Treatment of municipal wastewater in full-scale on-site sand filter reduces BOD efficiently but does not reach requirements for nitrogen and phosphorus removal

被引:0
作者
Petteri Laaksonen
Aki Sinkkonen
Gennadi Zaitsev
Esa Mäkinen
Timo Grönroos
Martin Romantschuk
机构
[1] Clewer Ltd,Department of Environmental Sciences
[2] University of Helsinki,Institute of Environmental Sciences
[3] Tekno-Forest Ltd,undefined
[4] Turun Rakentajapalvelu,undefined
[5] Kazan Federal University,undefined
来源
Environmental Science and Pollution Research | 2017年 / 24卷
关键词
Household wastewater; Sand filter; Nitrogen removal; Phosphorus removal; BOD;
D O I
暂无
中图分类号
学科分类号
摘要
A traditional sand filter for treatment of household wastewater was constructed in the fall of 2012 at Biolinja 12, Turku, Finland. Construction work was led and monitored by an authorized wastewater treatment consultant. The filter was placed on a field bordered by open ditches from all sides in order to collect excess rain and snowmelt waters. The filter was constructed and insulated from the environment so that all outflowing water was accounted for. Untreated, mainly municipal, wastewater from Varissuo suburb was pumped from a sewer separately via three septic tanks (volume = 1 m3 each) into the filters. Normally, wastewater was distributed to ground filters automatically according to pre-programmed schedule. Initially, the daily flow was 1200 L day−1 to reflect the average organic load of a household of five persons (load: ca 237 g day−1 BOD; 73 g day−1 total N; and 10.4 g day−1 total P). Later in the test, the flow rate was decreased first to 900 and then to 600 L day−1 to better reflect the average volume produced by five persons. Volumes of inlet wastewater as well as treated water were monitored by magnetic flow meters. Samples were withdrawn from the inlet water, from the water entering the filters after the third septic tank, and from the outflowing water. After an initial adaption time, the reductions in BOD and chemical oxygen demand were constantly between 92 and 98%, showing that the biological degradation process in the filters functioned optimally and clearly comply with the national and EU standards. The reduction in total nitrogen and total phosphorus, however, reached required levels only during the first months of testing, apparently when buildup of microbial biomass was still ongoing. After this initial period of 3 months showing satisfactory reduction levels, the reduction of total nitrogen varied between 5 and 25% and total phosphorus mostly between 50 and 65%. Nitrification was efficient in the filter, but as indicated by high nitrate levels and poor nitrogen reductions, denitrification was inefficient or absent. During the winter period, the temperature in the filter dropped to near freezing, but at all time points, the flow of water was unaffected by freezing. During snowmelt and heavy rain, occasional flooding was observed. Such situations may lead to dilution rather than purification of the wastewater. In conclusion, the sand filter tested worked well for reduction of the organic load in municipal wastewater but failed to sufficiently reduce nitrogen and phosphorus levels.
引用
收藏
页码:11446 / 11458
页数:12
相关论文
共 65 条
[1]  
Beal CD(2005)Process, performance, and pollution potential: a review of septic tank-soil absorption systems Aust J Soil Res 43 781-802
[2]  
Gardner EA(2013)The effect of dosed versus gravity-fed loading methods on the performance and reliability of contour trench disposal fields used for onsite wastewater treatment J Environ Qual 42 553-561
[3]  
Menzies NW(2012)Efficiency of bark, activated charcoal, foam and sand filters in reducing pollutants from greywater Water Air and Soil Pollution 223 3657-3671
[4]  
Bridson-Pateman E(2014)Dynamics and functions of bacterial communities in bark, charcoal and sand filters treating greywater Water Res 54 21-32
[5]  
Hayward J(2014)Effects of changing hydraulic and organic loading rates on pollutant reduction in bark, charcoal and sand filters treating greywater J Environ Manag 132 338-345
[6]  
Jamieson R(2013)Comparative analysis of effluent water quality from a municipal treatment plant and two on-site wastewater treatment systems Chemosphere 92 38-44
[7]  
Boutilier L(2008)Performance and hydraulics of lateral flow sand filters for on-site wastewater treatment J Hydrol Eng 13 720-728
[8]  
Lake C(2007)Performance of a stratified sand filter in removal of chemical oxygen demand, total suspended solids and ammonia nitrogen from high-strength wastewaters J Environ Manag 83 409-415
[9]  
Dalahmeh SS(2014)Comparison of carbon footprints and eutrophication impacts of rural on-site wastewater treatment plants in Finland J Clean Prod 65 439-446
[10]  
Pell M(2016)Reduction of phosphorus, nitrogen and microorganisms in pilot scale sand filter beds containing biotite, treating primary wastewater Environ Technol 37 46-54