Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty

被引:0
|
作者
Christophe Chevillotte
Vincent Pibarot
Jean-Paul Carret
Jacques Bejui-Hugues
Olivier Guyen
机构
[1] Hôpital Edouard Herriot,Department of Orthopedic Surgery, Pavillon T
[2] Université Claude Bernard,Laboratoire de Biomécanique des Chocs, LBMC–INRETS URMT 9406
来源
International Orthopaedics | 2011年 / 35卷
关键词
Femoral Component; Femoral Neck Fracture; Acetabular Component; Acetabular Fracture; Radiolucent Line;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to evaluate the first 100 cementless ceramic-on-ceramic total hip arthroplasty (THA) performed at our institution with more than nine years of follow-up. Clinical evaluation was performed using Harris hip score. Radiological evaluation was performed by two surgeons. Four patients were lost to follow-up. Harris hip score significantly improved at latest follow-up. Radiological analysis showed calcar osteolysis for 75 patients and one cup loosening. One patient required a revision five years postoperatively for cup loosening. Based on these results and the routine use of a navigation system to optimise positioning of the implants, we advocate the use of uncemented hydroxyapatite coated ceramic-on-ceramic THA in young and active patients in our current practice.
引用
收藏
页码:1599 / 1604
页数:5
相关论文
共 50 条
  • [31] The Synergy cementless femoral stem in primary total hip arthroplasty at a minimum follow-up of 15 years
    De Martino, I.
    De Santis, V.
    D'Apolito, R.
    Sculco, P. K.
    Cross, M. B.
    Gasparini, G.
    BONE & JOINT JOURNAL, 2017, 99B (01): : 29 - 36
  • [32] First Series of Exeter Small Stem Primary Total Hip Arthroplasty Minimum 5 Years of Follow-Up
    Tai, Cheh Chin
    Nam, Hui Yin
    Abbas, Azlina Amir
    Merican, Azhar M.
    Choon, Siew Kit
    JOURNAL OF ARTHROPLASTY, 2009, 24 (08): : 1200 - 1204
  • [34] A long-term follow-up of 60 Lord total hip arthroplasties in rheumatic disease: a mean follow-up of 14 years
    C. C. Lybäck
    C. O. Lybäck
    A. Kyrö
    H. J. Kautiainen
    E. A. Belt
    International Orthopaedics, 2006, 30 : 391 - 394
  • [35] Two-Year Results of Ceramic-on-Ceramic Hip Resurfacing in an International Multicenter Cohort
    Lin, David
    Xu, Joshua
    Weinrauch, Patrick
    Young, David A.
    De Smet, Koen
    Manktelow, Andrew
    Beaule, Paul E.
    Walter, William L.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (11): : 2800 - 2806
  • [36] Total Hip Arthroplasty with Use of the Cementless Zweymuller Alloclassic System A Concise Follow-up, at a Minimum of 25 Years, of a Previous Report
    Cruz-Pardos, Ana
    Garcia-Rey, Eduardo
    Garcia-Cimbrelo, Eduardo
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (22): : 1927 - 1931
  • [37] Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years
    Stefan Lakemeier
    Guenter Aurand
    Nina Timmesfeld
    Thomas J Heyse
    Susanne Fuchs-Winkelmann
    Markus D Schofer
    BMC Musculoskeletal Disorders, 11
  • [38] Resurfacing arthroplasty of the hip for avascular necrosis of the femoral head A MINIMUM FOLLOW-UP OF FOUR YEARS
    Bose, V. C.
    Baruah, B. D.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (07): : 922 - 928
  • [39] Hybrid total hip arthroplasty using specifically-designed stems for patients with developmental dysplasia of the hip. A minimum five-year follow-up study
    Hiroshi Ito
    Hiromasa Tanino
    Yasuhiro Yamanaka
    Toshiki Nakamura
    Takeo Matsuno
    International Orthopaedics, 2011, 35 : 1289 - 1294
  • [40] Mid-Term Results of Third-Generation Alumina-on-Alumina Ceramic Bearings in Cement less Total Hip Arthroplasty A Ten-Year Minimum Follow-up
    Yeung, Eric
    Bott, Paul Thornton
    Chana, Rishi
    Jackson, Mark P.
    Holloway, Ian
    Walter, William L.
    Zicat, Bernard A.
    Walter, William K.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (02): : 138 - 144