Management of Coronary Artery Disease and Conduction Abnormalities in Transcatheter Aortic Valve Implantation

被引:1
作者
Kostopoulou A. [1 ]
Karyofillis P. [1 ]
Livanis E. [1 ]
Karavolias G. [1 ]
Theodorakis G. [1 ]
Paraskevaides J. [2 ]
Voudris V. [1 ]
机构
[1] Cardiology Department, Onassis Cardiac Surgery Center, Syngrou av 356, Kallithea, Athens
[2] 2nd University Cardiology Department, Attikon Hospital, University of Athens, Athens
关键词
Aortic valve replacement; Atrioventricular block; Coronary artery disease; Percutaneous coronary intervention; Surgery; Transcatheter aortic valve implantation;
D O I
10.1007/s11936-015-0432-8
中图分类号
学科分类号
摘要
Transcatheter aortic valve replacement (TAVR) is an expanding, catheter-based technology that allows the implantation of a prosthetic valve without requiring open heart surgery for the treatment of severe aortic stenosis (AS). The frequency of coronary artery disease (CAD) in patients (pts) with severe AS undergoing surgical treatment ranges from 30 to 50 %. This tends to be higher in pts undergoing TAVR with a prevalence of 49–76 % and is more prevalent with older age and the fact that TAVR is commonly performed in high-risk groups with more advanced cardiovascular disease. The overall influence of CAD on TAVR procedural outcomes remains controversial, and the management of concomitant artery disease is still under discussion. There are three major issues that must be addressed: the impact of CAD, optimal timing of percutaneous coronary intervention (PCI) and TAVR, and extent of revascularization. Today, TAVR is commonly performed as a stand-alone procedure with variable degrees of concomitant CAD tolerated without intervention. One of the major potential complications with TAVR is the damage to the conduction system. The requirement of permanent pacemaker (PM) implantation ranges from 9 to 49 % of cases with a mean of ~20 %, whereas surgical aortic valve replacement (sAVR) is associated with a complete heart block that requires permanent PM in 3–12 % of cases. Reports have demonstrated an increased incidence of conduction damage in patients undergoing TAVR with the CoreValve (Medtronic Minneapolis, MN, USA) prosthesis (mean 20.8 %, range 9.3–30.0 %) compared with the Edwards SAPIEN (Edwards Lifesciences LLC; Irvine, CA, USA) prosthesis (mean 5.4 %, range 0–10.1 %). Factors predicting PM implantation include preexisting bundle branch block (BB) or conduction abnormalities. The prognostic significance of new left bundle branch block (LBBB) after TAVR is unclear. In the future, new valve designs may improve the incidence of permanent PM implantation after TAVR. © 2016, Springer Science+Business Media New York.
引用
收藏
页码:1 / 13
页数:12
相关论文
共 59 条
  • [51] Mouillet G., Lellouche N., Lim P., Et al., Patients without prolonged QRS after TAVI with CoreValve device do not experience high-degree atrio-ventricular block, Catheter Cardiovasc Interv, 81, pp. 882-887, (2013)
  • [52] Urena M., Webb J.G., Tamburino C., Munoz-Garcia A.J., Cheema A., Dager A.E., Et al., Permanent pacemaker implantation after transcatheter aortic valve implantation: impact on late clinical outcomes and left ventricular function, Circulation, 129, 11, pp. 1233-1243, (2014)
  • [53] Gensas C.S., Caixeta A., Siqueira D., Carvalho L.A., Mangione J.A., Et al., Predictors of permanent pacemaker requirement after transcatheter aortic valve implantation: Insights from a Brazilian Registry, Int J Cardiol, 175, pp. 248-252, (2014)
  • [54] Nazif T.M., Dizon J.M., Hahn R.T., Xu K., Babaliaros V., Douglas P.S., Et al., Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement : the PARTNER (placement of AoRtic TraNscathetER valves) trial and registry, J Am Coll Cardiol Intv, 8, pp. 60-69, (2015)
  • [55] Kawashima T., Sato F., Visualizing anatomical evidences on atrioventricular conduction system for TAVI, Int J Cardiol, 174, pp. 1-6, (2014)
  • [56] Jilaihawi H., Chin D., Spyt T., Jeilan M., Vasa-Nicotera M., Bence J., Et al., Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis, Eur Heart J, 31, pp. 857-864, (2010)
  • [57] van der Boon R.M., Van Mieghem N.M., Theuns D.A., Nuis R.J., Nauta S.T., Serruys P.W., Et al., Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System, Int J Cardiol, 168, pp. 1269-1273, (2013)
  • [58] Brignole M., Auricchio A., Baron-Esquivias G., Bordachar P., Boriani G., Breithardt O.A., Et al., 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA), Europace, 15, pp. 1070-1118, (2013)
  • [59] Piazza N., Nuis R.J., Tzikas A., Otten A., Onuma Y., Garcia-Garcia H., Et al., Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve implantation, EuroIntervention, 6, pp. 475-484, (2010)