Comparative thermodynamic analysis on design performance characteristics of solid oxide fuel cell/gas turbine hybrid power systems

被引:0
作者
Sung Ku Park
Won Jun Yang
Joon Hee Lee
Tong Seop Kim
机构
[1] Graduate School,Department of Mechanical Engineering
[2] Inha University,undefined
[3] Inha University,undefined
来源
Journal of Mechanical Science and Technology | 2007年 / 21卷
关键词
Solid Oxide Fuel Cell; Gas Turbine; Design; Ambient Pressure System; Pressurized System; Exergy Destruction;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents analysis results for the hybrid power system combining a solid oxide fuel cell and a gas turbine. Two system layouts, with the major difference being the operating pressure of the fuel cell, were considered and their thermodynamic design performances were compared. Critical temperature parameters affecting the design performances of the hybrid systems were considered as constraints for the system design. In addition to energy analysis, exergy analysis has been adopted to examine the performance differences depending on system layouts and design conditions. Under a relaxed temperature constraint on the cell, the ambient pressure system exhibits relatively larger power capacity but requires both higher cell temperature and temperature rise at the cell for a given gas turbine design condition. The pressurized system utilizes the high temperature gas from the fuel cell more effectively than the ambient pressure system, and thus exhibits better efficiency. Under a restricted temperature constraint on the cell, the efficiency advantage of the pressurized system becomes manifested.
引用
收藏
页码:291 / 302
页数:11
相关论文
共 23 条
[1]  
Chan S. H.(2002)Energy and Exergy Analysis of Simple Solid-Oxide Fuel-Cell Power Systems Journal of Power Sources 103 188-200
[2]  
Low C. F.(2000)Internal Reforming Solid Oxide Fuel Cell-Gas Turbine Combined Cycle (IRSOFC-GT), Part A: Cell Model and Cycle Thermodynamic Analysis Trans. ASME, Journal of Engineering for Gas Turbines and Power 122 27-35
[3]  
Ding O. L.(1994)Exergy Analysis: Principles and Practice Trans. ASME, Journal of Engineering for Gas Turbines and Power 116 285-290
[4]  
Massardo A. F.(2006)Performance Analysis on Various System Layouts for the Combination of an Ambient Pressure Molten Carbonate Fuel Cell and a Gas Turbine Journal of Power Sources 158 455-463
[5]  
Lubelli F.(2005)Performance Analysis of a Solid Oxide Fuel Cell/Micro Gas Turbine Hybrid Power System Based on a Quasi-Two Dimensional Model Journal of Power Sources 142 30-42
[6]  
Moran M. J.(2005)Comparative Performance Analysis of Pressurized Solid Oxide Fuel Cell/Gas Turbine Hybrid Systems Considering Different Cell Inlet Preheating Methods Trans. of KSME B 29 722-729
[7]  
Sciubba E.(2006)Design Performance Analysis of Pressurized Solid Oxide Fuel Cell/Gas Turbine Hybrid Systems Considering Temperature Constraints Journal of Power Sources 160 462-473
[8]  
Oh K. S.(undefined)undefined undefined undefined undefined-undefined
[9]  
Kim T. S.(undefined)undefined undefined undefined undefined-undefined
[10]  
Song T.W.(undefined)undefined undefined undefined undefined-undefined