In this paper, radiation shielding parameters such as mass attenuation coefficients and half value layer (HVL) of some antioxidants are investigated using MCNPX (version 2.4.0). The validation of the generated MCNPX simulation geometry for antioxidant structures is provided by comparing the results with standard WinXcom data for radiation mass attenuation coefficients of antioxidants. Very good agreement between WİNXCOM and MCNPX was obtained. The results from the validated geometry were used to calculate the shielding parameters of different antioxidants. The radiation attenuation properties of each antioxidant were compared with each other. The results showed that, on average, the highest and the lowest radiation mass attenuation coefficients were observed on hesperidin and delphinidin chloride, respectively. It can be concluded that Monte Carlo simulation is a strong tool and an alternate method where experimental investigations are not possible and a standard simulation setup can be used in further studies for different biological structures. It can also be concluded that the obtained results from this study are very useful for radiology and radiotherapy applications where antioxidants are frequently used.
引用
收藏
页码:579 / 590
页数:11
相关论文
共 50 条
  • [21] Estimating metabolic pathways parameters using distributed Monte Carlo method
    Lebioda, Pawel
    Bala, Piotr
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2008, PT 2, PROCEEDINGS, 2008, 5073 : 987 - 999
  • [22] Monte Carlo shielding design with a large perturbation calculation method
    Tan, Wanbin
    Sun, Guangyao
    Long, Pengcheng
    Wu, Bin
    Song, Jing
    ANNALS OF NUCLEAR ENERGY, 2020, 138 (138)
  • [23] Applications of Monte Carlo method in radiation medicine
    China Institute of Atomic Energy, Beijing 102413, China
    Qinghua Daxue Xuebao, 2007, SUPPL. 1 (907-909):
  • [24] Radiation interaction parameters of dosimetric importance for some commonly used compensators in IMRT using Monte Carlo simulation code
    Kumar, Ashok
    Kaur, Ramandeep
    Dong, M. G.
    Sayyed, M., I
    Tekin, H. O.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (04) : 1321 - 1343
  • [25] Studies on the Photon Interaction Parameters for Some Vitamins Using Monte Carlo Simulation
    Vahabi, Seyed Milad
    Zafarghandi, Mojtaba Shamsaie
    Bahreinipour, Mostean
    JOURNAL OF TESTING AND EVALUATION, 2019, 47 (06) : 4513 - 4522
  • [26] SOME APPLICATIONS OF THE MONTE-CARLO METHOD
    MURRAY, FJ
    JOURNAL OF THE OPERATIONS RESEARCH SOCIETY OF AMERICA, 1953, 1 (02): : 75 - 75
  • [27] Gamma Shielding Properties of Erbium Zinc Tellurite Glass System Using Monte Carlo Method
    Tekin, Huseyin Ozan
    Singh, Vishwanath P.
    Altunsoy, Elif Ebru
    Karahan, Mesut
    Sayyed, M., I
    Erguzel, Turker Tekin
    Kasikci, Emel Serdaroglu
    Konuk, Muhsin
    JOURNAL OF TESTING AND EVALUATION, 2020, 48 (02) : 1252 - 1261
  • [28] NCT treatment room dose determinations using the Monte Carlo adjoint shielding (MASH) method
    Rydin, RA
    Hubbard, TR
    Mulder, RU
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 629 - 633
  • [29] Using Markov chain Monte Carlo methods for estimating parameters with gravitational radiation data
    Christensen, N
    Meyer, R
    PHYSICAL REVIEW D, 2001, 64 (02):
  • [30] Performance and feasibility evaluation for radiation shielding of metal oxides: Monte Carlo simulation
    Da-Eun Kwon
    Dong-Hee Han
    Kyung-Hwan Jung
    Seung-Jae Lee
    Jang-Oh Kim
    Cheol-Ha Baek
    Journal of the Korean Physical Society, 2023, 82 : 813 - 817