Evaluation of artificial pancreas technology for continuous blood glucose monitoring in dogs

被引:0
作者
Akihiro Mori
Peter Lee
Takeshi Yokoyama
Hitomi Oda
Kaori Saeki
Yohei Miki
Satoshi Nozawa
Daigo Azakami
Yutaka Momota
Yuki Makino
Takako Matsubara
Motohisa Osaka
Katsumi Ishioka
Toshiro Arai
Toshinori Sako
机构
[1] Nippon Veterinary and Life Science University,School of Veterinary Nursing and Technology, Faculty of Veterinary Science
[2] Nippon Veterinary and Life Science University,School of Veterinary Medicine, Faculty of Veterinary Science
[3] Kyusyu University,Department of Dental Anesthesiology, Faculty of Dental Science
来源
Journal of Artificial Organs | 2011年 / 14卷
关键词
Artificial pancreas apparatus; Dog; Glucose ;
D O I
暂无
中图分类号
学科分类号
摘要
Artificial pancreas technology, involving “closed-loop” controls with real-time blood glucose monitoring, has been increasing in reliability as its potential for clinical use and application grows. One such device, based on this technology, is the STG-22 (Nikkiso Co., Ltd., Tokyo, Japan) artificial pancreas apparatus. In order to assess the reliability and accuracy of the device for measuring blood glucose, it is important to compare its readings to those obtained using a ‘gold standard’ method, such as the hexokinase method. Therefore, in the present study, canine blood [glucose] measurements using the STG-22 were compared to those obtained using a previously established commercial reagent, Quickauto-Neo GLU-HK. Furthermore, two different sample types (whole blood versus plasma constituent) were compared to determine which sample type results in more accurate and optimal readings with the STG-22. Given that the STG-22 was not primarily designed for canine blood samples, results for canine blood samples were not accurate. Measurements performed by the STG-22 with whole blood were significantly lower than reference [glucose] counterparts. Alternatively, an opposite trend was observed with plasma measurements that were significantly higher. A conversion format using the following formula, Hexokinase [glucose] = STG-22 [glucose] × 1.407 + 1.532, was observed with canine samples in our study.
引用
收藏
相关论文
共 50 条
  • [41] Continuous glucose monitoring in the ICU: clinical considerations and consensus
    Krinsley, James S.
    Chase, J. Geoffrey
    Gunst, Jan
    Martensson, Johan
    Schultz, Marcus J.
    Taccone, Fabio S.
    Wernerman, Jan
    Bohe, Julien
    De Block, Christophe
    Desaive, Thomas
    Kalfon, Pierre
    Preiser, Jean-Charles
    CRITICAL CARE, 2017, 21
  • [42] Overview on self-monitoring of blood glucose
    Montagnana, Martina
    Caputo, Marco
    Giavarina, Davide
    Lippi, Giuseppe
    CLINICA CHIMICA ACTA, 2009, 402 (1-2) : 7 - 13
  • [43] Diagnostic value of blood glucose monitoring in practice
    Kokot, Izabela
    Pawlik-Sobecka, Lilla
    Placzkowska, Sylwia
    Zieba, Karolina
    Malolepsza, Ewa
    FAMILY MEDICINE AND PRIMARY CARE REVIEW, 2013, 15 (02) : 119 - 120
  • [44] Targeting glucose control in preterm infants: pilot studies of continuous glucose monitoring
    Thomson, Lynn
    Elleri, Daniela
    Bond, Simon
    Howlett, James
    Dunger, David B.
    Beardsall, Kathryn
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2019, 104 (04): : F353 - F359
  • [45] Comparative Evaluation of the Accuracy of Oscillometric and Direct Methods for Arterial Blood Pressure Monitoring During Anaesthesia in Dogs
    F. Valerio
    M. Mariscoli
    L. Petrizzi
    Veterinary Research Communications, 2006, 30 : 321 - 323
  • [46] Comparative evaluation of the accuracy of oscillometric and direct methods for arterial blood pressure monitoring during anaesthesia in dogs
    Valerio, F.
    Mariscoli, M.
    Petrizzi, L.
    VETERINARY RESEARCH COMMUNICATIONS, 2006, 30 (Suppl 1) : 321 - 323
  • [47] Shortcomings in the Evaluation of Blood Glucose Forecasting
    Lee, Jung Min
    Pop-Busui, Rodica
    Lee, Joyce M.
    Fleischer, Jesper
    Wiens, Jenna
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (12) : 3424 - 3431
  • [48] Outcome Prediction in Acute Stroke Patients by Continuous Glucose Monitoring: COntinuous glucose Monitoring for acute stroke Patients receiving Latest treatment (COMPLEAT) Study
    Wada, Shinichi
    Yoshimura, Sohei
    Inoue, Manabu
    Matsuki, Takayuki
    Arihiro, Shjoji
    Koga, Masatoshi
    Makino, Hisashi
    Hosoda, Kiminori
    Ihara, Masafumi
    Toyoda, Kazunori
    STROKE, 2018, 49
  • [49] Glucose abnormalities detected by continuous glucose monitoring are common in young children with Cystic Fibrosis
    Prentice, Bernadette J.
    Ooi, Chee Y.
    Verge, Charles F.
    Hameed, Shihab
    Widger, John
    JOURNAL OF CYSTIC FIBROSIS, 2020, 19 (05) : 700 - 703
  • [50] Continuous Glucose Monitoring Enabled by Fluorescent Nanodiamond Boronic Hydrogel
    Zhang, Jian
    Zheng, Yongjun
    Lee, Jimmy
    Hoover, Alex
    King, Sarah Ann
    Chen, Lifeng
    Zhao, Jing
    Lin, Qiuning
    Yu, Cunjiang
    Zhu, Linyong
    Wu, Xiaoyang
    ADVANCED SCIENCE, 2023, 10 (07)