Low radiation dose protocol in cardiac CT with 100 kVp: usefulness of display preset optimization

被引:0
|
作者
Takeshi Nakaura
Masafumi Kidoh
Naritsugu Sakaino
Shota Nakamura
Toshimitsu Nozaki
Akari Izumi
Kazunori Harada
Yasuyuki Yamashita
机构
[1] Amakusa Medical Center,Diagnostic Radiology
[2] Amakusa Medical Center,Department of Cardiovascular Internal Medicine
[3] Amakusa Medical Center,Department of Surgery
[4] Kumamoto University,Department of Diagnostic Radiology, Graduate School of Medical
来源
The International Journal of Cardiovascular Imaging | 2013年 / 29卷
关键词
MDCT; Low kilo voltage; Image quality; Radiation dose;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the radiation dose and image quality of 100 kVp cardiac CT, and the effects of display setting optimization. We randomly assigned 100 patients undergoing cardiac CT to one of following two protocols. Fifty patients underwent our conventional protocol with 120 kVp, and the other 50 patients underwent our low radiation dose protocol with 100 kVp. We compared effective dose (ED); CT number, image noise, and contrast noise ratio (CNR) of ascending aorta at 120 and 100 kVp protocol. We also performed quantitative analysis and qualitative analysis for bitmap image of 120, 100 kVp, and display preset optimization for 100 kVp images. The estimated ED was 48 % lower with the 100 kVp protocol than the 120 kVp protocol (2.8 vs. 5.5 mSv, p < 0.01). There is no significant difference in the CNR between 100 and 120 kVp protocol (18.5 ± 3.6 vs. 18.6 ± 3.8, p = 0.84). Display preset optimization significantly improved image quality of 100 kVp cardiac CT, and there is no significant difference in qualitative analysis and quantitative analysis between 100 kVp scan with optimized display preset and 120 kVp scan (p > 0.05). The 100 kVp scanning with optimized display preset offers almost same image quality at cardiac CT of thin adults under 48 % decreased radiation dose.
引用
收藏
页码:1381 / 1389
页数:8
相关论文
共 50 条
  • [21] Chest CT screening in patients with overweight or obesity using spectral shaping at 150 kVp: compared with 120 kVp protocol and spectral shaping at 100 kVp protocol
    Li, Jianwen
    Mai, Zhifeng
    Zhang, Zhihong
    Cui, Jiamang
    Yang, Mingjie
    Ma, Xia
    Wang, Yan
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (05) : 451 - 457
  • [22] Chest CT screening in patients with overweight or obesity using spectral shaping at 150 kVp: compared with 120 kVp protocol and spectral shaping at 100 kVp protocol
    Jianwen Li
    Zhifeng Mai
    Zhihong Zhang
    Jiamang Cui
    Mingjie Yang
    Xia Ma
    Yan Wang
    Japanese Journal of Radiology, 2020, 38 : 451 - 457
  • [23] Radiation Dose in Cardiac CT
    Mayo, John R.
    Leipsic, Jonathon A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) : 646 - 653
  • [24] CT enterography at 100 kVp with iterative reconstruction compared to 120 kVp filtered back projection: evaluation of image quality and radiation dose in the same patients
    Johnson, Evan
    Megibow, Alec J.
    Wehrli, Natasha E.
    O'Donnell, Thomas
    Chandarana, Hersh
    ABDOMINAL IMAGING, 2014, 39 (06): : 1255 - 1260
  • [25] CT enterography at 100 kVp with iterative reconstruction compared to 120 kVp filtered back projection: evaluation of image quality and radiation dose in the same patients
    Evan Johnson
    Alec J. Megibow
    Natasha E. Wehrli
    Thomas O’Donnell
    Hersh Chandarana
    Abdominal Imaging, 2014, 39 : 1255 - 1260
  • [26] Evaluating Image Quality and Radiation Dose in Pediatric CT using 90 kVp versus 120 kVp
    Choi, Y.
    Park, Y.
    Choi, C.
    Kim, J.
    Ye, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S835 - S835
  • [27] Dose optimization in cardiac CT
    Hedgire, Sandeep
    Ghoshhajra, Brian
    Kalra, Mannudeep
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 : 97 - 103
  • [28] Low-tube voltage 100 kVp MDCT in screening of cocaine body packing: image quality and radiation dose compared to 120 kVp MDCT
    Joel Aissa
    Christian Rubbert
    Johannes Boos
    Christoph Schleich
    Christoph Thomas
    Patric Kröpil
    Gerald Antoch
    Falk Miese
    Abdominal Imaging, 2015, 40 : 2152 - 2158
  • [29] Low Kilovoltage CT of the Neck with 70 kVp: Comparison with a Standard Protocol
    Gnannt, R.
    Winklehner, A.
    Goetti, R.
    Schmidt, B.
    Kollias, S.
    Alkadhi, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1014 - 1019
  • [30] CT-angiography protocol with low dose radiation and low volume contrast medium for non-cardiac chest pain
    Cakmakci, Emin
    Ozkurt, Huseyin
    Tokgoz, Safiye
    Karabay, Esra
    Ucan, Berna
    Akdogan, Melek Pala
    Basak, Muzaffer
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2014, 4 (05) : 307 - 312