Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function

被引:0
作者
Torleif A. Sandner
Philip Houck
Val M. Runge
Spencer Sincleair
Armin M. Huber
Daniel Theisen
Maximilian F. Reiser
Bernd J. Wintersperger
机构
[1] Ludwig-Maximilians-University,Department of Clinical Radiology, University Hospitals—Campus Grosshadern
[2] Texas A&M University Health Science Center,Department of Cardiology, Scott & White Clinic and Hospital
[3] Texas A&M University Health Science Center,Department of Radiology, Scott & White Clinic and Hospital
来源
European Radiology | 2008年 / 18卷
关键词
Heart; Magnetic resonance; Cine study; Parallel imaging; Volume measurement;
D O I
暂无
中图分类号
学科分类号
摘要
The ability of fast, parallel-imaging-based cine magnetic resonance (MR) to monitor global cardiac function in longitudinal exams at 3 Tesla was evaluated. Seventeen patients with chronic cardiac disease underwent serial cine MR imaging exams (n = 3) at 3 Tesla. Data were acquired in short-axis orientation using cine steady-state free precession (SSFP) with a spatial resolution of 2.5 × 1.9 mm2 at 45 ms temporal resolution. Multislice imaging (three slices/breath-hold) was performed using TSENSE acceleration (R = 3) and standard single-slice cine (non-TSENSE) was performed at identical locations in consecutive breath-holds. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and myocardial mass (MM) of both cine approaches were compared for individual time-points as well as for longitudinal comparison. TSENSE-cine did not show significant differences for EDV (2.6 ml; P = 0.79), ESV (2.2 ml; P = 0.81), EF (−0.3%; P = 0.95) and MM (2.4 g; P = 0.72) in comparison with non-TSENSE. Longitudinal ANOVA analysis did not reveal significant differences for any parameter, neither for non-TSENSE data (all P > 0.7) nor for TSENSE data (all P > 0.9). Multifactorial ANOVA showed non-significant differences (all P > 0.7) at comparable data variances. Data acquisition was significantly shortened using TSENSE. Threefold accelerated multislice cine at 3 Tesla allows accurate assessment of volumetric LV data and accurate longitudinal monitoring of global LV function at a substantially shorter overall examination time.
引用
收藏
页码:2095 / 2101
页数:6
相关论文
共 151 条
[1]  
St John Sutton M(2003)Left ventricular remodeling and ventricular arrhythmias after myocardial infarction Circulation 107 2577-2582
[2]  
Lee D(2005)Guidelines for the diagnosis and treatment of chronic heart failure: executive summary (update 2005): The Task Force for the Diagnosis and Treatment of Chronic Heart Failure of the European Society of Cardiology Eur Heart J 26 1115-1140
[3]  
Rouleau JL(2003)Predictors of late development of heart failure in stable survivors of myocardial infarction: the CARE study J Am Coll Cardiol 42 1446-1453
[4]  
Goldman S(2002)Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy Am J Cardiol 90 29-34
[5]  
Plappert T(2000)Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance J Cardiovasc Magn Reson 2 271-278
[6]  
Braunwald E(2006)Cardiac steady-state free precession CINE magnetic resonance imaging at 3.0 tesla: impact of parallel imaging acceleration on volumetric accuracy and signal parameters Invest Radiol 41 141-147
[7]  
Pfeffer MA(2007)Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function Eur Radiol 17 73-80
[8]  
Swedberg K(1997)Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays Magn Reson Med 38 591-603
[9]  
Cleland J(2002)Generalized autocalibrating partially parallel acquisitions (GRAPPA) Magn Reson Med 47 1202-1210
[10]  
Dargie H(1999)SENSE: sensitivity encoding for fast MRI Magn Reson Med 42 952-962