Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support

被引:0
作者
Kei Iizuka
Tomohiro Nishinaka
Yuki Ichihara
Takuma Miyamoto
Kenji Yamazaki
机构
[1] Tokyo Women’s Medical University,Department of Cardiovascular Surgery
来源
Journal of Artificial Organs | 2018年 / 21卷
关键词
Aortic valve regurgitation; Left ventricular assist device; Heart failure; Continuous-flow;
D O I
暂无
中图分类号
学科分类号
摘要
Aortic valve regurgitation (AR) is a critical complication during circulatory support with a left ventricular assist device (LVAD). The time-course of AR and related factors, including outflow graft anastomosis site design, were investigated. Twenty-three patients who had continuous-flow LVAD implantation and were supported for more than 6 months were investigated. AR grade (none, 0; trivial, 0.5; mild, 1; mild-moderate, 1.5; moderate, 2; moderate-severe, 2.5; severe, 3) and aortic valve opening were evaluated with echocardiography. Computed tomography was performed to all the patients postoperatively. The angle of the outflow graft to the aorta (O-A angle, parallel 0; tangent 90°, 0–180°), aortic diameter at the anastomosis site, sino-tubular junction (STJ) diameter, distance between the STJ and the anastomosis site, and distance between the anastomosis site and the brachiocephalic artery were measured. The patients’ age was 38 ± 11 years. Support duration was 686 ± 354 days. Mean AR grade after continuous-flow LVAD implantation was increased to around mild and was maintained thereafter. No patient needed any intervention to the aortic valve. The aortic valves of 82.6% of patients were closed continuously. The O-A angle (83 ± 14) was positively correlated with maximum AR grade (p = 0.0095). The O-A angle was significantly smaller in patients with maximum AR grade of 1 or less (77 ± 9°) than in those with 1.5 or greater (94 ± 15°, p = 0.021). The other CT measurements had no correlation with AR grade. In conclusion, the O-A angle was correlated with AR grade progression. The O-A angle appears to be one of the important factors related to AR under continuous-flow LVAD support.
引用
收藏
页码:150 / 155
页数:5
相关论文
共 50 条
  • [41] A case report: transfemoral transcatheter aortic valve replacement with a dedicated valve system for severe aortic regurgitation in a patient with a left ventricular assist device
    Goncharov, Arseniy
    Fox, Henrik
    Bleiziffer, Sabine
    Rudolph, Tanja K.
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2023, 7 (06)
  • [42] Surgical correction of aortic valve insufficiency after left ventricular assist device implantation
    Atkins, B. Zane
    Hashmi, Zubair A.
    Ganapathi, Asvin M.
    Harrison, J. Kevin
    Hughes, G. Chad
    Rogers, Joseph G.
    Milano, Carmelo A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (05) : 1247 - 1252
  • [43] Aortic Valve Thrombus in a Patient With an Extracorporeal Left Ventricular Assist Device: The Dilemma of Management
    Barrick, Brian P.
    Smeltz, Alan
    Ganesh, Arun
    Arora, Harendra
    Kumar, Priya A.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (01) : 196 - 199
  • [44] Single Arterial Access for VA-ECMO-Assisted Stenting of a Left Ventricular Assist Device Outflow Graft Obstruction in the Setting of an Oversewn Aortic Valve
    Kapur, Navin K.
    Kiernan, Michael S.
    Ruiz, Nicolas
    Chweich, Haval
    CIRCULATION-HEART FAILURE, 2024, 17 (10) : e011743
  • [45] A computational fluid dynamics comparison between different outflow graft anastomosis locations of Left Ventricular Assist Device (LVAD) in a patient-specific aortic model
    Caruso, Maria Vittoria
    Gramigna, Vera
    Rossi, Michele
    Serraino, Giuseppe Filiberto
    Renzulli, Attilio
    Fragomeni, Gionata
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2015, 31 (02) : 1 - 12
  • [46] Outflow graft thrombectomy during HeartMate II left ventricular assist device exchange
    Berg, Kent B.
    Klodell, Charles T.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 19 (04) : 714 - 715
  • [47] Treatment of outflow graft stenosis in left ventricular assist device patients: Endovascular approach
    Karahan, Mehmet
    Tola, Muharrem
    Ozdemir, Mustafa
    Sert, Dogan Emre
    Kocabeyoglu, Sinan Sabit
    Kervan, Umit
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 28 (04): : 688 - 690
  • [48] Left ventricular assist device outflow graft obstruction development in the original bend relief
    Kawabori, Masashi
    Nordan, Taylor
    Arkun, Knarik
    Couper, Gregory S.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (06) : 1313 - 1313
  • [49] Influence of the Outflow Graft Angular Position on the Outcomes in Patients With a Left Ventricular Assist Device
    Zijderhand, Casper F.
    Peek, Jette J.
    Sjatskig, Jelena
    Manintveld, Olivier C.
    Bekkers, Jos A.
    Bogers, Ad J. J. C.
    Caliskan, Kadir
    ASAIO JOURNAL, 2024, 70 (10) : 861 - 867
  • [50] Percutaneous endovascular stenting to treat left ventricular assist device outflow graft stenosis
    Litvak, Aaron
    Desai, Kshitij
    Narins, Craig
    Mix, Doran
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2024, 10 (02):