Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support

被引:0
作者
Kei Iizuka
Tomohiro Nishinaka
Yuki Ichihara
Takuma Miyamoto
Kenji Yamazaki
机构
[1] Tokyo Women’s Medical University,Department of Cardiovascular Surgery
来源
Journal of Artificial Organs | 2018年 / 21卷
关键词
Aortic valve regurgitation; Left ventricular assist device; Heart failure; Continuous-flow;
D O I
暂无
中图分类号
学科分类号
摘要
Aortic valve regurgitation (AR) is a critical complication during circulatory support with a left ventricular assist device (LVAD). The time-course of AR and related factors, including outflow graft anastomosis site design, were investigated. Twenty-three patients who had continuous-flow LVAD implantation and were supported for more than 6 months were investigated. AR grade (none, 0; trivial, 0.5; mild, 1; mild-moderate, 1.5; moderate, 2; moderate-severe, 2.5; severe, 3) and aortic valve opening were evaluated with echocardiography. Computed tomography was performed to all the patients postoperatively. The angle of the outflow graft to the aorta (O-A angle, parallel 0; tangent 90°, 0–180°), aortic diameter at the anastomosis site, sino-tubular junction (STJ) diameter, distance between the STJ and the anastomosis site, and distance between the anastomosis site and the brachiocephalic artery were measured. The patients’ age was 38 ± 11 years. Support duration was 686 ± 354 days. Mean AR grade after continuous-flow LVAD implantation was increased to around mild and was maintained thereafter. No patient needed any intervention to the aortic valve. The aortic valves of 82.6% of patients were closed continuously. The O-A angle (83 ± 14) was positively correlated with maximum AR grade (p = 0.0095). The O-A angle was significantly smaller in patients with maximum AR grade of 1 or less (77 ± 9°) than in those with 1.5 or greater (94 ± 15°, p = 0.021). The other CT measurements had no correlation with AR grade. In conclusion, the O-A angle was correlated with AR grade progression. The O-A angle appears to be one of the important factors related to AR under continuous-flow LVAD support.
引用
收藏
页码:150 / 155
页数:5
相关论文
共 50 条
  • [31] Late outflow graft stenosis of left ventricular assist device and endovascular treatment
    Karaca, Sedat
    Erdinli, Dilek
    Kahraman, Umit
    Cinar, Celal
    Engin, Cagatay
    Yagdi, Tahir
    Ozbaran, Mustafa
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (02) : 154 - 158
  • [32] Residual mitral regurgitation in patients with left ventricular assist device support - An INTERMACS analysis
    Jain, Rashmi
    Truby, Lauren K.
    Topkara, Veli K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (11) : 1638 - 1645
  • [33] Combined Open Repair of an Abdominal Aortic Aneurysm and Relief of a Left Ventricular Assist Device Outflow Graft Obstruction
    Carroll, David
    Cios, Theodore J.
    Coleman, Scott
    Han, David C.
    Soleimani, Behzad
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (12) : 4420 - 4426
  • [34] Management of Aortic Insufficiency Using Transcatheter Aortic Valve Replacement in Patients with Left Ventricular Assist Device Support
    Kar, Biswajit
    Prathipati, Priyanka
    Jumean, Marwan
    Nathan, Sriram S.
    Gregoric, Igor D.
    ASAIO JOURNAL, 2020, 66 (06) : E82 - E86
  • [35] The Impact of Left Ventricular Assist Device Outflow Graft Positioning on Aortic Hemodynamics: Improving Flow Dynamics to Mitigate Aortic Insufficiency
    Gu, Zhuohan
    Ong, Chi Wei
    Mi, Yongzhen
    Seetharaman, Ashwin
    Ling, Ryan Ruiyang
    Ramanathan, Kollengode
    Leo, Hwa Liang
    BIOMIMETICS, 2023, 8 (06)
  • [36] Computed Tomography and Fluoroscopic Angiography in Management of Left Ventricular Assist Device Outflow Graft Obstruction
    Wamala, Isaac
    Kneissler, Simon
    Kaufmann, Friedrich
    Eulert-Grehn, Jaime-Juergen
    Potapov, Evgenij
    Dreysse, Stephan
    Starck, Christoph
    Falk, Volkmar
    Solowjowa, Natalia
    JACC-CARDIOVASCULAR IMAGING, 2020, 13 (09) : 2036 - 2042
  • [37] Left Ventricular Assist Device Support-Induced Alteration of Mechanical Stress on Aortic Valve and Aortic Wall
    Kainuma, Atsushi
    Itatani, Keiichi
    Hayashi, Hideyuki
    Kaku, Yuji
    Wu, Isaac Y.
    Colombo, Paolo C.
    Ferrari, Giovanni
    Kurlansky, Paul
    Yuzefpolskaya, Melana
    Takeda, Koji
    Naka, Yoshifumi
    Akiyama, Koichi
    Takayama, Hiroo
    ASAIO JOURNAL, 2022, 68 (04) : 516 - 523
  • [38] Left Ventricular Assist Device Outflow Graft Pseudoaneurysm Treated with Covered Balloon Expandable Stent
    Pya, Yuriy
    Mussayev, Abdurashid
    Alimbayev, Serik
    Medressova, Assel
    Bekbossynov, Serik
    Andossova, Saltanat
    Khissamutdinov, Nail
    Jetybayeva, Saltanat
    La Fleur, Philip
    ASAIO JOURNAL, 2020, 66 (05) : E74 - E76
  • [39] Reciprocal interferences of the left ventricular assist device and the aortic valve competence
    Vriz, Olga
    Mushtaq, Ali
    Shaik, Abdullah
    El-Shaer, Ahmed
    Feras, Khalid
    Eltayeb, Abdalla
    Alsergnai, Hani
    Kholaif, Naji
    Al Hussein, Mosaad
    Albert-Brotons, Dimpna
    Simon, Andre Rudiger
    Tsai, Felix Wang
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 9
  • [40] Concomitant Transcatheter Aortic Valve and Left Ventricular Assist Device Implantation
    Baum, Christina
    Seiffert, Moritz
    Treede, Hendrik
    Reichenspurner, Hermann
    Deuse, Tobias
    ASAIO JOURNAL, 2013, 59 (01) : 90 - 92