Effect of Device Design on the In Vitro Performance and Comparability for Capsule-Based Dry Powder Inhalers

被引:0
|
作者
Jagdeep Shur
Sau Lee
Wallace Adams
Robert Lionberger
James Tibbatts
Robert Price
机构
[1] University of Bath,Pharmaceutical Surface Science Research Group, Department of Pharmacy and Pharmacology
[2] US Food and Drug Administration,Office of Generic Drugs, Center for Drug Evaluation and Research
来源
The AAPS Journal | 2012年 / 14卷
关键词
computational fluid dynamics; device design; dry powder inhaler; comparability; performance;
D O I
暂无
中图分类号
学科分类号
摘要
This study investigated the effect of modifying the design of the Cyclohaler on its aerosolization performance and comparability to the HandiHaler at multiple flow rates. The Cyclohaler and HandiHaler were designated as model test and reference unit-dose, capsule-based dry powder inhalers (DPIs), respectively. The flow field, pressure drop, and carrier particle trajectories within the Cyclohaler and HandiHaler were modeled via computational fluid dynamics (CFD). With the goal of achieving in vitro comparability to the HandiHaler, the CFD results were used to identify key device attributes and to design two modifications of the Cyclohaler (Mod 1 and Mod 2), which matched the specific resistance of the HandiHaler but exhibited different cyclonic flow conditions in the device. Aerosolization performance of the four DPI devices was evaluated by using the reference product's capsule and formulation (Spiriva capsule) and a multistage cascade impactor. The in vitro data showed that Mod 2 provided a closer match to the HandiHaler than the Cyclohaler and Mod 1 at 20, 39, and 55 l/min. The in vitro and CFD results together suggest that matching the resistance of test and reference DPI devices is not sufficient to attain comparable aerosolization performance, and the improved in vitro comparability of Mod 2 to the HandiHaler may be related to the greater degree of similarities of the flow rate of air through the pierced capsule (Qc) and the maximum impact velocity of representative carrier particles (Vn) in the Cyclohaler-based device. This investigation illustrates the importance of enhanced product understanding, in this case through the CFD modeling and in vitro characterization of aerosolization performance, to enable identification and modification of key design features of a test DPI device for achieving comparable aerosolization performance to the reference DPI device.
引用
收藏
页码:667 / 676
页数:9
相关论文
共 50 条
  • [1] Effect of Device Design on the In Vitro Performance and Comparability for Capsule-Based Dry Powder Inhalers
    Shur, Jagdeep
    Lee, Sau
    Adams, Wallace
    Lionberger, Robert
    Tibbatts, James
    Price, Robert
    AAPS JOURNAL, 2012, 14 (04): : 667 - 676
  • [2] A Quality by Design Framework for Capsule-Based Dry Powder Inhalers
    Ding, Li
    Brunaugh, Ashlee D.
    Stegemann, Sven
    Jermain, Scott V.
    Herpin, Matthew J.
    Kalafat, Justin
    Smyth, Hugh D. C.
    PHARMACEUTICS, 2021, 13 (08)
  • [3] An Investigation into the Powder Release Behavior from Capsule-Based Dry Powder Inhalers
    Huynh, B. K.
    Chen, Y.
    Fletcher, D. F.
    Young, P.
    Zhu, B.
    Traini, D.
    AEROSOL SCIENCE AND TECHNOLOGY, 2015, 49 (10) : 902 - 911
  • [4] Effect of Device Design and Formulation on the In Vitro Comparability for Multi-Unit Dose Dry Powder Inhalers
    Shur, Jagdeep
    Saluja, Bhawana
    Lee, Sau
    Tibbatts, James
    Price, Robert
    AAPS JOURNAL, 2015, 17 (05): : 1105 - 1116
  • [5] Effect of Device Design and Formulation on the In Vitro Comparability for Multi-Unit Dose Dry Powder Inhalers
    Jagdeep Shur
    Bhawana Saluja
    Sau Lee
    James Tibbatts
    Robert Price
    The AAPS Journal, 2015, 17 : 1105 - 1116
  • [6] Effects of Device and Formulation on In Vitro Performance of Dry Powder Inhalers
    Adams, Wallace P.
    Lee, Sau L.
    Plourde, Robert
    Lionberger, Robert A.
    Bertha, Craig M.
    Doub, William H.
    Bovet, Jean-Marc
    Hickey, Anthony J.
    AAPS JOURNAL, 2012, 14 (03): : 400 - 409
  • [7] Effects of Device and Formulation on In Vitro Performance of Dry Powder Inhalers
    Wallace P. Adams
    Sau L. Lee
    Robert Plourde
    Robert A. Lionberger
    Craig M. Bertha
    William H. Doub
    Jean-Marc Bovet
    Anthony J. Hickey
    The AAPS Journal, 2012, 14 : 400 - 409
  • [8] "Pierce and inhale" design in capsule based dry powder inhalers: Effect of capsule piercing and motion on aerodynamic performance of drugs
    Martinelli, Francesco
    Balducci, Anna Giulia
    Rossi, Alessandra
    Sonvico, Fabio
    Colombo, Paolo
    Buttini, Francesca
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2015, 487 (1-2) : 197 - 204
  • [9] State of the Art in Capsule-Based Dry Powder Inhalers: Deagglomeration Techniques and the Consequences for Formulation Aerosolization
    Gross, Roman
    Berkenfeld, Kai
    Schulte, Christoph
    Ebert, Anselm
    Sule, Sunita
    Sule, Ameet
    Lamprecht, Alf
    PHARMACEUTICS, 2022, 14 (06)
  • [10] Impact of selected construction elements of capsule-based dry powder inhalers on the manner of drug delivery to the lungs
    Odziomek, Marcin
    Sosnowski, Tomasz R.
    PEDIATRIA I MEDYCYNA RODZINNA-PAEDIATRICS AND FAMILY MEDICINE, 2016, 12 (04): : 466 - 470