Sensitive immunoassay for the β-agonist ractopamine based on glassy carbon electrode modified with gold nanoparticles and multi-walled carbon nanotubes in a film of poly-arginine

被引:0
|
作者
Ying Zhou
Peilong Wang
Xiaoou Su
Hong Zhao
Yujian He
机构
[1] Chinese Academy of Agricultural Sciences,Key Laboratory of Agro
[2] University of Chinese Academy of Sciences,Product Safety and Quality, Ministry of Agriculture, Institute of Quality Standards & Testing Technology for Agro
[3] Peking University,Products
来源
Microchimica Acta | 2014年 / 181卷
关键词
Ractopamine; Immunosensor; Multi-walled carbon nanotubes; Gold nanoparticles; Electrochemical impedance spectroscopy; Differential pulse voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
We are presenting an electrochemical immunosensor for the determination of the β-agonist and food additive ractopamine. A glassy carbon electrode (GCE) was modified with gold nanoparticles and a film of a composite made from poly(arginine) and multi-walled carbon nanotubes. Antibody against ractopamine was immobilized on the surface of the modified GCE which then was blocked with bovine serum albumin. The assembly of the immunosensor was followed by electrochemical impedance spectroscopy. Results demonstrated that the semicircle diameter increases, indicating that the film formed on the surface hinders electron transfer due to formation of the antibody-antigen complex on the modified electrode. Under optimal conditions, the peak current obtained by differential pulse voltammetry decreases linearly with increasing ractopamine concentrations in the 0.1 nmol•L−1 to 1 μmol•L−1 concentration range. The lower detection limit is 0.1 nmol•L−1. The sensor displays good stability and reproducibility. The method was applied to the analysis of spiked swine feed samples and gave satisfactory results.
引用
收藏
页码:1973 / 1979
页数:6
相关论文
共 50 条
  • [1] Sensitive immunoassay for the β-agonist ractopamine based on glassy carbon electrode modified with gold nanoparticles and multi-walled carbon nanotubes in a film of poly-arginine
    Zhou, Ying
    Wang, Peilong
    Su, Xiaoou
    Zhao, Hong
    He, Yujian
    MICROCHIMICA ACTA, 2014, 181 (15-16) : 1973 - 1979
  • [2] Immunoassay for netrin 1 via a glassy carbon electrode modified with multi-walled carbon nanotubes, thionine and gold nanoparticles
    Xu, Wailan
    He, Junlin
    Gao, Liuliu
    Zhang, Jing
    Yu, Chao
    MICROCHIMICA ACTA, 2015, 182 (13-14) : 2115 - 2122
  • [3] Immunoassay for netrin 1 via a glassy carbon electrode modified with multi-walled carbon nanotubes, thionine and gold nanoparticles
    Wailan Xu
    Junlin He
    Liuliu Gao
    Jing Zhang
    Chao Yu
    Microchimica Acta, 2015, 182 : 2115 - 2122
  • [4] Construction of Biosensor Based on Glassy Carbon Electrode Modified by Composite Film of Multi-Walled Carbon Nanotubes and Poly(ethylenimine)
    Sun, Tao
    Zheng, Haitao
    Li, Wei-wei
    Liu, Pu
    Ruan, Yanli
    Suye, Shin-ichiro
    ADVANCED MATERIAL SCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2011, 675-677 : 235 - +
  • [5] Electrochemical synthesis of gold nanoparticles on the surface of multi-walled carbon nanotubes with glassy carbon electrode and their application
    Y. Z. Song
    X. Li
    Y. Song
    Z. P. Cheng
    H. Zhong
    J. M. Xu
    J. S. Lu
    C. G. Wei
    A. F. Zhu
    F. Y. Wu
    J. Xu
    Russian Journal of Physical Chemistry A, 2013, 87 : 74 - 79
  • [6] Electrochemical synthesis of gold nanoparticles on the surface of multi-walled carbon nanotubes with glassy carbon electrode and their application
    Song, Y. Z.
    Li, X.
    Song, Y.
    Cheng, Z. P.
    Zhong, H.
    Xu, J. M.
    Lu, J. S.
    Wei, C. G.
    Zhu, A. F.
    Wu, F. Y.
    Xu, J.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2013, 87 (01) : 74 - 79
  • [7] Electrochemical immunosensor for casein based on gold nanoparticles and poly(L-Arginine)/multi-walled carbon nanotubes composite film functionalized interface
    Cao, Qian
    Zhao, Hong
    Yang, Yimin
    He, Yujian
    Ding, Nan
    Wang, Jian
    Wu, Zhijiao
    Xiang, Kaixiang
    Wang, Guangwei
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) : 3469 - 3474
  • [8] Indirect determination of sulfite using a polyphenol oxidase biosensor based on a glassy carbon electrode modified with multi-walled carbon nanotubes and gold nanoparticles within a poly(allylamine hydrochloride) film
    Sartori, Elen Romao
    Vicentini, Fernando Campanha
    Fatibello-Filho, Orlando
    TALANTA, 2011, 87 : 235 - 242
  • [9] Sensitive determination of pesticide imidacloprid using a glassy carbon electrode modified with a film composed of multi-walled carbon nanotubes and poly(aspartic acid)
    Liu, Jie
    Li, Yinfeng
    Song, Ge
    Zhang, Kai
    Ye, Baoxian
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (09) : 884 - 900
  • [10] Electrochemical properties and the determination of nicotine at a multi-walled carbon nanotubes modified glassy carbon electrode
    Huayu Xiong
    Yunfei Zhao
    Peng Liu
    Xiuhua Zhang
    Shengfu Wang
    Microchimica Acta, 2010, 168 : 31 - 36