Electrochemical sensing of hydrogen peroxide using a glassy carbon electrode modified with multiwalled carbon nanotubes and zein nanoparticle composites: application to HepG2 cancer cell detection

被引:0
作者
Hamed Tavakkoli
Morteza Akhond
Gholam Abbas Ghorbankhani
Ghodratollah Absalan
机构
[1] Shiraz University,Department of Chemistry, College of Sciences
[2] Shiraz University,Division of Biotechnology, Department of Pathobiology, School of Veterinary Medicine
来源
Microchimica Acta | 2020年 / 187卷
关键词
Electrochemical sensor; Nanocomposite; Enzyme-free; Carbon nanotubes; Protein based biopolymers; Cancer detection;
D O I
暂无
中图分类号
学科分类号
摘要
A nanobiocomposite was prepared from multiwalled carbon nanotubes and zein nanoparticles. It was dispersed in water/ethanol and drop cast onto a glassy carbon electrode. The modified electrode can be used for electroreduction of H2O2 (typically at a working potential of −0.71 V vs. Ag/AgCl). The electrochemical properties of the electrode were investigated by cyclic voltammetry, linear sweep voltammetry, chronoamperometry and electrochemical impedance spectroscopy. Response to H2O2 is linear in the 0.049 to 22 μM concentration range, and the detection limit is 35 nM at pH 7.0. The sensor was successfully utilized for the measurement of H2O2 in a synthetic urine sample, and for monitoring the release of H2O2 from human dermal fibroblasts and human hepatocellular carcinoma cells.
引用
收藏
相关论文
共 120 条
  • [11] Schreml S(2010)Nano-encapsulation method for high selectivity sensing of hydrogen peroxide inside live cells Anal Chem 82 2165-2169
  • [12] Lee E(2014)Immobilizing gold nanoparticles in mesoporous silica covered reduced graphene oxide: a hybrid material for cancer cell detection through hydrogen peroxide sensing ACS Appl Mater Interfaces 6 13648-13656
  • [13] Lee H(2018)Direct electroiodimetric sensing of reducing biomolecules using a modified multiwall carbon nanotube/ionic liquid paste electrode by tetra-n-octylammonium triiodide Electrochim Acta 292 477-488
  • [14] Kim YK(2013)Electrochemical determination of ascorbic acid using modified glassy carbon electrode by multiwall carbon nanotube-nafion in chloroacetic acid media Asian J Chem 25 119-124
  • [15] Sohn K(2012)Determination of ascorbic acid by a modified multiwall carbon nanotube paste electrode using cetrimonium iodide/iodine Turk J Chem 36 645-658
  • [16] Lee K(2011)Preparation of tetraheptylammonium iodide-iodine graphite-multiwall carbon nanotube paste electrode: electrocatalytic determination of ascorbic acid in pharmaceuticals and foods Anal Sci 27 929-935
  • [17] Zhang W(2012)Electrochemical based biosensors Biosensors 2 269-272
  • [18] Liu W(2008)Chemical oxidation of multiwalled carbon nanotubes Carbon 46 833-840
  • [19] Li P(2015)A review on protein functionalized carbon nanotubes J Appl Biomater Funct Mater 13 301-312
  • [20] Huang F(2015)Non-covalent polymer wrapping of carbon nanotubes and the role of wrapped polymers as functional dispersants Sci Technol Adv Mater 16 024802-354