Amperometric immunoassay for the detection of Salmonella pullorum using a screen - printed carbon electrode modified with gold nanoparticle-coated reduced graphene oxide and immunomagnetic beads

被引:0
|
作者
Jianfeng Fei
Wenchao Dou
Guangying Zhao
机构
[1] Zhejiang Gongshang University,Food Safety Key Lab of Zhejiang Province, School of Food Science and Biotechnology
来源
Microchimica Acta | 2016年 / 183卷
关键词
Electrochemical sensor; Silica coating; Magnetite; Magnetic particles; Sandwich assay; Bioconjugation;
D O I
暂无
中图分类号
学科分类号
摘要
The article describes a sandwich electrochemical immunoassay for detecting the food pathogen Salmonella pullorum (S. pullorum). The assay is based on the use of immunomagnetic beads (IMB) and reduced graphene oxide coated with gold nanoparticles (rGO/AuNPs) acting as an electrochemical label. The IMB were prepared via conjugation of antibody against S. pullorum (Ab1) to silica coated magnetic beads (SiO2/Fe3O4) and were used to capture S. pullorum from the sample. The rGO/AuNP were prepared by co-reduction of chloroauric acid and graphene oxide and then linked to secondary antibody (Ab2). This conjugate served as a label in a sandwich immunoassay to produce signals. The electrochemical immunoassay was carried out by immobilizing the rGO/AuNP/Ab2/S/IMB complex on a four channel screen-printed carbon electrode (4-SPCE). The assay involves the following steps: (a) Exposure of the modified 4-SPCE to the sample; (b) Electro-oxidation of the modified 4-SPCE in 0.2 M HCl; and (c) Differential pulse voltammetry (DPV). It is found that the use of the rGO/AuNP leads to strong signal amplification. The DPV signal (at an optimal working potential of +1.25 V vs. Ag/AgCl for 120 s) is linearly related to the logarithm of the concentration of S. pullorum in the range from 102 to 106 CFU⋅mL‾1. The detection limit is as low as 89 CFU⋅mL‾1. This nanoparticle-based immunoassay excels by its low cost and ease of operation, thereby providing a promising tool in clinical analysis.
引用
收藏
页码:757 / 764
页数:7
相关论文
共 50 条
  • [21] Nanosilver and Graphene Oxide Modified Screen-Printed Carbon Electrode for Electrochemical Detection of Bisphenol A
    Wan, H.
    Xie, X.
    Liu, H.
    Mahmud, S.
    Liu, H.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (11) : 1640 - 1648
  • [22] A reduced graphene oxide-cyclodextrin-platinum nanocomposite modified screen printed electrode for the detection of cysteine
    Singh, Monali
    Jaiswal, Nandita
    Tiwari, Ida
    Foster, Christopher W.
    Banks, Craig E.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 829 : 230 - 240
  • [23] A nickel nanoparticle/nafion-graphene oxide modified screen-printed electrode for amperometric determination of chemical oxygen demand
    Baojian Zhang
    Liming Huang
    Meihua Tang
    Kenneth W. Hunter
    Yan Feng
    Qianwen Sun
    Jikui Wang
    Guosong Chen
    Microchimica Acta, 2018, 185
  • [24] A nickel nanoparticle/nafion-graphene oxide modified screen-printed electrode for amperometric determination of chemical oxygen demand
    Zhang, Baojian
    Huang, Liming
    Tang, Meihua
    Hunter, Kenneth W.
    Feng, Yan
    Sun, Qianwen
    Wang, Jikui
    Chen, Guosong
    MICROCHIMICA ACTA, 2018, 185 (08)
  • [25] Disposable Electrochemical Sensor for Food Colorants Detection by Reduced Graphene Oxide and Methionine Film Modified Screen Printed Carbon Electrode
    Akkapinyo, Chutimon
    Subannajui, Kittitat
    Poo-arporn, Yingyot
    Poo-arporn, Rungtiva P.
    MOLECULES, 2021, 26 (08):
  • [26] Electrochemical Detection of Diclofenac Using a Screen-Printed Electrode Modified with Graphene Oxide and Phenanthroline
    Maghinici, Ana-Raluca
    Bounegru, Alexandra-Virginia
    Apetrei, Constantin
    CHEMOSENSORS, 2025, 13 (02)
  • [27] Sensitive Detection of Rosmarinic Acid Using Peptide-Modified Graphene Oxide Screen-Printed Carbon Electrode
    Munteanu, Irina Georgiana
    Gradinaru, Vasile Robert
    Apetrei, Constantin
    NANOMATERIALS, 2022, 12 (19)
  • [28] Sensitive amperometric biosensors for detection of glucose and cholesterol using a platinum/reduced graphene oxide/poly(3-aminobenzoic acid) film-modified screen-printed carbon electrode
    Phetsang, Sopit
    Jakmunee, Jaroon
    Mungkornasawakul, Pitchaya
    Laocharoensuk, Rawiwan
    Ounnunkad, Kontad
    BIOELECTROCHEMISTRY, 2019, 127 : 125 - 135
  • [29] Amperometric L-Lactate Biosensor Based upon a Gold Nanoparticles/Reduced Graphene Oxide/Polyallylamine Hydrochloride Modified Screen-Printed Graphite Electrode
    Istrate, Oana-Maria
    Rotariu, Lucian
    Bala, Camelia
    CHEMOSENSORS, 2021, 9 (04)
  • [30] Voltammetric detection of carbofuran determination using screen-printed carbon electrodes modified with gold nanoparticles and graphene oxide
    Jirasirichote, Apapond
    Punrat, Eakkasit
    Suea-Ngam, Akkapol
    Chailapakul, Orawon
    Chuanuwatanakul, Suchada
    TALANTA, 2017, 175 : 331 - 337