Comparison of image reconstruction algorithms in myocardial perfusion scintigraphy

被引:0
作者
Jingming Bai
Jun Hashimoto
Takayuki Suzuki
Tadaki Nakahara
Atsushi Kubo
Shiro Iwanaga
Hideo Mitamura
Satoshi Ogawa
机构
[1] Keio University,Department of Radiology, School of Medicine
[2] Keio University,Department of Internal Medicine, School of Medicine
来源
Annals of Nuclear Medicine | 2001年 / 15卷
关键词
myocardial perfusion scintigraphy; image reconstruction; OSEM algorithm; Tc-99m-MIBI; Tc-99m-tetrofosmin;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to compare the clinical utility of two image reconstruction algorithms in myocardial perfusion SPECT (single-photon emission computed tomography): filtered back-projection (FBP) and ordered subset expectation maximization (OSEM). A rest/stress one-day protocol with99mTc-MIBI or tetrofosmin was performed on 102 consecutive patients who underwent coronary angiography. After SPECT data acquisition, images were reconstructed with FBP and OSEM algorithms. We assessed diagnostic performance (sensitivity, specificity and accuracy) in detecting coronary artery stenosis and evaluated regional tracer uptake with a 4-point scoring system. Although there were no significant differences in diagnostic performance between FBP and OSEM reconstruction, the OSEM method yielded higher uptake in the RCA area than the FBP method by reducing the count-loss artifact due to hepatic uptake of the tracers. In addition, regional uptake in the LCX area was significantly lower in the OSEM image than in the FBP image; this phenomenon was observed mainly in patients with coronary stenosis and/or infarction in the LCX territory. In conclusion, OSEM and FBP offered comparable diagnostic performance in stress myocardial perfusion SPECT. The OSEM method contributed to reduction of the count-loss artifact in inferior and posterior walls and to easy recognition of hypoperfusion in the LCX area.
引用
收藏
页码:79 / 83
页数:4
相关论文
共 65 条
  • [1] Lange K(1984)EM reconstruction algorithms for emission and transmission tomography J Comput Assist Tomogr 8 306-316
  • [2] Carson R(1987)Convergence of the maximum likelihood reconstruction algorithm for emission computed tomography Phys Med Biol 32 463-476
  • [3] Floyad CE(1998)Intercomparison of four reconstruction techniques for positron volume imaging with rotating planar detectors Phys Med Biol 43 823-834
  • [4] Jaszczak RJ(1998)Efficient scatter modeling for incorporation in maximum likelihood reconstruction Eur J Nucl Med 25 1658-1665
  • [5] Coleman RE(1998)Application of distance-dependent resolution compensation and post-reconstruction filtering for myocardial SPECT Phys Med Biol 43 1679-1693
  • [6] Reader AJ(1999)Attenuation correction in whole-body FDG oncological studies: the role of statistical reconstruction Eur J Nucl Med 26 591-598
  • [7] Visvikis D(1999)Maximum-likelihood reconstruction with ordered subsets in bone SPECT J Nucl Med 40 1978-1984
  • [8] Erlandsson K(1998)Comparison of ordered subsets expectation maximization and Chang’s attenuation correction method in quantitative cardiac SPECT: a phantom study Nucl Med Commun 19 1149-1157
  • [9] Ott RJ(1999)Attenuation correction in whole-body FDG oncological studies: the role of statistical reconstruction Eur J Nucl Med 26 591-598
  • [10] Flower MA(1999)Bone SPECT of the spine: a comparison of attenuation correction techniques J Nucl Med 40 604-613