Simultaneous quantification of carotenoids, retinol, and tocopherols in forages, bovine plasma, and milk: validation of a novel UPLC method

被引:0
作者
B. Chauveau-Duriot
M. Doreau
P. Nozière
B. Graulet
机构
[1] UR1213 Research Unit on Herbivores,INRA
来源
Analytical and Bioanalytical Chemistry | 2010年 / 397卷
关键词
Carotenoids; Tocopherol; Retinol; Liquid chromatography; Milk; Feed; Bioanalytical methods; Biological samples; Foods/Beverages; HPLC; UV/VIS;
D O I
暂无
中图分类号
学科分类号
摘要
Simultaneous quantification of various liposoluble micronutrients is not a new area of interest since these compounds participate in the nutritional quality of feeds that is largely explored in human, and also in animal diet. However, the development of related methods is still under concern, especially when the carotenoid composition is complex such as in forages given to ruminants or in lipid-rich matrices like milk. In this paper, an original method for simultaneous extraction and quantification of all carotenoids, vitamins E, and A in milk was proposed. Moreover, a new UPLC method allowing simultaneous determination of carotenoids and vitamins A and E in forage, plasma and milk, and separation of 23 peaks of carotenoids in forages was described. This UPLC method using a HSS T3 column and a gradient solvent system was compared to a previously published reverse-phase HPLC using two C18 columns in series and an isocratic solvent system. The UPLC method gave similar concentrations of carotenoids and vitamins A and E than the HPLC method. Moreover, UPLC allowed a better resolution for xanthophylls, especially lutein and zeaxanthin, for the three isomers of β-carotene (all-E-, 9Z- and 13Z-) and for vitamins A, an equal or better sensitivity according to gradient, and a better reproducibility of peak areas and retention times, but did not reduce the time required for analysis.
引用
收藏
页码:777 / 790
页数:13
相关论文
共 132 条
[1]  
Krinsky NI(2005)Carotenoid actions and their relation to health and disease Mol Aspects Med 26 459-516
[2]  
Johnson EJ(2007)Tocopherol and carotenoid levels in baled silage and haylage in relation to horse requirements Anim Feed Sci Technol 137 182-197
[3]  
Muller CE(2005)Simultaneous quantification of α-tocopherol and four major carotenoids in botanical materials by normal phase liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry J Chromatogr A 1094 83-90
[4]  
Moller J(1985)An isocratic high-performance liquid chromatography method for the simultaneous analysis of plasma retinol, α-tocopherol, and various carotenoids Anal Biochem 145 21-26
[5]  
Krogh Jensen S(1986)Retinol, α-tocopherol, lycopene, and α- and β-carotene simultaneously determined in plasma by isocratic liquid chromatography Clin Chem 32 874-876
[6]  
Udén P(2008)Simultaneous measurement of retinol, α-tocopherol, and six carotenoids in human plasma by using an isocratic reverse-phse HPLC method J Chromatogr B 867 226-232
[7]  
Hao Z(2007)Variations in carotenoids, vitamins A and E, and color in cow’s plasma and milk during late pregnancy and the first three months of lactation J Dairy Sci 90 2335-2346
[8]  
Parker B(2001)Simple method for clinical determination of 13 carotenoids in human plasma using an isocratic high-performance liquid chromatographic method J Chromatogr B 751 297-303
[9]  
Knapp M(2000)Chromatographic determination of carotenoids in foods J Chromatogr A 881 543-555
[10]  
Yu L(1997)Evaluation and validation of an LC method for the analysis of carotenoids in vegetables and fruits Food Chem 59 599-603