Does a replacement or revision of an inflatable penile prosthesis lead to decreased patient satisfaction?

被引:0
作者
A A Caire
A Boonjindasup
W J G Hellstrom
机构
[1] Tulane University School of Medicine,Department of Urology
来源
International Journal of Impotence Research | 2011年 / 23卷
关键词
ED; inflatable penile prosthesis; sexual satisfaction;
D O I
暂无
中图分类号
学科分类号
摘要
To analyze the reason for replacement, revision and overall satisfaction of a cohort who underwent surgical replacement of an inflatable penile prosthesis (IPP). A cohort of 105 patients who underwent IPP replacement from 2005–2007 was retrieved from the prosthesis database. Approximately 21.9% (23) underwent replacement or revision of their prosthesis because of complications, and were further analyzed. Reason for removal was stratified into infectious and non-infectious (erosion, non-function and patient discomfort). Age, race (African American vs non-African American), smoking history, hypertension, diabetes, coronary artery disease and hyperlipidemia were stratified by reason for removal. Finally, we contacted patients and recorded subjective satisfaction with their IPP. The reason for removal was most commonly because of a non-functional IPP (47.8%), followed by infection (30.4%), erosion (17.4%) and patient discomfort (4.3%). Age and race did not show a significant difference when analyzing reason for replacement (P>0.05). Patients who were smokers (P=0.907) had hypertension (P=0.554), diabetes (P=0.591) or hyperlipidemia (P=0.219) did not have significantly higher infection rates. Approximately 58.3% were satisfied with their prosthesis, 75% would have the surgery performed again and 91.7% would still recommend prosthesis surgery. Device malfunction was the primary reason for replacement/removal at our institution. Despite the complications of prosthesis reoperation, the majority of patients were still satisfied with their prosthesis, would have the surgery performed again and would recommend prosthesis surgery to a friend.
引用
收藏
页码:39 / 42
页数:3
相关论文
共 73 条
  • [1] Minervini A(2006)Outcome of penile prosthesis implantation for treating erectile dysfunction: experience with 504 procedures BJU Int 97 129-309
  • [2] Ralph DJ(2005)Revision washout decreases penile prosthesis infection in revision surgery: a multicenter study J Urol 173 89-undefined
  • [3] Pryor JP(2010)Patient and partner satisfaction after AMS inflatable penile prosthesis implant J Sex Med 7 304-undefined
  • [4] Henry GD(2006)Risk of infection with an antibiotic coated penile prosthesis at device replacement for mechanical failure J Urol 176 2471-undefined
  • [5] Wilson SK(1996)Risk factors for penile prosthetic infection J Urol 156 402-undefined
  • [6] Delk JR(2003)Factors influencing the outcomes of penile prosthesis surgery at a teaching institution Urology 62 918-undefined
  • [7] Carson CC(2004)Tissue ingrowth in penile implants and its effect on repeat penile surgery Int J Impot Res 16 203-undefined
  • [8] Wiygul J(2008)Penile implantation in Europe: successes and complications with 253 implants in Italy and Germany J Sex Med 5 1503-undefined
  • [9] Tornehl C(2003)Inflatable penile prosthesis: site-specific malfunction analysis Int J Impot Res 15 22-undefined
  • [10] Bettocchi C(2001)Penile prosthesis infections Int J Impot Res 13 326-undefined