Evaluation of artificial pancreas technology for continuous blood glucose monitoring in dogs

被引:0
|
作者
Akihiro Mori
Peter Lee
Takeshi Yokoyama
Hitomi Oda
Kaori Saeki
Yohei Miki
Satoshi Nozawa
Daigo Azakami
Yutaka Momota
Yuki Makino
Takako Matsubara
Motohisa Osaka
Katsumi Ishioka
Toshiro Arai
Toshinori Sako
机构
[1] Nippon Veterinary and Life Science University,School of Veterinary Nursing and Technology, Faculty of Veterinary Science
[2] Nippon Veterinary and Life Science University,School of Veterinary Medicine, Faculty of Veterinary Science
[3] Kyusyu University,Department of Dental Anesthesiology, Faculty of Dental Science
来源
Journal of Artificial Organs | 2011年 / 14卷
关键词
Artificial pancreas apparatus; Dog; Glucose ;
D O I
暂无
中图分类号
学科分类号
摘要
Artificial pancreas technology, involving “closed-loop” controls with real-time blood glucose monitoring, has been increasing in reliability as its potential for clinical use and application grows. One such device, based on this technology, is the STG-22 (Nikkiso Co., Ltd., Tokyo, Japan) artificial pancreas apparatus. In order to assess the reliability and accuracy of the device for measuring blood glucose, it is important to compare its readings to those obtained using a ‘gold standard’ method, such as the hexokinase method. Therefore, in the present study, canine blood [glucose] measurements using the STG-22 were compared to those obtained using a previously established commercial reagent, Quickauto-Neo GLU-HK. Furthermore, two different sample types (whole blood versus plasma constituent) were compared to determine which sample type results in more accurate and optimal readings with the STG-22. Given that the STG-22 was not primarily designed for canine blood samples, results for canine blood samples were not accurate. Measurements performed by the STG-22 with whole blood were significantly lower than reference [glucose] counterparts. Alternatively, an opposite trend was observed with plasma measurements that were significantly higher. A conversion format using the following formula, Hexokinase [glucose] = STG-22 [glucose] × 1.407 + 1.532, was observed with canine samples in our study.
引用
收藏
相关论文
共 50 条
  • [1] Evaluation of artificial pancreas technology for continuous blood glucose monitoring in dogs
    Mori, Akihiro
    Lee, Peter
    Yokoyama, Takeshi
    Oda, Hitomi
    Saeki, Kaori
    Miki, Yohei
    Nozawa, Satoshi
    Azakami, Daigo
    Momota, Yutaka
    Makino, Yuki
    Matsubara, Takako
    Osaka, Motohisa
    Ishioka, Katsumi
    Arai, Toshiro
    Sako, Toshinori
    JOURNAL OF ARTIFICIAL ORGANS, 2011, 14 (02) : 133 - 139
  • [2] Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations
    Howard, Leigh A.
    Lidbury, Jonathan A.
    Jeffe, Nicholas
    Washburn, Shannon E.
    Patterson, Carly A.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (06) : 2628 - 2635
  • [3] Early postoperative continuous glucose monitoring in pancreas transplant recipients
    Mittal, Shruti
    Franklin, Rachel H.
    Policola, Caterina
    Sharples, Edward
    Friend, Peter J.
    Gough, Stephen C. L.
    TRANSPLANT INTERNATIONAL, 2015, 28 (05) : 604 - 609
  • [4] A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
    Ahmadi, Mohammad Mahdi
    Jullien, Graham A.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2009, 3 (03) : 169 - 180
  • [5] Evaluation of two portable meters for blood glucose measurements in dogs
    Bluwol, K.
    Duarte, R.
    Lustoza, M. D.
    Simoes, D. M. N.
    Kogika, M. M.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2007, 59 (06) : 1408 - 1411
  • [6] Home monitoring of blood glucose concentrations by owners of diabetic dogs and cats
    Sieber-Ruckstuhl, NS
    Casella, M
    Reusch, CE
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 2003, 145 (11): : 537 - 543
  • [7] Evaluation of continuous flash glucose monitoring in a pediatric ICU setting
    Kotzapanagiotou, Eirini
    Tsotridou, Eleni
    Volakli, Eleni
    Dimitriadou, Meropi
    Chochliourou, Elpis
    Kalamitsou, Serafeia
    Kotzapanagiotou, Fani
    Sdougka, Maria
    Christoforidis, Athanasios
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (04) : 843 - 852
  • [8] Evaluation of continuous flash glucose monitoring in a pediatric ICU setting
    Eirini Kotzapanagiotou
    Eleni Tsotridou
    Eleni Volakli
    Meropi Dimitriadou
    Elpis Chochliourou
    Serafeia Kalamitsou
    Fani Kotzapanagiotou
    Maria Sdougka
    Athanasios Christoforidis
    Journal of Clinical Monitoring and Computing, 2020, 34 : 843 - 852
  • [9] Continuous Glucose, Insulin and Lifestyle Data Augmentation in Artificial Pancreas Using Adaptive Generative and Discriminative Models
    Kalita, Deepjyoti
    Sharma, Hrishita
    Mirza, Khalid B.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (08) : 4963 - 4974
  • [10] Glucose Monitoring in Diabetic Dogs and Cats: Adapting New Technology for Home and Hospital Care
    Wiedmeyer, Charles E.
    DeClue, Amy E.
    CLINICS IN LABORATORY MEDICINE, 2011, 31 (01) : 41 - +