwent our low radiation dose protocol with 100 kVp. We compared effective dose (ED); CT number, image noise, and contrast noise ratio (CNR) of ascending aorta at 120 and 100 kVp protocol. We also performed quantitative analysis and qualitative analysis for bitmap image of 120, 100 kVp, and display preset optimization for 100 kVp images. The estimated ED was 48 % lower with the 100 kVp protocol than the 120 kVp protocol (2.8 vs. 5.5 mSv, p < 0.01). There is no significant difference in the CNR between 100 and 120 kVp protocol (18.5 ± 3.6 vs. 18.6 ± 3.8, p = 0.84). Display preset optimization significantly improved image quality of 100 kVp cardiac CT, and there is no significant difference in qualitative analysis and quantitative analysis between 100 kVp scan with optimized display preset and 120 kVp scan (p > 0.05). The 100 kVp scanning with optimized display preset offers almost same image quality at cardiac CT of thin adults under 48 % decreased radiation dose.
引用
收藏
页码:1381 / 1389
页数:8
相关论文
共 50 条
  • [31] The Image Quality and Radiation Dose of 100-kVp versus 120-kVp ECG-Gated 16-Slice CT Coronary Angiography
    Park, Eun-Ah
    Lee, Whal
    Kang, Jin-Hwa
    Yin, Yong Hu
    Chung, Jin Wook
    Park, Jae Hyung
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (03) : 235 - 243
  • [32] Achieving low radiation dose and contrast agents dose in coronary CT angiography at 60-kVp ultra-low tube voltage
    He, Weiling
    Huang, Feng
    Wu, Xi
    Xie, An
    Sun, Wenjie
    Liu, Peng
    Hu, Rui
    BMC MEDICAL IMAGING, 2025, 25 (01):
  • [33] Low-tube voltage 100 kVp MDCT in screening of cocaine body packing: image quality and radiation dose compared to 120 kVp MDCT
    Aissa, Joel
    Rubbert, Christian
    Boos, Johannes
    Schleich, Christoph
    Thomas, Christoph
    Kroepil, Patric
    Antoch, Gerald
    Miese, Falk
    ABDOMINAL IMAGING, 2015, 40 (07): : 2152 - 2158
  • [34] Thermoluminescence Dosimetry in Abdominal CT for Urinary Stone Detection Effective Radiation Dose Reduction With Tin Prefiltration at 100 kVp
    Grunz, Jan-Peter
    Halt, Daniel
    Schuele, Simone
    Beer, Meinrad
    Hackenbroch, Carsten
    INVESTIGATIVE RADIOLOGY, 2023, 58 (03) : 231 - 238
  • [35] Low dose computed tomography protocol optimization and its influence in radiation dose to the patient
    de Sousa, V.
    Cardoso, G.
    Bento, B.
    Carmona, S.
    Santos, A. I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S80 - S81
  • [36] Low contrast dose protocol involving a 100 kVp tube voltage for hypervascular hepatocellular carcinoma in patients with renal dysfunction
    Takeshi Nakaura
    Yasunori Nagayama
    Masafumi Kidoh
    Shinichi Nakamura
    Tomohiro Namimoto
    Kazuo Awai
    Kazunori Harada
    Yasuyuki Yamashita
    Japanese Journal of Radiology, 2015, 33 : 566 - 576
  • [37] Diagnostic Accuracy of Pulmonary CT Angiography at Low Tube Voltage: Intraindividual Comparison of a Normal-Dose Protocol at 120 kVp and a Low-Dose Protocol at 80 kVp Using Reduced Amount of Contrast Medium in a Simulation Study
    Szucs-Farkas, Zsolt
    Schibler, Fabian
    Cullmann, Jennifer
    Torrente, Jaled Charimo
    Patak, Michael A.
    Raible, Stephan
    Hoppe, Hanno
    Wyttenbach, Rolf
    Vock, Peter
    Schindera, Sebastian T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (05) : W852 - W859
  • [38] Low contrast dose protocol involving a 100 kVp tube voltage for hypervascular hepatocellular carcinoma in patients with renal dysfunction
    Nakaura, Takeshi
    Nagayama, Yasunori
    Kidoh, Masafumi
    Nakamura, Shinichi
    Namimoto, Tomohiro
    Awai, Kazuo
    Harada, Kazunori
    Yamashita, Yasuyuki
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (09) : 566 - 576
  • [39] Low-dose, volumetric helical CT - Image quality, radiation dose, and usefulness for evaluation of bronchiectasis
    Jung, KJ
    Lee, KS
    Kim, SY
    Kim, TS
    Pyeun, YS
    Lee, JY
    INVESTIGATIVE RADIOLOGY, 2000, 35 (09) : 557 - 563
  • [40] Low dose volumetric helical CT: Image quality, radiation dose and usefulness in the evaluation of airway diseases
    Jung, KJ
    Lee, KS
    Kim, S
    Kim, T
    Pyeun, Y
    Lee, JY
    RADIOLOGY, 1999, 213P : 260 - 260