Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation

被引:0
|
作者
Peter Bernhardt
Christoph Rodewald
Julia Seeger
Birgid Gonska
Dominik Buckert
Michael Radermacher
Vinzenz Hombach
Wolfgang Rottbauer
Jochen Wöhrle
机构
[1] University of Ulm,Department of Internal Medicine II
来源
Clinical Research in Cardiology | 2016年 / 105卷
关键词
Magnetic resonance imaging; Transcatheter aortic valve implantation;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:273 / 278
页数:5
相关论文
共 50 条
  • [1] Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation
    Bernhardt, Peter
    Rodewald, Christoph
    Seeger, Julia
    Gonska, Birgid
    Buckert, Dominik
    Radermacher, Michael
    Hombach, Vinzenz
    Rottbauer, Wolfgang
    Woehrle, Jochen
    CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (03) : 273 - 278
  • [2] Non-contrast Enhanced Magnetic Resonance Angiography is Superior to Contrast-enhanced Magnetic Resonance Angiography for Correct Aortic Sizing Before Transcatheter Aortic Valve Replacement: A Comparison to Multislice Computed Tomography
    Rodewald, Christoph
    Spiess, Jochen
    Brunner, Horst
    Walcher, Thomas
    Kummel, Andreas
    Rottbauer, Wolfgang
    Bernhardt, Peter
    CIRCULATION, 2012, 126 (21)
  • [3] Quantification of aortic valve calcification on contrast-enhanced CT of patients prior to transcatheter aortic valve implantation
    Eberhard, Matthias
    Mastalerz, Monika
    Frauenfelder, Thomas
    Tanner, Felix C.
    Maisano, Francesco
    Nietlispach, Fabian
    Seifert, Burkhardt
    Alkadhi, Hatem
    Thi Dan Linh Nguyen-Kim
    EUROINTERVENTION, 2017, 13 (08) : 921 - 927
  • [4] Pre-Procedural Assessment of the Femoral Access Route for Transcatheter Aortic Valve Implantation: Comparison of a Non-Contrast Time-of-Flight Magnetic Resonance Angiography Protocol with Contrast-Enhanced Dual-Source Computed Tomography Angiography
    Brado, Johannes
    Breitbart, Philipp
    Hein, Manuel
    Pache, Gregor
    Schmitt, Ramona
    Hein, Jonas
    Apweiler, Matthias
    Soschynski, Martin
    Schlett, Christopher
    Bamberg, Fabian
    Neumann, Franz-Josef
    Westermann, Dirk
    Krauss, Tobias
    Ruile, Philipp
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
  • [5] Non-contrast-enhanced magnetic resonance angiography: techniques and applications
    Blankholm, Anne Dorte
    Ringgaard, Steffen
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2012, 10 (01) : 75 - 88
  • [6] Multislice computed tomography in the selection of candidates for transcatheter aortic valve implantation
    de Morais, Gustavo Pires
    Bettencourt, Nuno
    Silva, Guida
    Ferreira, Nuno
    Sousa, Olga
    Caeiro, Daniel
    Rocha, Joao
    Carvalho, Monica
    Leite, Daniel
    Braga, Pedro
    Fonseca, Conceicao
    Gama, Vasco
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2011, 30 (09) : 717 - 726
  • [7] Demonstration of cardiac involvement of sarcoidosis by contrast-enhanced multislice computed tomography and delayed-enhanced magnetic resonance imaging
    Kanao, S
    Tadamura, E
    Yamamuro, M
    Kubo, S
    Kimura, T
    Kita, T
    Togashi, K
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (06) : 745 - 748
  • [8] The feasibility of relaxation-enhanced angiography without contrast and triggering for preprocedural planning of transcatheter aortic valve implantation
    Wang, Rui
    Liu, Xinmin
    Yao, Jing
    Schoepf, U. Joseph
    Griffith, Joseph
    Wang, Jiayang
    Lian, Jianxiu
    Jiang, Ke
    Song, Guangyuan
    Xu, Lei
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [9] Prosthesis sizing for transcatheter aortic valve implantation - Comparison of three dimensional transesophageal echocardiography with multislice computed tomography
    Husser, Oliver
    Holzamer, Andreas
    Resch, Markus
    Endemann, Dierk H.
    Nunez, Julio
    Bodi, Vicente
    Schmid, Christof
    Riegger, Guenter A. J.
    Goessmann, Holger
    Hamer, Okka
    Stroszczynski, Christian
    Luchner, Andreas
    Hilker, Michael
    Hengstenberg, Christian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 3431 - 3438
  • [10] Comparison of multislice computed tomography findings between bicuspid and tricuspid aortic valves before and after transcatheter aortic valve implantation
    Watanabe, Yusuke
    Chevalier, Bernard
    Hayashida, Kentaro
    Leong, Tora
    Bouvier, Erik
    Arai, Takahide
    Farge, Arnaud
    Hovasse, Thomas
    Garot, Philippe
    Cormier, Bertrand
    Morice, Marie-Claude
    Lefevre, Thierry
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (02) : 323 - 330