Label-free electrochemical immunoassay of carcinoembryonic antigen in human serum using magnetic nanorods as sensing probes

被引:2
作者
Xiaohong Fu
Jinyue Wang
Na Li
Li Wang
Lan Pu
机构
[1] Yibin University,School of Chemistry and Chemical Engineering
来源
Microchimica Acta | 2009年 / 165卷
关键词
Magnetic nanorods; Carcinoembryonic antigen; Potentiometric immunosensor; Label-free;
D O I
暂无
中图分类号
学科分类号
摘要
A new potentiometric immunoassay protocol for the determination of carcinoembryonic antigen (CEA) in human serum was designed by using a novel transparent immunoaffinity reactor. To construct such an affinity reactor, Fe3O4 nanorods with average diameter of 40 nm and length of 1.0 μm were initially synthesized through hydrolysis of FeCl3 and FeSO4 in the urea solution, and then the synthesized nanorods were used as the immobilized affinity support for the conjugation of anti-CEA antibodies (bionanorods). With an external magnet, the magnetic bionanorods were attached to the surface of a self-made carbon paste electrode. The performance and factors influencing the immunosensors were evaluated. Under optimal conditions, the binding of CEA in the samples onto the immobilized anti-CEA changed the potential response, a dynamic range from 1.5 to 80 ng·mL−1, and a detection limit of 0.9 ng·mL−1 CEA (at 3σ). The immunosensors show good precision, high sensitivity, acceptable stability and reproducibility. The CEA concentrations of the clinical serum specimens assayed by the immunosensor show consistent results in comparison with those obtained by commercially available enzyme-linked immunosorbent assay.
引用
收藏
页码:437 / 442
页数:5
相关论文
共 78 条
[1]  
Kojima R(2009)Integration of immunoassay into extended nanospace Microchim Acta 164 307-undefined
[2]  
Mawatari K(2009)Antibody-functionalized magnetic nanoparticles for electrochemical immunoassay of α-1-fetoprotein in human serum Microchim Acta 164 231-undefined
[3]  
Renberg B(2008)Development of a myoglobin impedimetric immunosensor based on mixed self-assembled monolayer onto gold Microchim Acta 160 447-undefined
[4]  
Tsukahara T(2008)Determination of HIgG and anti-HIgG using a single potentiometric immunosensor and two different “competitive methods”: application to the analysis of globulin G in human serum Sens Actu B 130 520-undefined
[5]  
Kitamori T(2008)Label-free detection of bisphenol A using a potentiometric immunosensor Electroanalysis 20 30-undefined
[6]  
Wang L(2008)A renewable potentiometric immunosensor based on Fe Electroanalysis 20 881-undefined
[7]  
Gan X(2008)O TRAC-Trend Anal Chem 27 568-undefined
[8]  
Billah M(2008) nanoparticles immobilized anti-IgG Biosens Bioelectron 24 729-undefined
[9]  
Hays H(2009)Electrochemical analysis with nanoparticle-based biosystems Microchim Acta 164 299-undefined
[10]  
Millner P(2007)Three-dimensional interdigitated electrode array as a transducer for label-free biosensor Biosens Bioelectron 22 3080-undefined