Influence of optic media of the human eye on the imaging of Argus® II retinal prosthesis with intraoperative spectral-domain optical coherence tomography; [Einfluss der optischen Medien des menschlichen Auges auf die Bildgebung einer Argus®-II-Retinaprothese mit intraoperativer Spectral-Domain optischer Kohärenztomografie]

被引:0
作者
Lytvynchuk L.M. [1 ,3 ]
Falkner-Radler C.I. [2 ,3 ,8 ]
Grzybowski A. [4 ,5 ]
Glittenberg C.G. [3 ]
Shams-Mafi F. [2 ,3 ,8 ]
Ansari-Shahrezaei S. [2 ,3 ,6 ,7 ]
Binder S. [2 ,3 ,7 ,8 ]
机构
[1] Department of Ophthalmology, University Hospital Giessen and Marburg GmbH, Campus Giessen, Justus-Liebig-University Giessen, Friedrichstraße 18, Giessen
[2] Department of Ophthalmology, Rudolf Foundation Hospital, Juchgasse 25, Vienna
[3] Karl Landsteiner Institute for Retinal Research and Imaging, Juchgasse 25, Vienna
[4] Department of Ophthalmology, University of Warmia and Mazury, Olsztyn
[5] Institute for Research in Ophthalmology, Poznan
[6] Department of Ophthalmology, Medical University of Graz, Auenbrugger Platz 1, Graz
[7] Retina Center Vienna, Jacquingasse 41, Vienna
[8] Department of Ophthalmology, Eye Center Donaustadt, Sigmund Freud University, Zschokkegasse 140, Vienna
关键词
Bionic eye; Intraoperative imaging; Pars plana vitrectomy; Postprocessing; Retinitis pigmentosa;
D O I
10.1007/s00717-019-0429-x
中图分类号
学科分类号
摘要
Background: This study aimed to evaluate the influence of the optic media of the human eye on intraoperative spectral-domain optical coherence tomography (iSD-OCT) of an Argus® II retinal prosthesis (AIIRP) during its implantation. Methods: One AIIRP was implanted in a human eye with end-stage retinitis pigmentosa and another one in a test eye. Intraoperative imaging was performed using the Rescan™ 700, a microscope-integrated iSD-OCT system. The feasibility of iSD-OCT imaging for AIIRP implantation was assessed during different surgical steps. Data were post-processed postoperatively using the ImageJ graphic software. Results: The quality of imaging of the AIIRP during its implantation was good and almost the same in the human eye and in the training eye. The histograms showed that the optic media had no impact on the quality of iSD-OCT scans, as the difference between the pixel values was not statistically significant. Additionally, the quality of iSD-OCT imaging of the retina under the AIIRP array was not decreased by the array itself. Conclusion: The iSD-OCT-assisted surgical approach facilitates imaging of the AIIRP during its implantation. Uncompromised human optic media do not reduce the quality of AIIRP array imaging throughout all the surgical steps. The influence of the opaque cornea in long-lasting surgeries on the iSD-OCT scan quality during AIIRP implantation has to be investigated. © 2019, Springer-Verlag GmbH Austria, ein Teil von Springer Nature.
引用
收藏
页码:1 / 9
页数:8
相关论文
共 23 条
[1]  
Hamel C., Retinitis pigmentosa, Orphanet J Rare Dis, 1, (2006)
[2]  
Binder S., Lytvynchuk L.M., Argus II Retina Implantat bei an Retinopathia pigmentosa erblindeter Patientin, Spektrum Augenheilkd, 30, pp. 100-105, (2016)
[3]  
Luo Y., da Cruz L., The Argus(®) II Retinal Prosthesis System, Prog Retin Eye Res, 50, pp. 89-107, (2016)
[4]  
Rizzo S., Belting C., Cinelli L., Allegrini L., Genovese-Ebert F., Barca F., di Bartolo E., The Arguss II Retinal Prosthesis: 12-month outcome from a single-study centre, Am J Ophthalmol, 157, 6, pp. 1282-1290, (2014)
[5]  
Ghodasra D.H., Chen A., Arevalo J.F., Birch D.G., Branham K., Coley B., Dagnelie G., de Juan E., Devenyi R.G., Dorn J.D., Fisher A., Worldwide Argus II implantation: recommendations to optimize patient outcomes, BMC Ophthalmol, 16, 1, (2016)
[6]  
Delyfer M., Gaucher D., Govare M., Cougnard-Gregoire A., Korobelnik J., Ajana S., Mohand-Said S., Ayello-Scheer S., Rezaiguia-Studer F., Dollfus H., Sahel J., Barale P., Adapted surgical procedure for argus II retinal implantation: feasibility, safety, efficiency, and postoperative anatomic findings, Ophthalmol Retin, 2, pp. 276-287, (2018)
[7]  
Weiland J.D., Cho A.K., Humayun M.S., Retinal prostheses: current clinical results and future needs, Ophthalmology, 118, 11, pp. 2227-2237, (2011)
[8]  
Israelsen P.E., Sadda S.R., Dorn J.D., Humayun M.S., Olmos de Koo L.C., Optomap widefield imaging of the argus ii retinal prosthesis in patients with retinitis pigmentosa, Retin Cases Brief Rep, 10, 4, pp. 382-385, (2016)
[9]  
Parmeggiani F., De Nadai K., Piovan A., Binotto A., Zamengo S., Chizzolini M., Optical coherence tomography imaging in the management of the Argus II retinal prosthesis system, Eur J Ophthalmol, 27, 1, pp. e16-e21, (2017)
[10]  
Luo Y.H., Davagnanam I., da Cruz L., MRI brain scan in two patients with the Argus II retinal prothesis, Ophthalmology, 120, 8, (2013)