Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty

被引:0
作者
Christophe Chevillotte
Vincent Pibarot
Jean-Paul Carret
Jacques Bejui-Hugues
Olivier Guyen
机构
[1] Hôpital Edouard Herriot,Department of Orthopedic Surgery, Pavillon T
[2] Université Claude Bernard,Laboratoire de Biomécanique des Chocs, LBMC–INRETS URMT 9406
来源
International Orthopaedics | 2011年 / 35卷
关键词
Femoral Component; Femoral Neck Fracture; Acetabular Component; Acetabular Fracture; Radiolucent Line;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to evaluate the first 100 cementless ceramic-on-ceramic total hip arthroplasty (THA) performed at our institution with more than nine years of follow-up. Clinical evaluation was performed using Harris hip score. Radiological evaluation was performed by two surgeons. Four patients were lost to follow-up. Harris hip score significantly improved at latest follow-up. Radiological analysis showed calcar osteolysis for 75 patients and one cup loosening. One patient required a revision five years postoperatively for cup loosening. Based on these results and the routine use of a navigation system to optimise positioning of the implants, we advocate the use of uncemented hydroxyapatite coated ceramic-on-ceramic THA in young and active patients in our current practice.
引用
收藏
页码:1599 / 1604
页数:5
相关论文
共 50 条
  • [41] Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up
    M. Schramm
    F. Keck
    D. Hohmann
    R. P. Pitto
    Archives of Orthopaedic and Trauma Surgery, 2000, 120 : 407 - 412
  • [42] Ceramic- on- Ceramic in Total Hip Replacement Revision
    Cucchi, Davide
    Gathen, Martin
    Streicher, Robert
    Wirtz, Dieter Christian
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2018, 156 (03): : 272 - 280
  • [43] Clinical and radiographic outcomes of a trabecular titanium™ acetabular component in hip arthroplasty: results at minimum 5 years follow-up
    Loris Perticarini
    Giacomo Zanon
    Stefano Marco Paolo Rossi
    Francesco M. Benazzo
    BMC Musculoskeletal Disorders, 16
  • [44] 6 years follow-up of hip revision surgery
    Orban, H.
    Stan, G.
    Gheorghiu, N.
    Dragusanu, M.
    Mares, E.
    Orban, C.
    CHIRURGIA, 2012, 107 (02) : 226 - 230
  • [45] Midterm Results of Large Diameter Biolox Forte Ceramic Head on Delta Ceramic Liner Articulation in Total Hip Arthroplasty
    Kang, Bun-Jung
    Ha, Yong-Chan
    Hwang, Sun-Chul
    Lee, Young-Kyun
    Koo, Kyung-Hoi
    JOURNAL OF ARTHROPLASTY, 2014, 29 (12) : 2412 - 2414
  • [46] Total Hip Arthroplasty for Failed Treatment of Acetabular Fractures A 5-Year Follow-Up Study
    Zhang, Liang
    Zhou, Yixin
    Li, Yujun
    Xu, Hui
    Guo, Xiaozhong
    Zhou, Yixiong
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08) : 1189 - 1193
  • [47] New polyethylenes in total hip arthroplasty a 20-to 22-year follow-up study
    Garcia-Rey, E.
    Cruz-Pardos, A.
    Saldana, L.
    BONE & JOINT JOURNAL, 2022, 104B (09) : 1032 - 1038
  • [48] Cementless Total Hip Arthroplasty With a High Hip Center for Hartofilakidis Type B Developmental Dysplasia of the Hip: Results of Midterm Follow-Up
    Chen, Min
    Luo, Zheng-Liang
    Wu, Ke-Rong
    Zhang, Xiao-Qi
    Ling, Xiao-Dong
    Shang, Xi-Fu
    JOURNAL OF ARTHROPLASTY, 2016, 31 (05) : 1027 - 1034
  • [49] Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up
    Alexander M. Kress
    Rainer Schmidt
    Ulrich Holzwarth
    Raimund Forst
    Lutz A. Mueller
    International Orthopaedics, 2011, 35 : 195 - 200
  • [50] Total hip arthroplasty for failed internal fixation of femoral neck fracture: a retrospective study with 2–14 years’ follow-up of 345 patients
    Hanpeng Lu
    Niu Zhu
    Tingxian Ling
    Jian Cao
    Hong Xu
    Kai Zhou
    Enze Zhao
    Zongke Zhou
    Journal of Orthopaedic Surgery and Research, 18