Radiation exposure for the surgical team in a hybrid-operating room

被引:0
作者
Konard Schuetze
A. Eickhoff
C. Dehner
M. Schultheiss
F. Gebhard
P. H. Richter
机构
[1] Ulm University,Department of Trauma
来源
Journal of Robotic Surgery | 2019年 / 13卷
关键词
Hybrid-OR; Radiation; Spine surgery; Iliosacral screw; Navigation;
D O I
暂无
中图分类号
学科分类号
摘要
Hybrid-operating rooms enable the surgeon to acquire intraoperative high-resolution 2- and 3D images and use them for navigation. The radiation dose of the operating personal and the patient remains the major concern. In 9 months, 109 pelvic and spine cases were performed using a hybrid operating room. Radiation dose of the surgeon and the assisting nurse was recorded using real-time dosimeters. Lower radiation doses for the main surgeon in navigated dorsal instrumentations of the thoracic spine were recorded. Standing between the C-arm during screw placement increased the radiation dose sixfold. Lumbar dorsal instrumentation showed a similar radiation dose compared to the previous studies in traditional operating room settings. The use of a hybrid-operating room for dorsal spine instrumentation showed no increase in radiation dose compared to traditional settings. Intraoperative navigation can help to reduce the radiation dosage for the operating personnel.
引用
收藏
页码:91 / 98
页数:7
相关论文
共 43 条
  • [1] Huda W(2008)Overview of patient dosimetry in diagnostic radiology in the USA for the past 50 years Med Phys 35 5713-5728
  • [2] Nickoloff EL(2009)Cervical spine imaging using mini–C-arm fluoroscopy: patient and surgeon exposure to direct and scatter radiation J Spinal Disord Tech 22 399-403
  • [3] Boone JM(1993)Exposure of the orthopaedic surgeon to radiation J Bone Jt Surg Am 75 326-330
  • [4] Giordano BD(1987)Radiation exposure to the surgeon during closed interlocking intramedullary nailing J Bone Jt Surg Am 69 761-766
  • [5] Sanders R(2000)Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion Spine (Phila Pa 1976) 25 2637-2645
  • [6] Levin PE(2005)Increased cancer risk among surgeons in an orthopaedic hospital Occup Med (Lond) 55 498-500
  • [7] Schoen RW(1991)ICRP Publication 60: 1990 recommendations of the International Commission on Radiological Protection Ann ICRP 2 1-3
  • [8] Browner BD(2008)Cervical spine imaging using standard C-arm fluoroscopy: patient and surgeon exposure to ionizing radiation Spine (Phila Pa 1976) 33 1970-1976
  • [9] Rampersaud YR(2005)Occupational radiation exposure to the surgeon J Am Acad Orthop Surg 13 69-76
  • [10] Mastrangelo G(2016)Fluoroscopic radiation exposure in spinal surgery: in vivo evaluation for operating room personnel Clin Spine Surg 29 E331-E335