Post-Fire Exposure Behavior of Circular Concrete-filled Steel Tube Column under Axial Loading

被引:0
|
作者
Aditya Kumar Tiwary
Ashok Kumar Gupta
机构
[1] Jaypee University of Information Technology,Department of Civil Engineering
关键词
Concrete-filled steel tube (CFST) columns; Ultimate strength; Secant stiffness; Ductility index; Residual strength index; Cooling regimes;
D O I
暂无
中图分类号
学科分类号
摘要
Concrete-filled steel tube (CFST) columns are a composite member which mainly consists of steel tube infilled with concrete that are increasingly being used as load-carrying members these days. In construction industry, CFST columns are being preferred for the development of tall buildings and long-span bridges. This paper presents an experimental investigation on concrete-filled steel tube (CFST) columns which were post heated and were subjected to axial loading. The thickness of the casing steel was 4 mm and 5 mm and diameter was 100 mm, 125 mm and 150 mm and were infilled with concrete of grade M30 which were used in the present study. This study also represents the behavior of CFST columns for two cooling regimes (annealing and quenching) after exposure to elevated temperatures of 600 °C and 800 °C. The results obtained from experimental analysis were compared to each other in terms of load-deformation pattern, ultimate load capacity, residual strength index, secant stiffness and ductility index. The test results showed that as compared with water quenching, annealing is slightly better for post fire cooling of CFST columns. Also, the results obtained by the experimental investigation were compared with each other on the basis of two cooling regimes.
引用
收藏
页码:52 / 65
页数:13
相关论文
共 50 条
  • [41] Energy path of circular concrete-filled steel tube stub columns under axial compression
    Yang, Di
    Zhao, Yan-Gang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 213
  • [42] Nonlinear analysis of circular concrete-filled steel tubular short columns under axial loading
    Liang, Qing Quan
    Fragomeni, Sam
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (12) : 2186 - 2196
  • [43] Post-Fire Axial Load Resistance of Concrete-Filled, Double-Skin Tube (CFDST) Stub Columns
    Imani, Reza
    Bruneau, Michel
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2018, 55 (04): : 203 - 207
  • [44] Post-fire axial load resistance of concrete-filled, double-skin tube (CFDST) stub columns
    Imani, Reza
    Bruneau, Michel
    Engineering Journal, 2018, 55 (04): : 203 - 208
  • [45] Axial compression behavior of square concrete-filled steel tube with concrete defects
    Xu, Jiahang
    Zhou, Ting
    Chen, Zhihua
    Li, Wei
    STRUCTURES, 2025, 75
  • [46] Cyclic Loading Test for Concrete-Filled U-Shaped Steel Beam to Concrete-Filled Steel Tube Column Connections
    Xu, Xing
    Cheng, Rui
    Yang, Pu
    Liu, Ruiqi
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2020, 20 (06) : 1859 - 1870
  • [47] Cyclic Loading Test for Concrete-Filled U-Shaped Steel Beam to Concrete-Filled Steel Tube Column Connections
    Xing Xu
    Rui Cheng
    Pu Yang
    Ruiqi Liu
    International Journal of Steel Structures, 2020, 20 : 1859 - 1870
  • [48] Behavior of concrete-filled steel tubular column at large axial deformation
    Qi, Hong-Hui
    Li, Guo-Qiang
    Lou, Guo-Biao
    STRUCTURES, 2024, 70
  • [49] EXPERIMENTAL BEHAVIOR OF HIGH STRENGTH CONCRETE-FILLED SQUARE STEEL TUBE UNDER BI-AXIAL ECCENTRIC LOADING
    Li, GuoChang
    Yang, Zhijian
    Lang, Yan
    ADVANCED STEEL CONSTRUCTION, 2010, 6 (04): : 963 - 975