Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies

被引:0
作者
Nai-Feng Tian
Qi-Shan Huang
Ping Zhou
Yang Zhou
Rui-Kai Wu
Yi Lou
Hua-Zi Xu
机构
[1] Second Affiliated Hospital of Wenzhou Medical College,Zhejiang Spine Research Center, Department of Orthopaedic Surgery
来源
European Spine Journal | 2011年 / 20卷
关键词
Navigated spine surgery; Pedicle screw; Computer tomography; Fluoroscopy; Accuracy;
D O I
暂无
中图分类号
学科分类号
摘要
Studies revealed that navigation systems that provided intraoperative assistance might improve pedicle screw insertion accuracy, and also implied that different systems provided different pedicle screw insertion accuracy. A systematic review and meta-analysis was conducted to focus on the pedicle screw insertion accuracy with or without the assistance of image-guided system, and the variance among the different navigation systems. Comparative studies were searched on pedicle screw insertion accuracy between conventional and navigated method, and among different navigation systems. A total of 43 papers, including 28 clinical, 14 cadaveric and 1 model studies, were included in the current study. For clinical articles, there were 3 randomized clinical trials, 4 prospective comparative studies and 21 retrospective comparative studies. The incidence of pedicle violation among computer tomography-based navigation method group was statistically significantly less than that observed among the conventional group (OR 95% CI, in vivo: 0.32–0.60; in vitro: 0.24–0.75 P < 0.01). Two-dimensional fluoroscopy-based navigation system (OR 95% CI, in vivo: 0.27–0.48; in vitro: 0.43–0.88 P < 0.01) and three-dimension fluoroscopy-based navigation system (OR 95% CI, in vivo: 0.09–0.38; in vitro: 0.09–0.36 P < 0.01) also obtained significant reduced screw deviation rate over traditional methods. Between navigated approaches, statistically insignificant individual and pooled RR values were observed for all in vivo subgroups. Pooled estimate of in vitro studies show that computer tomography-based and three-dimension fluoroscopy-based navigation system provided more accurate pedicle screw insertion over two-dimension fluoroscopy-based navigation system. Our review showed that navigation provided a higher accuracy in the placement of pedicle screws compared with conventional methods. The superiority of navigation systems was obvious when they were applied to abnormal spinal structure. Although no strong in vivo evidence has detected significantly different pedicle screw placement accuracy among the three major navigation systems, meta-analysis revealed the variance in pedicle screw insertion accuracy with different navigation methods.
引用
收藏
页码:846 / 859
页数:13
相关论文
共 174 条
  • [21] Kosmopoulos V(2007)Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique Spine 32 1543-1550
  • [22] Schizas C(1997)Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients Spine 22 1254-1258
  • [23] Tian NF(2000)Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients Eur Spine J 9 235-240
  • [24] Xu HZ(1998)Pedicle screw placement using image guided techniques Clin Orthop Relat Res 354 39-48
  • [25] Nakanishi K(2005)Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws Spine 30 2280-2287
  • [26] Tanaka M(2008)Segmental pedicle screwing for idiopathic scoliosis using computer-assisted surgery J Spinal Disord Tech 21 181-186
  • [27] Misawa H(2001)Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study Unfallchirurg 104 1076-1081
  • [28] Arand M(2004)Accuracy of CT-based navigation of pedicle screws in the thoracic spine compared with conventional technique Unfallchirurg 107 104-112
  • [29] Schempf M(2005)Prospective screw misplacement analysis after conventional and navigated pedicle screw implantation Biomed Tech (Berl) 50 287-292
  • [30] Fleiter T(2009)Comparison study between C-arm X-ray and 3D CT in guiding thoracolumbar pedicle screw fixation Shandong Med J (Chin) 49 5-7