Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies

被引:0
作者
Nai-Feng Tian
Qi-Shan Huang
Ping Zhou
Yang Zhou
Rui-Kai Wu
Yi Lou
Hua-Zi Xu
机构
[1] Second Affiliated Hospital of Wenzhou Medical College,Zhejiang Spine Research Center, Department of Orthopaedic Surgery
来源
European Spine Journal | 2011年 / 20卷
关键词
Navigated spine surgery; Pedicle screw; Computer tomography; Fluoroscopy; Accuracy;
D O I
暂无
中图分类号
学科分类号
摘要
Studies revealed that navigation systems that provided intraoperative assistance might improve pedicle screw insertion accuracy, and also implied that different systems provided different pedicle screw insertion accuracy. A systematic review and meta-analysis was conducted to focus on the pedicle screw insertion accuracy with or without the assistance of image-guided system, and the variance among the different navigation systems. Comparative studies were searched on pedicle screw insertion accuracy between conventional and navigated method, and among different navigation systems. A total of 43 papers, including 28 clinical, 14 cadaveric and 1 model studies, were included in the current study. For clinical articles, there were 3 randomized clinical trials, 4 prospective comparative studies and 21 retrospective comparative studies. The incidence of pedicle violation among computer tomography-based navigation method group was statistically significantly less than that observed among the conventional group (OR 95% CI, in vivo: 0.32–0.60; in vitro: 0.24–0.75 P < 0.01). Two-dimensional fluoroscopy-based navigation system (OR 95% CI, in vivo: 0.27–0.48; in vitro: 0.43–0.88 P < 0.01) and three-dimension fluoroscopy-based navigation system (OR 95% CI, in vivo: 0.09–0.38; in vitro: 0.09–0.36 P < 0.01) also obtained significant reduced screw deviation rate over traditional methods. Between navigated approaches, statistically insignificant individual and pooled RR values were observed for all in vivo subgroups. Pooled estimate of in vitro studies show that computer tomography-based and three-dimension fluoroscopy-based navigation system provided more accurate pedicle screw insertion over two-dimension fluoroscopy-based navigation system. Our review showed that navigation provided a higher accuracy in the placement of pedicle screws compared with conventional methods. The superiority of navigation systems was obvious when they were applied to abnormal spinal structure. Although no strong in vivo evidence has detected significantly different pedicle screw placement accuracy among the three major navigation systems, meta-analysis revealed the variance in pedicle screw insertion accuracy with different navigation methods.
引用
收藏
页码:846 / 859
页数:13
相关论文
共 174 条
  • [31] Fu TS(2005)Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique Chin J Surg (Chin) 43 1328-1330
  • [32] Wong CB(2005)Application of orthopaedic guidance for pedicle screw fixation of spine Orthop J Chin (Chin) 13 75-76
  • [33] Tsai TT(2004)Preliminary application of spinal navigation with the intra-operative 3D-imaging modality in pedicle screw fixation Orthop J Chin (Chin) 12 1895-1897
  • [34] Lee GY(2007)Clinical applications of computer assisted navigation technique in scoliosis surgery Orthop J Chin (Chin) 15 1773-1776
  • [35] Massicotte EM(2008)Pedicle screw placement under the guidance of computer-assisted navigation system Chin J Min Inv Surg (Chin) 8 544-546
  • [36] Rampersaud YR(2009)Computer-assisted navigation technique in the spinal pedicle screw internal fixation J Clin Rehabil Tissue Eng Res (Chin) 13 3365-3369
  • [37] Lekovic GP(2003)Experience of pedicle screw fixation in the cervical spine using navigation system J Spinal Surg (Chin) 1 15-18
  • [38] Potts EA(2002)Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models Spine 27 2503-2508
  • [39] Karahalios DG(2000)Computer-assisted fluoroscopic targeting system for pedicle screw insertion Neurosurgery 47 872-878
  • [40] Gruetzner PA(2003)Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study Spine 28 402-413