Numerical investigation of volute tongue design on hemodynamic characteristics and hemolysis of the centrifugal blood pump

被引:0
作者
Ibrahim Basar Aka
Caglar Ozturk
Ismail Lazoglu
机构
[1] Istanbul Bilgi University,Mechatronics Engineering Department
[2] Koç University,Manufacturing and Automation Research Center
来源
SN Applied Sciences | 2021年 / 3卷
关键词
Centrifugal blood pump; Hemolysis; Numerical simulation; Volute design; Volute tongue;
D O I
暂无
中图分类号
学科分类号
摘要
In the design of rotary blood pumps, the optimization of design parameters plays an essential role in enhancing the hydrodynamic performance and hemocompatibility. This study investigates the influence of the volute tongue angle as a volute geometric parameter on the hemodynamic characteristics of a blood pump. A numerical investigation on five different versions of volute designs is carried out by utilizing a computational fluid dynamics (CFD) software ANSYS-FLUENT. The effect of volute tongue angle is evaluated regarding the hydrodynamic performance, circumferential pressure distribution, the radial force, and the blood damage potential. A series of volute configurations are constructed with a fixed radial gap (5%), but varying tongue angles ranging from 10 to 50°. The relative hemolysis is assessed with the Eulerian based empirical power-law blood damage model. The pressure-flow rate characteristics of the volute designs at a range of rotational speeds are obtained from the experimental measurements by using the blood analog fluid. The results indicate an inverse relationship between hydraulic performance and the tongue angle; at higher tongue angles, a decrease in performance was observed. However, a higher tongue angle improves the net radial force acting on the impeller. The pump achieves the optimized performance at 20° of the tongue angle with the relatively high hydrodynamic performance and minor blood damage risk.
引用
收藏
相关论文
共 96 条
[1]  
Li H(2019)Evaluation of the hemolysis and fluid dynamics of a ventricular assist device under the pulsatile flow condition [J] J Hydrodyn 31 965-975
[2]  
Gou Z(2013)The simulation of multiphase flow field in implantable blood pump and analysis of hemolytic capability [J] J Hydrodyn 25 606-615
[3]  
Huang F(2010)Applications of CFD Technique in the Design and Flow Analysis of Implantable Axial Flow Blood Pump [J] J Hydrodyn 22 518-525
[4]  
Ruan X-D(2018)Effect of blade curvature on the hemolytic and hydraulic characteristics of a centrifugal blood pump [J] The Int J Artif Organs 41 730-737
[5]  
Qian W-W(2007)Effects of tongue position and base circle diameter on the performance of a centrifugal blood pump [J] Artif Organs 31 639-645
[6]  
Fu X(2014)Spiral casing of a volute centrifugal pump [J] J Mech Sci Technol 28 2697-2706
[7]  
Li T-Y(2015)Effects of volute curvature on performance of a low specific-speed centrifugal pump at design and off-design conditions [J] J Turbomach 137 041009-041010
[8]  
Ye L(2016)CFD investigation of the influence of volute geometrical variations on hydrodynamic characteristics of circulator pump [J] Chin J Mech Eng 29 315-324
[9]  
Hong F-W(2017)The effect of geometry on the efficiency and hemolysis of centrifugal implantable blood pumps [J] ASAIO J 63 53-59
[10]  
Liu D-C(2012)Evaluation of eulerian and lagrangian models for hemolysis estimation [J] ASAIO J 58 363-372