Detection of glutathione based on MnO2 nanosheet-gated mesoporous silica nanoparticles and target induced release of glucose measured with a portable glucose meter

被引:0
作者
Qingqing Tan
Ruirui Zhang
Rongmei Kong
Weisu Kong
Wenzhi Zhao
Fengli Qu
机构
[1] Qufu Normal University,College of Chemistry and Chemical Engineering
[2] Chinese Academy of Sciences,Beijing Key Laboratory of Ionic Liquids Clean Process, Key Laboratory of Green Process and Engineering, Institute of Process Engineering
来源
Microchimica Acta | 2018年 / 185卷
关键词
MnO; nanosheets; Mesoporous silica; Personal glucose meter; Glutathione; Portable detection; Target induced release;
D O I
暂无
中图分类号
学科分类号
摘要
The authors describe a novel method for the determination of glutathione (GSH). Detection is based on target induced release of glucose from MnO2 nanosheet-gated aminated mesoporous silica nanoparticles (MSNs). In detail, glucose is loaded into the pores of MSNs. Negatively charged MnO2 nanosheets are assembled on the MSNs through electrostatic interactions. The nanosheets are reduced by GSH, and this results in the release of glucose which is quantified by using a commercial electrochemical glucose meter. GSH can be quantified by this method in the 100 nM to 10 μM concentration range, with a 34 nM limit of detection.
引用
收藏
相关论文
共 193 条
[1]  
SC L(1999)Regulation of hepatic glutathione synthesis: current concepts and controversies FASEB J 13 1169-1183
[2]  
Lu SC(2009)Regulation of glutathione synthesis Mol Asp Med 30 42-59
[3]  
Estrela JM(2006)Glutathione in cancer biology and therapy Crit Rev Clin Lab Sci 43 143-181
[4]  
Ortega A(1997)Glutathione deficiency is associated with impaired survival in HIV disease Proc Natl Acad Sci 94 1967-1972
[5]  
Obrador E(2003)The importance of glutathione in human disease Biomed Pharmacother 57 145-155
[6]  
Herzenberg LA(1980)High-performance liquid chromatography analysis of nanomole levels of glutathione, glutathione disulfide, and related thiols and disulfides Anal Biochem 106 55-62
[7]  
De Rosa SC(2013)Centri-voltammetric determination of glutathione Microchim Acta 180 93-100
[8]  
Dubs JG(2015)Chemiluminescence of carbon dots induced by diperiodato-nicklate (IV) in alkaline solution and its application to a quenchometric flow-injection assays of paracetamol, L-cysteine and glutathione Microchim Acta 182 1071-1077
[9]  
Roederer M(2013)Detection of cellular glutathione and oxidized glutathione using magnetic-plasmonic nanocomposite-based “turn-off” surface enhanced Raman scattering Anal Chem 85 9221-9228
[10]  
Anderson MT(2011)Enhanced screening of glutathione-trapped reactive metabolites by in-source collision-induced dissociation and extraction of product ion using UHPLC-high resolution mass spectrometry Anal Chem 83 9516-9523