Necessary conditions for peak resolution in an ion mobility increment spectrometer with a flat drift chamber

被引:0
|
作者
S. V. Shibkov
A. A. Elistratov
L. A. Shcherbakov
机构
[1] Institute of Cryptosystems,
[2] Communications,undefined
[3] and Informatics,undefined
来源
Technical Physics Letters | 2008年 / 34卷
关键词
82.80.-d;
D O I
暂无
中图分类号
学科分类号
摘要
New analytical characteristics are proposed to describe the performance of an ion mobility increment spectrometer (IMIS). The dispersion describes the ability of such a spectrometer to separate ions with close values of the variable component of mobility. The necessary resolution limit with respect to this component characterizes the ability to separately detect different ion species. In accordance with the principle of ion separation in this instrument, it is suggested to redefine the resolving power of IMIS as the inverse of the necessary resolution limit with respect to the variable component of mobility.
引用
收藏
页码:714 / 717
页数:3
相关论文
共 50 条
  • [1] Necessary conditions for peak resolution in an ion mobility increment spectrometer with a flat drift chamber
    Shibkov, S. V.
    Elistratov, A. A.
    Shcherbakov, L. A.
    TECHNICAL PHYSICS LETTERS, 2008, 34 (08) : 714 - 717
  • [2] Analysis of non-linear ion drift in spectrometers of ion mobility increment with cylindrical drift chamber
    Elistratov, A. A.
    Shibkov, S. V.
    Nikolaev, E. N.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2006, 12 (03) : 153 - 160
  • [3] Space charge effect in spectrometers of ion mobility increment with planar drift chamber
    Elistratov, A. A.
    Sherbakov, L. A.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2007, 13 (02) : 115 - 123
  • [4] Space charge effect in spectrometers of ion mobility increment with a cylindrical drift chamber
    Elistratov, A. A.
    Sherbakov, L. A.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2007, 13 (04) : 259 - 272
  • [5] Negative ion formation in laser ion mobility increment spectrometer
    G. E. Kotkovskii
    A. V. Tugaenko
    A. A. Chistyakov
    Technical Physics Letters, 2010, 36 : 276 - 278
  • [6] Negative ion formation in laser ion mobility increment spectrometer
    Kotkovskii, G. E.
    Tugaenko, A. V.
    Chistyakov, A. A.
    TECHNICAL PHYSICS LETTERS, 2010, 36 (03) : 276 - 278
  • [7] High resolution Varying Field Drift Tube Ion Mobility Spectrometer with diffusion autocorrection
    Chen, Xi
    Gandhi, Viraj
    Coots, Joshua
    Fan, Yinghui
    Xu, Liang
    Fukushima, Nobuhiko
    Larriba-Andaluz, Carlos
    JOURNAL OF AEROSOL SCIENCE, 2020, 140
  • [8] Characterization of a high resolution drift tube ion mobility spectrometer with a multi-ion source platform
    Adamov, Alexey
    Mauriala, Timo
    Teplov, Victor
    Laakia, Jaakko
    Pedersen, Christian Schack
    Kotiaho, Tapio
    Sysoev, Alexey A.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 298 (1-3) : 24 - 29
  • [9] Novel design for drift tubes in ion mobility spectrometry for optimised resolution of peak clusters
    Hariharan, Chandrasekhara Bharadwaj
    Seifert, Luzia
    Baumbach, Joerg Ingo
    Vautz, Wolfgang
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2011, 14 (01) : 31 - 38
  • [10] Qualitative analysis of trace constituents by ion mobility increment spectrometer
    Buryakov, IA
    TALANTA, 2003, 61 (03) : 369 - 375