Simultaneous polarographic determination of 2-nitrophenol and 4-nitrophenol by differential pulse polarography method and support vector regression

被引:0
作者
Karim Asadpour-Zeynali
Payam Soheili-Azad
机构
[1] University of Tabriz,Department of Analytical Chemistry, Faculty of Chemistry
来源
Environmental Monitoring and Assessment | 2012年 / 184卷
关键词
Support vector regression; Simultaneous determination; Differential pulse polarograhy; 2-Nitrophenol; 4-Nitrophenol;
D O I
暂无
中图分类号
学科分类号
摘要
A differential pulse polarography (DPP) for the simultaneous determination of 2-nitrophenol and 4-nitrophenol was proposed. It was found that under optimum experimental conditions (pH = 5, scan rate = 5 mV/s, pulse amplitude = −50 mV), 2-nitrophenol and 4-nitrophenol had well-defined polarographic reduction waves with peak potentials at −317 and −406 mV, respectively. In the mixture of two compounds overlapping polarographic peaks were observed. In this study, support vector regression (SVR) was applied to resolve the overlapped polarograms. Furthermore, a comparison was made between the performance of SVR and partial least square (PLS) on data set. The results demonstrated that SVR is a better well-performing alternative for the analysis and modeling of DPP data than the commonly applied PLS technique. The proposed method was used for the determination of 2-nitrophenol and 4-nitrophenol in industrial waste water.
引用
收藏
页码:1089 / 1096
页数:7
相关论文
共 95 条
[1]  
Asadpour-Zeynali K(2010)Simultaneous polarographic determination of isoniazid and rifampicin by differential pulse polarography method and support vector regression Electrochimica Acta 55 6570-6576
[2]  
Soheili-Azad P(1999)Determination of toxic nitrophenols in the atmosphere by high-performance liquid chromatography Journal of Chromatography A846 277-281
[3]  
Belloli R(2001)Electroanalytical determination of acid phosphatase activity by monitoring p-nitrophenol Analytica Chimica Acta 441 207-214
[4]  
Barletta B(1996)Liquid chromatography/electrochemical detection of phenols at a Poly[Ni-(Protoporphyrin IX)] chemically modified electrode Analytica Chimica Acta 336 195-199
[5]  
Bolzacchini E(2006)Validation of a HPLC method for the determination of p-nitrophenol hydroxylase activity in rat hepatic microsomes Journal of Chromatography B834 199-203
[6]  
Meinardi S(2004)Voltammetric characterisation of the radical anions of 4-nitrophenol, 2-cyanophenol and 4-cyanophenol in Journal of Electroanalytical Chemistry 561 53-65
[7]  
Orlandi M(2000)-dimethylformamide electrogenerated at gold electrodes Journal of Agricultural and Food Chemistry 48 4508-4513
[8]  
Rindone B(2001)Derivative voltammetric direct simultaneous determination of nitrophenol isomers at a carbon nanotube modified electrode Talanta 54 115-123
[9]  
Calvo-Marzal P(2003)Voltammetric determination of 4-nitrophenol at a sodium montmorillonite-anthraquinone chemically modified glassy carbon electrode Analytical and Bioanalytical Chemistry 75 703-707
[10]  
Rosatto SS(1993)Simultaneous determination of 2-nitrophenol and 4-nitrophenol based on the multi-wall carbon nanotubes Nafion-modified electrode Analytica Chimica Acta 248 13-19