Double-Balloon Catheter for Isolated Liver Perfusion: An Experimental Study

被引:0
|
作者
Wojciech Cwikiel
Lennart Bergqvist
Jan Harnek
机构
[1] Centre for Medical Imaging and Physiology,
[2] University Hospital,undefined
[3] S-22185 Lund,undefined
[4] Lund,undefined
[5] Sweden,undefined
[6] Department of Radiation Physics,undefined
[7] University Hospital,undefined
[8] S-221 85 Lund,undefined
[9] Sweden,undefined
来源
CardioVascular and Interventional Radiology | 2001年 / 24卷
关键词
Key words: Liver metastases—Isolated liver perfusion—Experimental model—Double-balloon catheter;
D O I
暂无
中图分类号
学科分类号
摘要
Purpose: Further development of a previously described interventional method for isolated liver perfusion (ILP) with a new double-lumen balloon catheter, and evaluation of the side-effects of such isolation.
引用
收藏
页码:191 / 191
相关论文
共 50 条
  • [1] Double-balloon catheter for isolated liver perfusion: An experimental study
    Cwikiel, W
    Bergqvist, L
    Harnek, J
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (03) : 191 - 193
  • [2] URETERIC STONE EXTRACTION BY A NEW DOUBLE-BALLOON CATHETER - AN EXPERIMENTAL-STUDY
    SHIHATA, AA
    GREENE, JE
    JOURNAL OF UROLOGY, 1983, 129 (03): : 616 - 620
  • [3] FEMALE URETHRAL DIVERTICULA - DOUBLE-BALLOON CATHETER STUDY
    GREENBERG, M
    STONE, D
    COCHRAN, ST
    BRUSKEWITZ, R
    PAGANI, JJ
    RAZ, S
    BARBARIC, ZM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 136 (02) : 259 - 264
  • [4] THE APPLICATION OF DOUBLE-BALLOON CATHETER FOR RENAL VENOGRAPHY
    INAGAKI, Y
    AMANO, I
    TERAMACHI, N
    FUJITA, T
    OSHIMA, S
    ARTIFICIAL ORGANS, 1981, 5 (03) : 329 - 329
  • [5] Treatment of chronic bacterial prostatitis by transurethral perfusion with double-balloon and triple-channel catheter: A control study
    Huang, WD
    Xu, B
    Huang, WJ
    ANDROLOGY IN THE 21ST CENTURY, SHORT COMMUNICATIONS, 2001, : 659 - 664
  • [6] STEPWISE CORONARY DILATATION (PTCA) WITH A DOUBLE-BALLOON CATHETER
    KAPPENBERGER, L
    ZEITSCHRIFT FUR KARDIOLOGIE, 1982, 71 (03): : 190 - 190
  • [7] Double-balloon catheter compared with single-balloon catheter for induction of labor with a scarred uterus
    Xing, Yanping
    Li, Na
    Ji, Qiumei
    Hong, Lingling
    Wang, Xuezhen
    Xing, Baoheng
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2019, 243 : 139 - 143
  • [8] Local delivery of paclitaxel using the double-balloon perfusion catheter before stenting in the porcine coronary artery
    Oberhoff, M
    Herdeg, C
    Al Ghobainy, R
    Cetin, S
    Küttner, A
    Horch, B
    Baumbach, A
    Karsch, KR
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (04) : 562 - 568
  • [9] Intracoronary delivery of paclitaxel after experimental balloon angioplasty using the double balloon perfusion catheter
    Oberhoff, MA
    Cetin, S
    Al Gobainy, R
    Herdeg, C
    Schroeder, S
    Horch, B
    Baumbach, A
    Karsch, KR
    CIRCULATION, 2000, 102 (18) : 564 - +
  • [10] EXTRACTION OF URETERAL CALCULI USING SPECIAL DOUBLE-BALLOON CATHETER
    PETROPOULOS, P
    HADJI, M
    HAHNLOSER, P
    HELVETICA CHIRURGICA ACTA, 1979, 46 (03) : 365 - 367