Radiation shielding parameters of some antioxidants using Monte Carlo method

被引:0
|
作者
Huseyin Ozan Tekin
Mesut Karahan
Turker Tekin Erguzel
Tugba Manici
Muhsin Konuk
机构
[1] Uskudar University,Vocational School of Health Services, Radiotherapy Department
[2] Uskudar University,Faculty of Engineering and Natural Sciences, Department of Bioengineering
[3] Uskudar University,Faculty of Engineering and Natural Sciences, Department of Computer Engineering
[4] Uskudar University Istanbul,Medical Radiation Research Center (USMERA)
[5] Uskudar University,Faculty of Engineering and Natural Sciences, Department of Molecular Biology and Genetics
来源
关键词
Antioxidants; Mass attenuation coefficients; MCNPX;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, radiation shielding parameters such as mass attenuation coefficients and half value layer (HVL) of some antioxidants are investigated using MCNPX (version 2.4.0). The validation of the generated MCNPX simulation geometry for antioxidant structures is provided by comparing the results with standard WinXcom data for radiation mass attenuation coefficients of antioxidants. Very good agreement between WİNXCOM and MCNPX was obtained. The results from the validated geometry were used to calculate the shielding parameters of different antioxidants. The radiation attenuation properties of each antioxidant were compared with each other. The results showed that, on average, the highest and the lowest radiation mass attenuation coefficients were observed on hesperidin and delphinidin chloride, respectively. It can be concluded that Monte Carlo simulation is a strong tool and an alternate method where experimental investigations are not possible and a standard simulation setup can be used in further studies for different biological structures. It can also be concluded that the obtained results from this study are very useful for radiology and radiotherapy applications where antioxidants are frequently used.
引用
收藏
页码:579 / 590
页数:11
相关论文
共 50 条
  • [31] Performance and feasibility evaluation for radiation shielding of metal oxides: Monte Carlo simulation
    Kwon, Da-Eun
    Han, Dong-Hee
    Jung, Kyung-Hwan
    Lee, Seung-Jae
    Kim, Jang-Oh
    Baek, Cheol-Ha
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2023, 82 (08) : 813 - 817
  • [32] SHIELDING OF STRUCTURES AGAINST INITIAL NUCLEAR RADIATION - MONTE-CARLO METHODOLOGY
    BEER, M
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1979, 33 (NOV): : 669 - 670
  • [33] MULASSIS - Monte Carlo radiation shielding simulation for space applications made easy
    Truscott, P
    Lei, F
    Dyer, C
    Quaghebeur, B
    Heyndericks, D
    Nieminen, P
    Evans, H
    Daly, E
    Mohammadzadeh, A
    Hopkinson, G
    PROCEEDINGS OF THE 7TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS, 2004, 536 : 191 - 196
  • [35] Requirements for Monte Carlo Method during Radiation Shielding Optimization Design of Advanced PWR Nuclear Power Plants
    Lyu W.
    Xiong J.
    Liu J.
    Tang S.
    Hedongli Gongcheng/Nuclear Power Engineering, 2020, 41 (05): : 173 - 177
  • [37] Calculation of time-dependent neutronic parameters using Monte Carlo method
    Shayesteh, M.
    Shahriari, M.
    ANNALS OF NUCLEAR ENERGY, 2009, 36 (07) : 901 - 909
  • [38] Monte Carlo simulations of radiation shielding by rare-earth/polypropylene composites
    Cui, Tongyan
    Wang, Shuilian
    Zhang, Anying
    Wang, Rui
    Ma, Zhongjian
    Jia, Qingxiu
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2023, 178 (9-10): : 1269 - 1281
  • [39] Intra-operative radiation therapy optimization using the Monte Carlo method
    Rosetti, M
    Benassi, M
    Bruzzaniti, V
    Bufacchi, A
    D'Andrea, M
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 455 - 460
  • [40] Determination of correction factors in beta radiation beams using Monte Carlo method
    Polo, Ivon Oramas
    Santos, William de Souza
    Caldas, Linda V. E.
    APPLIED RADIATION AND ISOTOPES, 2018, 140 : 50 - 54