3D Printed, Customized Cranial Implant for Surgical Planning

被引:2
作者
Bogu V.P. [1 ]
Ravi Kumar Y. [1 ]
Asit Kumar K. [2 ]
机构
[1] Department of Mechanical Engineering, National Institute of Technology, Warangal
[2] Department of Metallurgy and Material Science, National Institute of Technology, Warangal
关键词
3D printing; Cranial implant; FDM; Surgical planning;
D O I
10.1007/s40032-016-0292-3
中图分类号
学科分类号
摘要
The main objective of the present work is to model cranial implant and printed in FDM machine (printer model used: mojo). Actually this is peculiar case and the skull has been damaged in frontal, parietal and temporal regions and a small portion of frontal region damaged away from saggital plane, complexity is to fill this frontal region with proper curvature. The Patient CT-data (Number of slices was 381 and thickness of each slice is 0.488 mm) was processed in mimics14.1 software, mimics file was sent to 3-matic software and calculated thickness of skull at different sections where cranial implant is needed then corrected the edges of cranial implant to overcome CSF (cerebrospinal fluid) leakage and proper fitting. Finally the implant average thickness is decided as 2.5 mm and printed in FDM machine with ABS plastic. © 2016, The Institution of Engineers (India).
引用
收藏
页码:255 / 259
页数:4
相关论文
共 9 条
[1]  
Singare S., Lian Q., Ping Wang W., Rapid prototyping assisted surgery planning and custom implant design, Rapid Prototyp. J. A, 15, pp. 19-23, (2009)
[2]  
Isaza Saldarriga J.F., Velez S.C., Adolfo M.D., Heno B., Carlos Andres M.E., Torres Valencia J.M., Design and manufacturing of a custom skull implant, Am. J. Eng. Appl. Sci., 4, pp. 169-174, (2011)
[3]  
Parthasarathy J., 3D Modelling, custom implants and its future perspectives in craniofacial surgery, Ann. Maxillofac. Surg. ASME, 4, pp. 9-18, (2014)
[4]  
Wu T., Engelhardt M., Fieten L., Popovic A., Radermacher K., Anatomically constrained deformation for design of cranial implant: methodology and validation, MICCAI, 4190, pp. 9-16, (2006)
[5]  
Lynnerup N., Cranial thickness in relation to age, sex and general body build in a Danish forensic sample, Forensic Sci. Int., 117, pp. 45-51, (2001)
[6]  
Van der Meer W.J., Bos R.R.M., Vissink A., Visser A., Digital planning of cranial implants (short communication), Br. J. Oral Maxillofac. Surg., 51, pp. 450-452, (2012)
[7]  
Swetha P., Anburajan M., Finite element analysis of the skull implant using Ansys software, ICECT, 3, pp. 420-425, (2011)
[8]  
Mimics 14.1 Help Manual, Materialise Company
[9]  
3-Matic 9 Help Manual, Materialise Company