Venous incompetence in erectile dysfunction: evaluation with color-coded duplex sonography and cavernosometry/-graphy

被引:0
|
作者
G. Fürst
V. Müller-Mattheis
M. Cohnen
C. Trautner
B. Haastert
A. Saleh
J. Malms
R. Ackermann
U. Mödder
机构
[1] Institute of Diagnostic Radiology,
[2] Heinrich Heine University,undefined
[3] P. O. Box 101007,undefined
[4] D-40001 Düsseldorf,undefined
[5] Germany,undefined
[6] Department of Urology,undefined
[7] Heinrich Heine University,undefined
[8] P. O. Box 101007,undefined
[9] D-40001 Düsseldorf,undefined
[10] Germany,undefined
[11] Institute for Social Medicine and Epidemiology,undefined
[12] Charité University Hospital,undefined
[13] D-10098 Berlin,undefined
[14] Germany,undefined
[15] Department of Biometrics and Epidemiology,undefined
[16] Diabetes Research Institute at Heinrich Heine University,undefined
[17] D-40225 Düsseldorf,undefined
[18] Germany,undefined
来源
European Radiology | 1999年 / 9卷
关键词
Key words: Penile erection; Impotence; Sonography; Doppler studies; Veno-occlusive dysfunction (venous insufficiency);
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to assess the accuracy of multi-parameter measurements with color-coded duplex sonography (CCDS) for the diagnosis of venous leakage in patients with erectile dysfunction. Sixty patients with repeated unsatisfactory reactions after intracavernous injection of vasoactive substances underwent CCDS. Following intracavernous injection of prostaglandin E1, peak systolic velocity (PSV), enddiastolic velocity (EDV), time averaged velocity (TAV), resistance index (RI), and pulsatility index (PI) were measured in the cavernous arteries over 30 min (one measurement per minute). The results were compared with independent measurements based on dynamic pharmaco-cavernosometry/cavernosography (DPCC). Dynamic pharmaco-cavernosometry/cavernosography revealed venous leakage in 33 patients. Of 48 patients with normal PSV ( > 25 cm/s), 25 had veno-occlusive dysfunction and the remainder presented normal venous function. No statistically significant differences between these groups were found in EDV, RI, and PI measurements. In contrast, differences in TAV were significant between patients with (mean 9.4 ± 4.6 cm/s) and without venous leakage (mean 5.5 ± 2.2 cm/s; p = 0.001). Analysis of relative frequencies revealed a broad overlap of EDV, TAV, RI, and PI measurements between both groups. Sensitivities and specificities determined from receiver-operating-characteristic curves were > 80 % and > 50 % for a TAV threshold of 5 cm/s, and an RI threshold of 1.0. Measurements of EDV, TAV, RI, and PI in patients with repeated unsatisfactory reactions on intracavernous prostaglandin injection are poor predictors of venous leakage and should not replace DPCC in the investigation of vasculogenic impotence.
引用
收藏
页码:35 / 41
页数:6
相关论文
共 36 条
  • [21] Dynamic infusion cavernosometry and cavernosography for classifying venous erectile dysfunction and its significance for individual treatment
    Gao, Qing-Qiang
    Chen, Jian-Huai
    Chen, Yun
    Song, Tao
    Dai, Yu-Tian
    CHINESE MEDICAL JOURNAL, 2019, 132 (04) : 405 - 410
  • [22] THE VALUE OF INCREASED END DIASTOLIC VELOCITY DURING PENILE DUPLEX SONOGRAPHY IN RELATION TO PATHOLOGICAL VENOUS LEAKAGE IN ERECTILE DYSFUNCTION
    KROPMAN, RF
    SCHIPPER, J
    VONOOSTAYEN, JA
    NIJEHOLT, AABLA
    MEINHARDT, W
    JOURNAL OF UROLOGY, 1992, 148 (02): : 314 - 317
  • [23] Factors Associated with No or Insufficient Temporal Bone Window Using Transcranial Color-coded Sonography
    Lin, Yi-Pin
    Fu, Mu-Hui
    Tan, Teng-Yeow
    JOURNAL OF MEDICAL ULTRASOUND, 2015, 23 (03) : 129 - 132
  • [24] Development of a prediction model for facilitating the clinical application of transcranial color-coded duplex ultrasonography
    Duan, Jieyu
    Wang, Pengfei
    Wang, Haoyu
    Zhao, Wei
    BMC MEDICAL IMAGING, 2024, 24 (01)
  • [25] Predictive value of patient history and correlation of nocturnal penile tumescence, colour duplex Doppler ultrasonography and dynamic cavernosometry and cavernosography in the evaluation of erectile dysfunction
    CG McMahon
    K Touma
    International Journal of Impotence Research, 1999, 11 : 47 - 51
  • [26] Predictive value of patient history and correlation of nocturnal penile tumescence, colour duplex Doppler ultrasonography and dynamic cavernosometry and cavernosography in the evaluation of erectile dysfunction
    McMahon, CG
    Touma, K
    INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 1999, 11 (01) : 47 - 51
  • [27] Variants of the hepatic artery:: Detection with color-coded sonography pre and post Levovist® injection.
    Strunk, H
    von Falkenhausen, M
    Hofer, U
    Remig, J
    König, R
    Wilhelm, K
    Textor, J
    ULTRASCHALL IN DER MEDIZIN, 1999, 20 (01): : 26 - 30
  • [28] Colour Doppler sonography of flaccid penis in evaluation of erectile dysfunction
    Sen, Jyotsna
    Godara, Rajesh
    Singh, Ramender
    Airon, Raj Kumar
    ASIAN JOURNAL OF SURGERY, 2007, 30 (02) : 122 - 125
  • [29] Effects of medetomidine and medetomidine-butorphanol on transcranial color-coded duplex ultrasonography in healthy dogs
    Duque, F. J.
    Dominguez-Roldan, J. M.
    Martinez-Taboada, F.
    Macias-Garcia, B.
    Rodriguez-Medina, P.
    Barrera-Chacon, R.
    RESEARCH IN VETERINARY SCIENCE, 2013, 95 (02) : 648 - 653
  • [30] Hemodynamic effects of transurethral alprostadil measured by color duplex ultrasonography in men with erectile dysfunction
    Tam, PY
    Keller, T
    Poppiti, R
    Gesundheit, N
    Padma-Nathan, H
    JOURNAL OF UROLOGY, 1998, 160 (04): : 1321 - 1324