Development of micro-vibrating flow pumps using MEMS technologies

被引:0
|
作者
Osman Omran Osman
Hirofumi Shintaku
Satoyuki Kawano
机构
[1] Osaka University,Department of Mechanical Science and Bioengineering, Graduate School of Engineering Science
来源
Microfluidics and Nanofluidics | 2012年 / 13卷
关键词
Micropump; Vibrating flow pump; Valve; MEMS; Micro-PIV;
D O I
暂无
中图分类号
学科分类号
摘要
In the present paper, we propose a micro-vibrating flow pump (micro-VFP), which is a novel micropump. The micro-VFP is constructed using an actively vibrating valve that has a cantilever-like structure fixed on a wall of a microchannel and a slit orifice downstream. The slit orifice is designed to make the flow asymmetric around the vibrating valve and to effectively generate a net flow in one direction. At the same time, the valve works as an actuator to induce liquid flow in the microchannel. Since the valve is made of a flexible material including magnetic particles, it is manipulated by changing the magnetic field from outside the micro-VFP. This design allows external operation of the micro-VFP without any electrical or mechanical connections. In addition, the micro-VFP, which realizes pumping with a chamber free design, is advantageous for implementation in a small space. In order to demonstrate its basic pumping performance, a prototype micro-VFP was fabricated in a microchannel with a cross section of 240 μm × 500 μm using microelectromechanical systems technologies. The vibration characteristics of the valve were investigated using a high-speed camera. The pump performance at various actuation frequencies in the range of 5 to 25 Hz was evaluated by measuring the hydrostatic head and the flow rate. The proposed micro-VFP design exhibited an increase in performance with the driving frequency and had a maximum shut-off pressure of 3.8 ± 0.4 Pa and a maximum flow rate of 0.38 ± 0.02 μl/min at 25 Hz. Furthermore, in order to clarify the detailed pumping process, the flow characteristics around the vibrating valve were investigated by analyzing the velocity field based on micron-resolution particle image velocimetry (micro-PIV). The validity of the hydrostatic measurement was confirmed by comparing the volume flow rate with that estimated from micro-PIV data. The present study revealed the basic performance of the developed micro-VFP.
引用
收藏
页码:703 / 713
页数:10
相关论文
共 50 条
  • [21] Testing of Cementitious Materials Using a Dynamic MEMS Micro Rheometer
    Kim, Yong-Sik
    Dagalakis, Nicholas G.
    Ferraris, Chiara
    Martys, Nicos S.
    SCC 2016 - 8TH INTERNATIONAL RILEM SYMPOSIUM ON SELF-COMPACTING CONCRETE, 2016, 100 : 159 - 169
  • [22] Micro flow cytometer chip integrated with micro-pumps/micro-valves for multi-wavelength cell counting and sorting
    Chang, Chen-Min
    Hsiung, Suz-Kai
    Lee, Gwo-Bin
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2007, 46 (5A): : 3126 - 3134
  • [23] Design of flow based micro electro mechanical systems MEMS energy harvester
    Shinde, Swapnil
    Pandey, Manoj
    JOURNAL OF COUPLED SYSTEMS AND MULTISCALE DYNAMICS, 2018, 6 (04) : 282 - 290
  • [24] Development of Gas Meter based on MEMS Thermal Flow Sensor
    Wu, Chenguang
    Liu, Genli
    Zhai, Yuan
    Xiang, Yi
    Bai, Junjie
    Shi, Jinliang
    Wu, Ying
    Zheng, Fuzhong
    2019 14TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (IEEE-NEMS 2019), 2019, : 192 - 195
  • [25] New MEMS Based Micro Gripper Using SMA for Micro Level Object Manipulation and Assembling
    Munasinghe, K. C.
    Bowatta, B. G. C. T.
    Abayarathne, H. Y. R.
    Kumararathna, N.
    Maduwantha, L. K. A. H.
    Arachchige, N. M. P.
    Amarasinghe, Y. W. R.
    2ND INTERNATIONAL MERCON 2016 MORATUWA ENGINEERING RESEARCH CONFERENCE, 2016, : 36 - 41
  • [26] Development of liquid pumping devices using vibrating microchannel walls
    Ogawa, Junya
    Kanno, Isaku
    Kotera, Hidetoshi
    Wasa, Kiyotaka
    Suzuki, Takaaki
    SENSORS AND ACTUATORS A-PHYSICAL, 2009, 152 (02) : 211 - 218
  • [27] TOTALLY IMPLANTABLE VENTRICULAR ASSIST SYSTEM USING A VIBRATING FLOW PUMP
    NITTA, S
    YAMBE, T
    SONOBE, T
    NAGANUMA, S
    KAKINUMA, Y
    KOBAYASHI, S
    TANAKA, M
    MATSUKI, H
    ABE, K
    YOSHIZAWA, M
    KASAI, T
    HASHIMOTO, H
    ARTIFICIAL ORGANS, 1995, 19 (07) : 676 - 679
  • [28] Research and Development on X-ray Micro-CT System for MEMS
    Fu Jian
    Li Bin
    Zhou Zhenggan
    Wei Dongbo
    Zhou Xingyu
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 1947 - 1950
  • [29] Development of Pulse Control Type MEMS Micro Robot with Hardware Neural Network
    Okazaki, Kazuto
    Ogiwara, Tatsuya
    Yang, Dongshin
    Sakata, Kentaro
    Saito, Ken
    Sekine, Yoshifumi
    Uchikoba, Fumio
    PROCEEDINGS OF THE SIXTEENTH INTERNATIONAL SYMPOSIUM ON ARTIFICIAL LIFE AND ROBOTICS (AROB 16TH '11), 2011, : 938 - 941
  • [30] Performance evaluation and flow visualization of a MEMS based vaporizing liquid micro-thruster
    Cen, J. W.
    Xu, J. L.
    ACTA ASTRONAUTICA, 2010, 67 (3-4) : 468 - 482