Human breath analysis: methods for sample collection and reduction of localized background effects

被引:0
作者
Audrey N. Martin
George R. Farquar
A. Daniel Jones
Matthias Frank
机构
[1] Lawrence Livermore National Laboratory,
[2] Michigan State University,undefined
来源
Analytical and Bioanalytical Chemistry | 2010年 / 396卷
关键词
Bioanalytical methods; Breath analysis; GC-MS; VOC; Breath condensate;
D O I
暂无
中图分类号
学科分类号
摘要
Solid-phase microextraction (SPME) was applied, in conjunction with gas chromatography–mass spectrometry, to the analysis of volatile organic compounds (VOCs) in human breath samples without requiring exhaled breath condensate collection. A new procedure, exhaled breath vapor (EBV) collection, involving the active sampling and preconcentration of a breath sample with a SPME fiber fitted inside a modified commercial breath-collection device, the RTube™, is described. Immediately after sample collection, compounds are desorbed from the SPME fiber at 250 °C in the GC-MS injector. Experiments were performed using EBV collected at −80 °C and at room temperature, and the results compared to the traditional method of collecting exhaled breath condensate at −80 °C followed by passive SPME sampling of the collected condensate. Methods are compared in terms of portability, ease-of-use, speed of analysis, and detection limits. The need for a clean air supply for the study subjects is demonstrated using several localized sources of VOC contaminants including nail polish, lemonade, and gasoline. Various simple methods to supply clean inhaled air to a subject are presented. Chemical exposures are used to demonstrate the importance of providing cleaned air (organic vapor respirator) or an external air source (tubing stretched to a separate room). These techniques allow for facile data interpretation by minimizing background contaminants. It is demonstrated herein that this active SPME breath-sampling device provides advantages in the forms of faster sample collection and data analysis, apparatus portability and avoidance of power or cooling requirements, and performance for sample collection in a contaminated environment.
引用
收藏
页码:739 / 750
页数:11
相关论文
共 317 条
  • [1] Phillips M(1999)undefined J Chromatogr B 729 75-88
  • [2] Herrera J(2003)undefined Anal Chem 75 1604-1614
  • [3] Krishnan S(1971)undefined Proc Natl Acad Sci U S A 68 2374-76
  • [4] Zain M(2004)undefined Anal Chem 76 273A-276A
  • [5] Greenberg J(2006)undefined IEEE Circuits Devices Mag 22 22-28
  • [6] Cataneo RN(2000)undefined Am J Respir Crit Care Med 161 694-499
  • [7] Giardina M(2003)undefined Am J Respir Crit Care Med 167 395-399
  • [8] Olesik SV(2003)undefined Eur Respir J 21 177-186
  • [9] Pauling L(2003)undefined Am J Respir Crit Care Med 167 1380-1386
  • [10] Robinson AB(2006)undefined Rapid Commun Mass Spectrom 20 2747-2752