Automated oscillometric determination of the ankle-brachial index: a systematic review and meta-analysis

被引:0
|
作者
Willem J Verberk
Anastasios Kollias
George S Stergiou
机构
[1] Cardiovascular Research Institute Maastricht (CARIM),Department of Research and Development
[2] Maastricht University,Third University Department of Medicine
[3] Microlife Corporation,undefined
[4] Hypertension Center,undefined
[5] Sotiria Hospital,undefined
来源
Hypertension Research | 2012年 / 35卷
关键词
ankle-brachial index; blood pressure measurement; Doppler; oscillometric; peripheral arterial disease;
D O I
暂无
中图分类号
学科分类号
摘要
Measurement of the ankle-brachial index (ABI) using a Doppler device is widely used to identify subjects with peripheral artery disease (PAD), and those who are at high risk of cardiovascular disease. This paper presents a systematic review (Medline/PubMed, Embase and Cochrane) and meta-analysis of studies assessing the usefulness of automated oscillometric devices for ABI estimation and PAD detection compared with the conventional Doppler method. A total of 25 studies including 4186 subjects were analyzed. A random-effects model analysis showed that the average oscillometric ABI was similar to the Doppler ABI (mean difference±s.e. 0.020±0.018, P=0.3) but that the absolute differences were significant (0.048±0.009, P<0.01). The pooled correlation coefficient (r) between the oscillometric and Doppler ABI was 0.71±0.05. Simultaneous arm–leg measurements resulted in a smaller difference between the average oscillometric ABI value and the average Doppler ABI value than did sequential measurements (−0.012±0.022 vs. 0.040±0.026, respectively, P<0.01). The average sensitivity and specificity of the oscillometric ABI estimation in PAD diagnosis was 69±6% and 96±1%, respectively (with Doppler ABI taken as the reference). These data suggest that an automated ABI measurement obtained by oscillometric blood pressure monitors is a reliable and practical alternative to the conventional Doppler measurement for the detection of PAD. To increase the sensitivity of the PAD diagnosis based on an oscillometric ABI, a higher threshold of 1.0 might be preferable.
引用
收藏
页码:883 / 891
页数:8
相关论文
共 50 条
  • [1] Automated oscillometric determination of the ankle-brachial index: a systematic review and meta-analysis
    Verberk, Willem J.
    Kollias, Anastasios
    Stergiou, George S.
    HYPERTENSION RESEARCH, 2012, 35 (09) : 883 - 891
  • [2] Validity and reliability of the ankle-brachial index by oscillometric blood pressure and automated ankle-brachial index
    Chongthawonsatid, Sukanya
    Dutsadeevettakul, Somchai
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2017, 22
  • [3] The accuracy of an oscillometric ankle-brachial index in the diagnosis of lower limb peripheral arterial disease: A systematic review and meta-analysis
    Herraiz-Adillo, Angel
    Cavero-Redondo, Ivan
    Alvarez-Bueno, Celia
    Martinez-Vizcaino, Vicente
    Pozuelo-Carrascosa, Diana P.
    Notario-Pacheco, Blanca
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2017, 71 (09)
  • [4] Oscillometric measurement of the ankle-brachial index
    MacDougall, Andrea M.
    Tandon, Vikas
    Wilson, Merne P.
    Wilson, Thomas W.
    CANADIAN JOURNAL OF CARDIOLOGY, 2008, 24 (01) : 49 - 51
  • [5] Ankle-Brachial Index Measurement With an Automated Oscillometric Blood Pressure Cuff: Bringing the Ankle-Brachial Index Back to the Bedside
    Dufresne, Laurence
    Jetty, Prasad
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (03) : E89 - E89
  • [6] Diagnostic accuracy of automated oscillometric determination of the ankle-brachial index in peripheral artery disease
    Hageman, David
    van den Houten, Marijn M. L.
    Pesser, Niels
    Gommans, Lindy N. M.
    Scheltinga, Marc R. M.
    Teijink, Joep A. W.
    JOURNAL OF VASCULAR SURGERY, 2021, 73 (02) : 652 - 660
  • [7] Assessing ankle-brachial index (ABI) by using automated oscillometric devices
    Kawamura, Takao
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2008, 90 (05) : 322 - 326
  • [8] Validation of automated oscillometric versus manual measurement of the ankle-brachial index
    Richart, T.
    Kouznetsova, T.
    Wizner, B.
    Struijker-Boudier, H.
    Staessen, J.
    JOURNAL OF HYPERTENSION, 2008, 26 : S499 - S499
  • [9] Validation of automated oscillometric versus manual measurement of the ankle-brachial index
    Richart, Tom
    Kuznetsova, Tatiana
    Wizner, Barbara
    Struijker-Boudier, Harry A.
    Staessen, Jan A.
    HYPERTENSION RESEARCH, 2009, 32 (10) : 884 - 888
  • [10] Automated oscillometric measurement of the ankle-brachial index in patients with coronary artery disease
    Sinski, Maciej
    Styczynski, Grzegorz
    Szmigielski, Cezary
    HYPERTENSION RESEARCH, 2013, 36 (01) : 25 - 28